1. Unscrew the 4 screws and remove the cover.
2. Loosen the captive screw to free the sensor from the mounting plate.
3. Using the included screws, mount the mounting plate to the wall.
4. Use the breakout and cable gland at the bottom of the sensor to run the
wires.
5. Remove the terminal block using longnose pliers and wire the unit
according to the wiring diagram above.
6. Hang the sensor back on to the plate, and use the captive screw to
secure it in place.
7. Re-attach the cover, and use the included small screws to secure it.
8. Attach the hood to the top of the sensor.
TO MAKE THE PHOTO EYE WORK WITH N.O.
Take the following steps to remove the 10K resistor. This only removes
the 10K resistor, the photo eye is still UL certified.
Removing the 10K resistor
STEP 1:
Remove 4 screws as shown.
STEP 2:
Cut the R42 resistor on the
board as shown.
BEFORE
AFTER
This process must be followed for pre-2016 legacy operators that
require normally open.