9.1.1.2
ID parameters
ID parameter determines time period of the pulse length to trigger the alarm. The
pulse time can be from 0,5 seconds to 9999 seconds. The default time is 0,5
seconds when the parameter value is 0.
Parameter is in seconds.
9.1.1.3
DD parameters
This parameter is used to define the delay between the time that alarm input is
trigged and the time that alarm is reported.
Parameter is in seconds.
9.1.1.4
Table of parameters
Name
Comment
IN1
Mode of operation for input 1
ID1
Input time integration delay on input 1
DD1
Time delay for alarm reporting on input 1
Table 1: IN, ID and DD parameters
Example:
♦
Direct programming on the SIM card
ICE-LOCK PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name
Number
Description
IN1
0
Alarm activated by connecting to GND
ID1
10
Input 1 has to be valid for 10 second to trigger
the alarm
DD1
15
Reporting of the alarm on input 1 is delayed by
15s
Table 2: IN, ID, DD parameters example
♦
Remote programming by SMS
;IN1=0;ID1=10;DD1=15;