background image

Problem                                           Possible Cause                                                                        Solution

Door does not lock

No power

Poor contact between electromagnet and 

armature plate

Low voltage or incorrect voltage setting

A secondary diode was installed across 

the electromagnetic lock

Misalignment between the armature plate

and electromagnetic lock

Make sure the wires are connected properly
Check that the power supply is connected and works properly
Make sure the lock switch is wired correctly (N.C.)

Make sure if the armature plate is deformed

Make sure the contact surfaces of the electromagnet and armature plate are clean 

and free from dust

Make sure the armature plate and electromagnetic lock are aligned correctly

Make sure if the rubber washer was used between magnet lock and armature plate

Ensure the electromagnet lock is set for the correct voltage.

Check for proper voltage at the electromagnetic locks input. If low, determine if the 

correct wire gauge is being used to prevent excessive voltage drop.

Remove any diode installed across the magnet for "spike" 

suppression. (The magnet is  fitted with a metal oxide varistor to prevent back EMF)

Low holding force

Sensor output is not functioning

Trouble Shooting

N.O.

COM.

N.C.

Mag Power Input

Sensor Input

Orange: N.O.

White: Com

Brown: N.C.

  Timer Adjustment

1~80 seconds

LED indicator

GREEN: Open

RED : Locked

NO LED: No power

Control Device N.C. contact or

Access Relay

Bond sensor output

N.C. contact output: open status

N.O. contact output: locked status

Models: 

Door Status Sensor (optional)

Door Status Sensor indicates the door is in an open 

or closed status.

Models: 

Buzzer Alarm (on the reverse)
Door Held Open Alarm is an auditory feedback for users.

Alarm sounds when the door is not closed for over a specified

time limit. VR timer (Timer Adjustment) is adjustable from

1 to 80 seconds.

12 or 24V

Auto
switchable

(Available for GEM-800MBZ & GEM-1200MBZ)

Relock time delay (Optional)

Ensures the automatic lock mode works after the door is

closed properly and it can be adjusted from 1 to 80 seconds.

Connecting Diagram

GEM-600MDS, GEM-800MDS, GEM-1200MDS

GEM-D600MDS, GEM-D800MDS, GEM-D1200MDS

GEM-600M, GEM-800M, GEM-1200M

GEM-D600M, GEM-D800M, GEM-D1200M

GEM-600M, GEM-800M, GEM-1200M

GEM-D600M, GEM-D800M, GEM-D1200M

GEM-D800MBZ & GEM-D1200MBZ)