Fiber Cable 

Bit

 

Error

 

Rate:

    

 

 

<10

9

 

Single

 

mode

 

fiber

 

(recommended):

  

9

 μ

m

 

Multimode

 

fiber

 

(recommended):

  

62.5/125

 μ

m

 

Multimode

 

fiber

 

(optional):

  

 

100/140,

 

85/140,

 

50/125

 μ

m

 

 

E

100BTX

FX

06

  

 

 

1300

 

nm

 

multimode

 

Fiber

 

Optic

 

Transmitter

 

Power:

   

min:

 ‐

19.0

 

dBm

   

max:

 ‐

14.0

 

dBm

 

Fiber

 

Optic

 

Receiver

 

Sensitivity:

   

min:

 ‐

30.0

 

dBm

   

max:

 ‐

14.0

 

dBm

 

Link

 

Budget:

  

 

 

 

11.0

 

dbm

 

 

E

100BTX

FX

06(SC)

 

&

 

(LC)

  

 

1300

 

nm

 

multimode

 

Fiber

 

Optic

 

Transmitter

 

Power:

   

min:

 ‐

19.0

 

dBm

   

max:

 ‐

14.0

 

dBm

 

Fiber

 

Optic

 

Receiver

 

Sensitivity:

   

min:

 ‐

30.0

 

dBm

   

max:

 ‐

14.0

 

dBm

 

Link

 

Budget:

  

 

 

 

11.0

 

dbm

 

 

E

100BTX

FX

06(SM)

    

 

1310

 

nm

 

single

 

mode

 

Fiber

optic

 

Transmitter

 

Power:

    

min:

 ‐

15.0

 

dBm

   

max:

 ‐

8.0

 

dBm

 

Fiber

optic

 

Receiver

 

Sensitivity:

   

min:

 ‐

31.0

 

dBm

   

max:

 ‐

8.0

 

dBm

 

Link

 

Budget:

  

 

 

 

16.0

 

dbm

 

 

E

100BTX

FX

06(SMLC)

   

 

1310

 

nm

 

single

 

mode

 

Fiber

optic

 

Transmitter

 

Power:

    

min:

 ‐

15.2

 

dBm

   

max:

 ‐

8.0

 

dBm

 

Fiber

optic

 

Receiver

 

Sensitivity:

   

min:

 ‐

32.5

 

dBm

   

max:

 ‐

3.0

 

dBm

 

Link

 

Budget:

  

 

 

 

17.3

 

dbm

 

 

The

 

fiber

 

optic

 

transmitters

 

on

 

this

 

device

 

meet

 

Class

 

I

 

Laser

 

safety

 

requirements

 

per

 

IEC

825/CDRH

 

standards

  

and

 

comply

 

with

 

21

 

CFR1040.10

 

and

 

21CFR1040.11.

 

 

Содержание E-100BTX-FX-06

Страница 1: ...onverter 6 Operation 6 Status LEDs 6 Auto Negotiation 6 Pause Control 6 Auto MDI MDIX 6 Active Link Pass Through ALPT 7 Far End Fault 8 Specifications 8 Cable Specifications 8 Technical Specifications...

Страница 2: ...20 km 12 4 miles Typical maximum cable distance Actual distance depends on the physical characteristics of the network installation For more information see https www transition com Accessories Access...

Страница 3: ...Transition Networks E 100BTX FX 06 User Guide 33791 Rev A http www transition com Page 3 of 13 Family Portrait...

Страница 4: ...IP Switch The 4 position DIP switch is located on the side of the media converter Use a small flat blade screwdriver or a similar tool to set the recessed switches 1 Auto Negotiation Up Enables Auto N...

Страница 5: ...tor to the female RX port 3 Connect the fiber cables to the other device another media converter Ethernet Switch etc as described Connect the male TX cable connector to the female RX port Connect the...

Страница 6: ...is being received on the copper link RXF Receive Fiber Flashing A signal is being received on the fiber link Auto Negotiation When the Auto Negotiation feature is activated the media converter config...

Страница 7: ...is met Upon power up of the converter Upon losing Link on either the copper or fiber ports In the Diagnostic state the link for each of the media converter s ports can come up independently of each o...

Страница 8: ...3 and 4 Specifications The fiber optic cable physical characteristics must meet or exceed IEEE 802 3ae specification Cable Specifications The physical characteristics must meet or exceed IEEE 802 3 s...

Страница 9: ...ultimode Fiber Optic Transmitter Power min 19 0 dBm max 14 0 dBm Fiber Optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm Link Budget 11 0 dbm E 100BTX FX 06 SM 1310 nm single mode Fiber optic Trans...

Страница 10: ...cUL Listed Canada FCC Part 15 Class A EN 55032 2012 EN 55024 2010 Directive 2014 30 EU Low Voltage Directive 2014 35 EU IEC EN 60950 1 2006 A2 2013 2011 65 EU EN 50581 2012 CE Mark MTBF Greater than...

Страница 11: ...t Tech Support See Contact Us on page 18 below YES Proceed to step 3 3 Is the SDF LED signal detect fiber illuminated NO Check the fiber cables for proper connection Verify that the TX and RX cables o...

Страница 12: ...y US and Canada 1 800 260 1312 International 00 1 952 941 7600 Main Office tel 1 952 941 7600 toll free 1 800 526 9267 fax 952 941 2322 sales transition com techsupport transition com customerservice...

Страница 13: ...eses ist ein Ger t der Funkst rgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst rungen auftreten In diesem F ll is der Benutzer f r Gegenma nahmen verantwortlich Attenti...

Отзывы: