THE LED INDICATORS
MAINS (AMBER)
This is a status indicator. It flashes during standby and other indica�ons in synchroniza�on with
the pacifier tones. See the chart of LED indica�on signals below for the details.
DOOR (GREEN)
It lights up in green while output 1 is ac�ve (The door is open).
INHIBIT (RED)
It lights up while output 1 is inhibited; including manually inhibited with Super User Code or due
to False Code Lock-up se�ng in Loca�on 70.
BACK LIGHTING
The keypad is in dim back ligh�ng during the standby period. It gets brighter for 10 seconds on each
key bu�on press, which indicates the allowable �me for succeeding code entry. The previous codes
will be cancelled if no code is entered within 10 seconds.
THE PACIFIER TONES & THE LED INDICATING SIGNALS
The built-in buzzer and the MAINS LED indicator give the following tones and signals for opera�on
status:
NOTE:
*
All Pacifier Tones can be enabled or disabled through programming op�ons at Loca�on 83.
**
The Output Ac�va�on Beep can be enabled or disabled through programming op�ons at Loca�on 81.
STATUS
TONES
*
LED SIGNALS
1. In programming mode
---
1 Beep
2 Beeps
5 Beeps
Continuous Beeps
---
1 second Long Beep **
ON
1 Flash
2 Flashes
5 Flashes
Continuous Flashes
1 Flash in 2 seconds interval
---
2. Successful key entry
3. Successful code entry
4. Unsuccessful code entry
5. DAP jumper not replaced
6. In standby mode
7. Output relay activated
DRY CONTACT
A dry contact means that no electricity is connected to it. It is prepared for free connec�ons. The
Relay Output contacts provided in this keypad system are dry contacts.
N.C.
Normally Closed, the contact is closed circuit at normal status. It is open circuit when ac�ve.
N.O.
Normally Open, the contact is open circuit at normal status. It is closed circuit when ac�ve.
TRANSISTOR OPEN COLLECTOR OUTPUT
An open collector output is equivalent to a Normally Open (N.O.) contact referring to ground
similar to a relay contact referring to ground. The transistor is normally OFF, and its output
switches to ground (-) when ac�ve. The open collector can only provide switching func�on for
small power but it is usually good enough for controlling of an alarm system. The Duress,
Inter-lock and Key Ac�ve/Alarm Outputs of the keypad are open collector outputs.
OPEN COLLECTOR
OUTPUT ----
Output switches to
ground when activated
N.O. CONTACT
OUTPUT ----
Output switches to
ground when activated
EQUIVALENT
●
●
●
●
●
●
●
AUXILIARY INFORMATION