background image

 

ICE-­‐LOCK   

GSM   Code   Lock   access   control   unit   

   

   

 

   

INSTALLATION   MANUAL   

 

 

 

Содержание ICE-LOCK

Страница 1: ...ICE LOCK GSM Code Lock access control unit INSTALLATION MANUAL...

Страница 2: ...CLIP 26 9 9 SPECIAL SMS COMMANDS 28 10 PRINT OUT OF THE PARAMETERS 30 10 1 RECEIVE ALL PARAMETERS PALL 30 10 2 CHECK SW REVISION PSW 30 10 3 CHECK SIGNAL QUALITY PSQ 30 10 4 RECEIVE TELEPHONE NUMBERS...

Страница 3: ...LOCK Connection diagram 11 Figure 2 Input Connection diagram 14 Figure 3 Output Connection diagram 16 Tables Table 1 IN ID and DD parameters 14 Table 2 IN ID DD parameters example 14 Table 3 Remote al...

Страница 4: ...Table 17 CLIP parameters 27 Table 18 CLIP parameters example 27 Table 19 LOG parameters 27 Table 20 LOG parameters example 28 Table 21 SMS commands 29 Table 22 SMS commands example 29 Table 23 ICE LO...

Страница 5: ...ible to interference which could affect performance SWITCH OFF IN HOSPITALS Follow any restrictions Switch the unit off near medical equipment SWITCH OFF IN AIRCRAFT Follow any restrictions Wireless d...

Страница 6: ...with CodeLock keypad which can open automated electric gates You can dial the number of the ICE LOCK unit free of charge Caller ID or type your unique entry code into CodeLock keypad When the call is...

Страница 7: ...put 1 output relay supported Up to 50 telephone numbers for CLIP support Programming by USB on the ICE LOCK Programming by SMS command all parameters including the PIN access codes Anti tampering inpu...

Страница 8: ...d OFF when you insert the SIM Connect the external antenna to antenna connector Connect input and output to ICE LOCK Connect power cable to ICE LOCK device Connect device to source power supply voltag...

Страница 9: ...of the GSM signal from 1 to 5 LED flashes 1 is weak signal 5 is excellent signal Yellow LED LED2 Short flashing indicates that the GSM module is ON but it is not yet connected on the GSM network Afte...

Страница 10: ...ng this SMS to ICE LOCK all programmed parameters and numbers are cleared SDCLR After the command is received by the device all configuration parameters on the SIM card including the SMS are deleted T...

Страница 11: ...E LOCK please take a look at connection diagram very carefully Figure 1 ICE LOCK Connection diagram VERY IMPORTANT Do not use the 12V AUX power output for electric lock driving You can use it to power...

Страница 12: ...program ICE LOCK directly with the use of USB connection on the device You can program all parameters except PIN access codes Programming of PIN access codes is not supported yet on EasySet SW you can...

Страница 13: ...e triggering of the alarm inputs 9 1 1 1 IN parameters Alarm and reset input can be triggered in 4 different ways The status of the input can either be normal closed N C or normal open N O with positi...

Страница 14: ...and the time that alarm is reported Parameter is in seconds 9 1 1 4 Table of parameters Name Comment IN1 Mode of operation for input 1 ID1 Input time integration delay on input 1 DD1 Time delay for al...

Страница 15: ...hone numbers on TN list 9 1 2 3 Table of parameters Name Comment TN1 1st telephone number TN2 2nd telephone number TN3 3rd telephone number TN4 4th telephone number TN5 5th telephone number LN1 Input...

Страница 16: ...ibility to report alarms from inputs and any other events locally via 1 output The behavior is defined using next parameters 9 2 1 OS parameter ICE LOCK device has 1 dedicated relay supported outputs...

Страница 17: ...e Direct programming on the SIM card ICE LOCK PROGRAMMING TABLE SIM CARD PHONE BOOK Name Number Description OS1 14 Mono stable pulse mode 14s pulse OD1 1 Input 1 activates output 1 OP1 1 Output 1 inve...

Страница 18: ...PIN access codes example Remote programming by SMS PIN1 3369 PIN12 1234 NOTE PINx access codes must be 4 digits long and must start with number greater or equal 1 9 3 3 Using the keypad for activating...

Страница 19: ...remote controlling is possible from any phone Name value Comment SL 0 All calls and SMS are accepted SL 1 Only number stored under parameter TN1 has access to unit SL 2 Numbers stored under parameter...

Страница 20: ...or SIM card validity is near to expiration NOTE For support of different GSM providers contact support 9 5 1 Programming prepaid card credit and validity string To be able to support credit and time v...

Страница 21: ...m the GSM provider CREF Pars string for the replays received from CC1 number CVODA Pars string for the replays received from CC2 number CTIM Pars string for the replays received from CC3 number 9 5 1...

Страница 22: ...4 9 6 SET UP PARAMETERS Different parameters are used to support versatile functionality of ICE LOCK 9 6 1 UDC parameter Parameter is used to synchronise ICE LOCK clock to GSM network clock User must...

Страница 23: ...ional MCC MNC codes can be acquired at http en wikipedia org wiki Mobile_Network_Code 9 6 4 ARST parameter ARST parameter defines periodic of auto restart time in hours of the ICE LOCK device 9 6 5 AD...

Страница 24: ...umber TST SMS test time out MNF Manual GSM provider selection ARST Time out control for automatic system restart ADF Auto dial functionality Call TN1 LNG Language selection BUZ Buzzer control Table 13...

Страница 25: ...NG parameter The message is stored in the SIM phone book so you should add any number for correct operation 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 0 U S E R L O C A T I O N 1 I N P U T 1 NOTE Message...

Страница 26: ...olled by the CLIP functionality 9 8 3 CLPI parameter This parameter if set is a precondition for CLIP function to control the output The input define by the CLPI parameter must be active for CLIP func...

Страница 27: ...Description CLPEN 1 Enable CLIP functionality CLPOU 2 CLIP control output 2 CLPI 0 No input activation condition CLP1 040414414 CLIP number 1 CLP2 042340880 CLIP number 2 Table 18 CLIP parameters exa...

Страница 28: ...G parameters example Remote programming by SMS LOGN 5 LOGI 0 ALC 1 9 9 SPECIAL SMS COMMANDS These commands can only be issued only over SMS message and are used to control some special functions of IC...

Страница 29: ...1 SDCLR Delete all SIM content LCRL Delete log on ICE LOCK device MRES Manual reset of GSM module SSRES Manual reset of ICE LOCK device Table 21 SMS commands Example Remote programming by SMS SMS com...

Страница 30: ...his command to ICE LOCK you receive SMS messages with current SW version running on ICE LOCK device PSW 10 3 CHECK SIGNAL QUALITY PSQ By sending this command to ICE LOCK you receive SMS messages with...

Страница 31: ...VALUE POD By sending this command to ICE LOCK you receive SMS message with all currently programmed direct output links POD 10 9 RECEIVE DELAY BEFORE DIAL VALUE PDD By sending this command to ICE LOCK...

Страница 32: ...ding this command to ICE LOCK you receive SMS message with all currently programmed credit parse parameters PCREF 10 15 RECEIVE CREDIT CHECK TELEPHONE NUMBERS PCN By sending this command to ICE LOCK y...

Страница 33: ...puts state PORC 10 19 MANUAL GSM MODULE RESTART MRES By sending this command to ICE LOCK shuts down GSM module and after a few second it switches the power of the GSM module ON again The unit reboots...

Страница 34: ...ICE LOCK INSTALLATION MANUAL Page 34 10 22 RECEIVE ICE LOCK LOG By sending this command to ICE LOCK you receive SMS message with log on ICE LOCK device PLOG...

Страница 35: ...TN1 0 TN2 0 If you would like to enter telephone numbers in to ICE LOCK you can use the following example TN1 040713470 TN2 38643364850 If you would like to receive confirmation SMS write before SMS c...

Страница 36: ...INSTALLATION MANUAL Page 36 Send SMS command to the ICE LOCK and in a few seconds you will receive SMS message from it The sentence of the SMS must be the same as the one you have sent to the ICE LOC...

Страница 37: ...tel numbers LN5 Empty NAC link to tel numbers LN6 Empty LOG status link to tel numbers ID1 0 Input 1 delay filter on input DD1 0 Input 1 delay before dialing RAN 0 Auto answer ring number SL 0 Securit...

Страница 38: ...text contact support CVODA DISPON E Parse text contact support CLPEN 1 Enable CLIP functionality CLPOU 1 Control output pin when CLIP event CLPI 0 Clip input condition CLPRI 0 Clip restore function C...

Страница 39: ...rameters PDD Prints DDx parameters PSL Prints SL parameter POS Prints OSx parameters P Prints x parameters PPA Prints various setup parameters PCLP Prints CLIP parameters PLOG Prints log of the ICE LO...

Страница 40: ...nsumption transmitting mode 300mA Current consumption idle mode with illuminated keypad 180mA Quad band GSM module 850 900 1800 1900 MHz PCB dimensions 82 75 mm Unit dimensions 156 116 61 mm External...

Страница 41: ...E GOODS EXPRESS OR IMPLIED INCLUDING WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE BUYER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS EXPRESS OR IMPLI...

Отзывы: