Transition
Networks
SISTP10x0
‐
3xx
‐
LRT
Quick
Start
Guide
33732
Rev.
A
https://www.tranition.com
Page
2
of
2
Connect
PoE+
Ports
via
TP
Copper
Cable
The
Switch
also
provides
10/100/1000Base
‐
T.
Supported
cabling
:
PoE
per
IEEE
802.3af
PoE
supports
Cat
3
and
Cat
5.
PoE
per
IEEE
802.3at
PoE+
supports
Cat
5.
1.
Prepare
a
twisted
‐
pair
copper
cable.
2.
Connect
one
end
of
the
cable
to
the
Switch.
3.
Connect
the
other
end
of
the
cable
to
a
PD,
such
as
a
VoIP
phone.
Note
:
After
the
cable
is
properly
connected
at
both
ends,
the
Switch
SYS
LED
should
be
functional.
Grounding
After
the
Switch
is
mounted
and
connected,
the
front
panel
grounding
screw
can
be
used
for
grounding.
Grounding
and
wire
routing
help
limit
the
effects
of
noise
due
to
electromagnetic
interference
(EMI).
Run
the
ground
connection
from
the
ground
screw
to
the
grounding
surface
before
connecting
devices.
ATTENTION:
This
case
must
be
earth
grounded.
No
DC
input
may
be
earth
grounded.
Use
Isolated
Power
Supply.
Warning
:
Minimum
input
52
VDC.
Check
polarity
first!
Warning
and
Caution
‐
Proper
Installation
and
Operation
(English):
These
devices
are
open
‐
type
devices
that
are
to
be
installed
in
an
enclosure
only
accessible
with
the
use
of
a
tool,
suitable
for
the
environment.
This
equipment
is
suitable
for
use
in
Class
I,
Division
2,
Groups
A,
B,
C,
and
D
or
non
‐
hazardous
locations
only.
WARNING
–
EXPLOSION
HAZARD.
DO
NOT
DISCONNECT
WHILE
THE
CIRCUIT
IS
LIVE
OR
UNLESS
THE
AREA
IS
FREE
OF
IGNITIBLE
CONCENTRATIONS.
Avertissement
et
mise
en
garde
‐
Installation
et
fonctionnement
corrects
(français):
Ces
périphériques
sont
des
périphériques
de
type
ouvert
qui
doivent
être
installés
dans
un
enceinte
uniquement
accessible
à
l'aide
d'un
outil,
adapté
à
environnement.
Cet
équipement
peut
être
utilisé
dans
la
classe
I,
division
2,
groupes
A,
B,
C,
et
D
ou
des
emplacements
non
dangereux
seulement.
AVERTISSEMENT
‐
RISQUE
D'EXPLOSION.
NE
PAS
SE
DÉCONNECTER
LORSQUE
LE
CIRCUIT
EST
VIVANT
OU
À
MOINS
QUE
LA
ZONE
NE
SOIT
LIBRE
DE
CONCENTRATIONS
IGNIFIABLES.
Connecting
to
Power
Industrial
Power
Supplies
25104
and
25105
are
optional
accessories
(sold
separately).
See
the
Install
Guide.
After
the
Switch
is
mounted,
connected,
and
grounded,
use
t
he
Terminal
Block’s
DC
Power
Inputs
P1
and
P2.
Warning
:
connect
the
wires
to
the
terminal
block
before
plugging
power
into
the
Switch
product.
1.
Insert
the
negative/positive
DC
wires
into
the
V
‐
and
V+
terminals,
respectively.
2.
Tighten
the
wire
‐
clamp
screws
on
the
front
of
the
Terminal
Block
connector.
3.
Plug
the
Power
adapter
plug
into
AC
power
at
an
appropriate
AC
outlet.
4.
Check
the
SYS
LED.
If
it
is
ON,
the
power
connection
is
correct.
See
the
Install
Guide
for
adjusting
power
supply
output
voltage
(+V
ADJ)
and
LED
Descriptions.
These
devices
are
open
‐
type
devices
that
are
to
be
installed
in
an
enclosure
only
accessible
with
the
use
of
a
tool,
suitable
for
the
environment.
This
equipment
is
suitable
for
use
in
Class
I,
Division
2,
Groups
A,
B,
C,
and
D
or
non
‐
hazardous
locations
only.
“WARNING
–
EXPLOSION
HAZARD.
DO
NOT
DISCONNECT
WHILE
THE
CIRCUIT
IS
LIVE
OR
UNLESS
THE
AREA
IS
FREE
OF
IGNITIBLE
CONCENTRATIONS.
Temperature
code
(T
‐
Code)
–
T4.
Contact
Us
Technical
Support
:
Technical
support
is
available
24
‐
hours
a
day:
US
and
Canada:
1
‐
800
‐
260
‐
1312;
International:
00
‐
1
‐
952
‐
941
‐
7600.
Main
Office
tel:
+1.952.941.7600
|
toll
free:
1.800.526.9267
|
fax:
952.941.2322
|
|
Transition
Networks
|
10900
Red
Circle
Drive
|
Minnetonka,
MN
55343,
U.S.A.
https://www.transition.com