Installing

 

the

 

Fiber

 

Cable

 

1.

 

Locate

 

a

 

100Base

FX

 

compliant

 

fiber

 

cable

 

with

 

male,

 

two

stranded

 

TX

 

to

 

RX

 

connectors

 

installed

 

at

 

both

 

ends.

 

2.

 

Connect

 

the

 

fiber

 

cables

 

to

 

the

 

media

 

converter

 

as

 

described:

 

 

Connect

 

the

 

male

 

TX

 

cable

 

connector

 

to

 

the

 

female

 

TX

 

port.

 

 

Connect

 

the

 

male

 

RX

 

cable

 

connector

 

to

 

the

 

female

 

RX

 

port.

 

3.

 

Connect

 

the

 

fiber

 

cables

 

to

 

the

 

other

 

device

 

(

another

 

media

 

converter,

 

Ethernet

 

Switch,

 

etc.

)

 

as

 

described:

 

 

Connect

 

the

 

male

 

TX

 

cable

 

connector

 

to

 

the

 

female

 

RX

 

port.

 

 

Connect

 

the

 

male

 

RX

 

cable

 

connector

 

to

 

the

 

female

 

TX

 

port.

 

 

 

 

Installing

 

the

 

Copper

 

Cable

 

1.

 

Locate

 

a

 

100Base

TX

 

compliant

 

copper

 

cable

 

with

 

male,

 

RJ

45

 

connectors

 

installed

 

at

 

both

 

ends.

 

2.

 

Connect

 

the

 

RJ

45

 

connector

 

at

 

one

 

end

 

of

 

the

 

cable

 

to

 

the

 

RJ

45

 

port

 

on

 

the

 

media

 

converter.

 

3.

 

Connect

 

the

 

RJ

45

 

connector

 

at

 

the

 

other

 

end

 

of

 

the

 

cable

 

to

 

the

 

RJ

45

 

port

 

on

 

the

 

other

 

device

 

(

switch,

 

workstation,

 

etc.

).

 

 
 

 

 

Содержание E-100BTX-FX-06

Страница 1: ...onverter 6 Operation 6 Status LEDs 6 Auto Negotiation 6 Pause Control 6 Auto MDI MDIX 6 Active Link Pass Through ALPT 7 Far End Fault 8 Specifications 8 Cable Specifications 8 Technical Specifications...

Страница 2: ...20 km 12 4 miles Typical maximum cable distance Actual distance depends on the physical characteristics of the network installation For more information see https www transition com Accessories Access...

Страница 3: ...Transition Networks E 100BTX FX 06 User Guide 33791 Rev A http www transition com Page 3 of 13 Family Portrait...

Страница 4: ...IP Switch The 4 position DIP switch is located on the side of the media converter Use a small flat blade screwdriver or a similar tool to set the recessed switches 1 Auto Negotiation Up Enables Auto N...

Страница 5: ...tor to the female RX port 3 Connect the fiber cables to the other device another media converter Ethernet Switch etc as described Connect the male TX cable connector to the female RX port Connect the...

Страница 6: ...is being received on the copper link RXF Receive Fiber Flashing A signal is being received on the fiber link Auto Negotiation When the Auto Negotiation feature is activated the media converter config...

Страница 7: ...is met Upon power up of the converter Upon losing Link on either the copper or fiber ports In the Diagnostic state the link for each of the media converter s ports can come up independently of each o...

Страница 8: ...3 and 4 Specifications The fiber optic cable physical characteristics must meet or exceed IEEE 802 3ae specification Cable Specifications The physical characteristics must meet or exceed IEEE 802 3 s...

Страница 9: ...ultimode Fiber Optic Transmitter Power min 19 0 dBm max 14 0 dBm Fiber Optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm Link Budget 11 0 dbm E 100BTX FX 06 SM 1310 nm single mode Fiber optic Trans...

Страница 10: ...cUL Listed Canada FCC Part 15 Class A EN 55032 2012 EN 55024 2010 Directive 2014 30 EU Low Voltage Directive 2014 35 EU IEC EN 60950 1 2006 A2 2013 2011 65 EU EN 50581 2012 CE Mark MTBF Greater than...

Страница 11: ...t Tech Support See Contact Us on page 18 below YES Proceed to step 3 3 Is the SDF LED signal detect fiber illuminated NO Check the fiber cables for proper connection Verify that the TX and RX cables o...

Страница 12: ...y US and Canada 1 800 260 1312 International 00 1 952 941 7600 Main Office tel 1 952 941 7600 toll free 1 800 526 9267 fax 952 941 2322 sales transition com techsupport transition com customerservice...

Страница 13: ...eses ist ein Ger t der Funkst rgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst rungen auftreten In diesem F ll is der Benutzer f r Gegenma nahmen verantwortlich Attenti...

Отзывы: