background image

 

18

 

Single Port Information 

 

Click the port on the Panel figure on the web interface directly. Then, the single port information 

window will show up and display the port current information. 

 

 

Port information interface 

 

 

Port Statistics 

 

The following information provides the current port statistic information 

 

Click 

Clear

  button to clean all counts 

 

 

Port Statistics Interface 

Содержание SISTM10xx-162-LR

Страница 1: ...SISTM10xx 162 LR T 6 10 100Base TX 2 100Base FX Industrial Managed Switch Installation Manual Rev 1 25 October 2007 ...

Страница 2: ...d and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by on...

Страница 3: ...g the Power Inputs 8 Wiring the Fault Alarm Contact 8 Wiring the Fault Alarm Contact 9 Mounting Installation 10 DIN Rail Mounting 10 Wall Mount Plate Mounting 11 Hardware Installation 11 Hardware Installation 12 Installation Steps 12 Network Application 13 X Ring Application 14 Coupling Ring Application 15 Dual Homing Application 15 Web Based Management 16 About Web based Management 16 Preparing f...

Страница 4: ...n 28 Power Alarm Configuration 29 IP Configuration 29 SNTP Configuration 30 IP Security 32 RSTP Configuration 32 System Configuration 33 Per Port Configuration 34 X Ring 35 QoS Configuration 37 IGMP 38 Security Manager 39 SNMP Configuration 40 System Options 41 Community strings 41 Trap Manager 41 Configuration Backup 41 TFTP Restore Configuration 41 TFTP Backup Configuration 42 TFTP Update Firmwa...

Страница 5: ...Save Configuration 44 Rate Control 44 System Log 45 System Log Configuration 45 Event Configuration 46 Troubles shooting 48 Technical Specification 49 ...

Страница 6: ...Wide range redundant power design DIN rail and wall mount design 2K MAC address table Web management GUI Per port supports 4 priority queues Provides Fiber link ability IEEE 802 3x flow control support o Flow control with full duplex o Back pressure with half duplex Support Class of service Support IGMP with Query mode for multi media application Supports ingress packet filter and egress rate limi...

Страница 7: ...0 150mm RoHS User manual CD DIN Rail Bracket attached on the switch One wall mount plate and six screws SISTM10xx 162 LRx DC Jack 2 0 150mm RoHS User Manual CD Wall Mount Plate Screws DIN Rail Bracket installed Compare the contents of the industrial switch with the standard checklist above If any item is damaged or missing please contact Transition Networks ...

Страница 8: ...135mm h x 105mm d Front Panel The Front Panel of the SISTM10xx 162 LRx Managed Industrial Switch is shown below Reset Button The reset button provides user a quick and easy way to restart and set the configuration back to default value Restart press the button for 2 seconds and release Set to factory default value press the button for 5 seconds and release The switch will ...

Страница 9: ...le port 1 Alarm 1 ON Enable port Alarm If the port s link fails the fault LED will light up OFF Disable port Alarm 2 ON Enable port Alarm If the port s link fails the fault LED will light up OFF Disable port Alarm 3 ON Enable port Alarm If the port s link fails the fault LED will light up OFF Disable port Alarm 4 ON Enable port Alarm If the port s link fails the fault LED will light up Grounding S...

Страница 10: ...the switch as the ring master in the X Ring group NOTE 1 When port alarm function is enabled the fault LED will on and Alarm relay will activity when port failure occurs 2 Please restart the switch after the X Ring DIP switch is set LED Indicators There are 7 diagnostic LEDs located on the front panel of the industrial switch They provide real time information of system and optional status The fol...

Страница 11: ...in full duplex mode Blinks Collision of Packets occurs in the port FDX COL Fiber Port Off The port in half duplex mode or no device attached Ports RJ 45 ports There are 6x 10 100Mbps auto sensing ports for 10Base T or 100Base TX devices connection The UTP ports will auto sense for 10Base T or 100Base TX connections Auto MDI MDIX means that the switch can connect to another switch or workstation wi...

Страница 12: ...1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD 2 Receive Data minus RD Transmit Data minus TD 3 Transmit Data plus TD Receive Data plus RD 6 Transmit Data minus TD Receive Data minus RD Straight Through Cable Schematic Cross Over Cable Schematic Fi...

Страница 13: ...lometers Fiber segment using multi mode connector type must use 50 or 62 5 125 um multi mode fiber cable User can connect two devices up to 2Km distances Wiring the Power Inputs Please follow below steps to insert the power wire NOTE The wire range of terminal block is from 12 24 AWG ATTENTION This is a Class 1 Laser LED product Don t stare into the Laser LED Beam V V V V 1 Insert the positive and...

Страница 14: ...ailure or port link failure and form an open circuit And application example for the fault alarm contact as below NOTE The wire range of terminal block is from 12 24 AWG Fault Alarm Contact 24V DC Buzzer 24V Battery The open circuit will form when the power failure or port link failure The fault alarm device will send a warning signal to warn the user ex alarm sound or flash light Insert the wires...

Страница 15: ...ounting Installation DIN Rail Mounting The DIN Rail is screwed on the industrial switch when out of factory 1 First insert the top of DIN Rail into the track 2 Then lightly push the DIN Rail into the track ...

Страница 16: ...N Rail from the industrial switch loose the screws to remove the DIN Rail 2 Place the wall mount plate on the rear panel of the industrial switch 3 Use the screws to screw the wall mount plate on the industrial switch 4 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall 5 To remove the wall mount plate reverse steps above Screwing the wall mount pla...

Страница 17: ...n The power LED on the Industrial switch will light up Please refer to the LED Indicators section for meaning of LED lights 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection 6 Insert one side of RJ 45 cable category 5 into the Industrial switch Ethernet port RJ 45 port and another side of RJ 45 cable category 5 to the network devices Ethernet port RJ 45 port ex S...

Страница 18: ...Network Application This chapter provides some sample applications to help user to have more actual idea of industrial switch function application A sample application of the industrial switch is as below ...

Страница 19: ... the network system to recovery from network connection failure within 300ms or less and make the network system more reliable The X Ring algorithm is like as spanning tree protocol STP algorithm but it has faster recovery time than STP The following figure is a sample X Ring application ...

Страница 20: ...of coupling ring application Dual Homing Application Dual Homing function is to prevent a lost connection between X Ring group and upper level core switch Assign two ports to be the Dual Homing port that is backup port in the X Ring group The Dual Homing function only works when the X Ring function is active Each X Ring group only has one Dual Homing port NOTE In Dual Homing application architectu...

Страница 21: ...nagement Before to use web management install the industrial switch on the network and make sure that any one of PC on the network can connect with the industrial switch through the web browser The industrial switch default value of IP subnet mask username and password is as below IP Address 192 168 16 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 16 254 User Name root Password root System L...

Страница 22: ...e auto negotiation mode auto force Config means the value that user configured Actual means the current value of the port Speed Duplex Display port connection speed Config means the value that user configured Actual means the current value of the port Flow Control Display the flow control status is enable or disable in full mode Config means the value that user configured Actual is for the current...

Страница 23: ...directly Then the single port information window will show up and display the port current information Port information interface Port Statistics The following information provides the current port statistic information Click Clear button to clean all counts Port Statistics Interface ...

Страница 24: ...ble And then click Apply button to apply all configuration When user select the port user can see port current configure shows in below column Port Control interface Switch Setting Assigning the system name location and view the system information System Name Assign the name of switch The maximum length is 64 bytes System Description Display the description of switch Read only cannot be modified S...

Страница 25: ...y one specific port That is traffic goes in or out monitored ports will be duplicated into mirror port Port Mirroring Mode Set mirror mode Disable TX and Both The default value is Disable Analysis Port It means mirror port can be used to see all monitor port traffic User can connect mirror port to LAN analyzer or Netxray Monitor Port The ports user wants to monitor All monitor port traffic will be...

Страница 26: ...adcast domain which would allow you to isolate network traffic so only the members of the VLAN will receive traffic from the same members of VLAN Basically creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch However all the network devices are still plugged into the same switch physically The industrial switch supports port bas...

Страница 27: ...ed the VLAN tagging is ignored In order for an end station to send packets to different VLAN groups it itself has to be either capable of tagging packets it sends with VLAN tags or attached to a VLAN aware bridge that is capable of classifying and tagging the packet with different VLAN ID based on not only default PVID but also other information about the packet such as the protocol VLAN PortBase ...

Страница 28: ... VLAN group And then click Apply VLAN PortBase Add interface The VLAN group will list To view the another VLAN groups click Next Page To delete unwanted VLAN click Delete button To modify existing VLAN group press Edit button NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off ...

Страница 29: ...nagement Security In fact it can remote management that includes telnet SNMP and Web browse the switch only when the port of VLAN group ID is equal to the Management VLAN ID Fill the specific VLAN ID number in Management VLAN ID column and mark the check box and then click Apply button to enable the function For example the management VLAN ID is 101 the VLAN group ID 101 includes the port 1 2 and ...

Страница 30: ...25 Grouping the ports and click Add button 802 1q VLAN Add interface And then click Next then follow interface as below ...

Страница 31: ...frames without VLAN Tagged Port VLAN ID Configure port VID settings Port VLAN ID Enter the port VLAN ID And then click Apply To reset back to default value click Default button 802 1q VLAN Port VLAN ID interface NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off ...

Страница 32: ... function SMTP Server IP Address Set up the mail server IP address Authentication Mark the check box to enable and configure the email account and password for authentication Mail Account Set up the email account to receive the alert Ex johnadmin 123 com The email account must exist on the mail server which user had set up in SMTP Server IP Address column Password The email account password Confir...

Страница 33: ...ystem will send out the alert to the dedicate SMTP server SMNP Authentication Failure When the SNMP authentication fail the system will send out the alert to the dedicate SMTP server X Ring topology change When the X Ring topology has changed the system will send out the alert to dedicate SMTP server Port event selection Select the per port events Per port has 3 selections Link UP Link Down and Li...

Страница 34: ...er click Apply button a popup dialog show up It is to inform the user that when the DHCP client is enabling the current IP will lose and user should find the new IP on the DHCP server To cancel the enabling DHCP client function click cancel IP Address Assign the IP address that the network is using If DHCP client function is enabling and then user don t need to assign the IP address And the networ...

Страница 35: ...different location time zone for the reference User also can drag down the list to find the time zone user want it Local Time Zone Conversion from UTC Time at 12 00 UTC November Time Zone 1 hour 11am Oscar Time Zone 2 hours 10 am ADT Atlantic Daylight 3 hours 9 am AST Atlantic Standard EDT Eastern Daylight 4 hours 8 am EST Eastern Standard CDT Central Daylight 5 hours 7 am CST Central Standard MDT...

Страница 36: ... Standard USSR Zone 9 10 hours 10 pm IDLE International Date Line NZST New Zealand Standard NZT New Zealand 12 hours Midnight SNTP Sever IP Set the SNTP server IP address Switch Timer Display the switch current time Daylight Saving Period Set up the Daylight Saving beginning and ending time Daylight Saving beginning and ending time will be different in every year Daylight Saving Offset mins Config...

Страница 37: ...access and manage the switch through the Web browser And then click Apply button to apply the configuration NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off IP Security Interface RSTP Configuration The Rapid Spanning Tree Protocol RSTP is an evolution of the Spanning Tree Protocol and provides for faster spanning tree convergenc...

Страница 38: ...dge waits without receiving Spanning tree Protocol configuration messages before attempting a reconfiguration Enter a value between 6 through 40 Hello Time 1 10 the time that controls switch sends out the BPDU packet to check RSTP current status Enter a value between 1 through 10 Forward Delay Time 4 30 the number of seconds a port waits before changing from its Rapid Spanning Tree Protocol learni...

Страница 39: ...to exactly one other bridge i e it is served by a point to point LAN segment or can be connected to two or more bridges i e it is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administratively True is P2P enabling False is P2P disabling Admin Edge The port directly connected to end stations cannot create bridging loop in the network To conf...

Страница 40: ...ing ports When the network connection failure the backup port will automatically become a working port to recovery the failure The switch supports one Dipswitch for setting the switch as the ring master or slave mode The ring master has the rights to negotiate and place command to other switches in the X Ring group If there are 2 or more switches are in master mode then software will select the sw...

Страница 41: ...ckup port Enable Coupling Ring To enable the coupling ring function Marking the check box to enable the coupling ring function Coupling port Assign the member port Control port Set the switch as the master switch in the coupling ring Enable Dual Homing Set up one of port on the switch to be the Dual Homing port In an X Ring group maximum Dual Homing port is one Dual Homing only work when the X Rin...

Страница 42: ...ly The port priority will only follow the TOS priority that user have assigned COS first The port priority will follow the COS priority first and then other priority rule TOS first The port priority will follow the TOS priority first and the other priority rule COS priority Set the COS priority level 0 7 TOS priority The system provides 0 63 TOS priority level Each level has 4 types of priority hi...

Страница 43: ...ocol of the Internet Protocol IP suite IP manages multicast traffic by using switches routers and hosts that support IGMP Enabling IGMP allows the ports to detect IGMP queries and report packets and manage IP multicast traffic through the switch IGMP have three fundamental types of message as follows ...

Страница 44: ... can enable IGMP protocol and IGMP Query function in here User will see the IGMP snooping information in this section difference multicast group VID and member port and IP multicast addresses range from 224 0 0 0 through 239 255 255 255 IGMP Snooping interface NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off Security Manager Cha...

Страница 45: ...ation The SNMP is a Protocol that governs the transfer of information between management and agent The switch supports SNMP V1 User can define management stations as trap managers and to enter SNMP community strings User also can define a name location and contact person for the switch Fill in the system options data and then click Apply to update the changes SNMP Management interface ...

Страница 46: ...erated by the switch If no trap manager is defined no traps will issue Create a trap manager by entering the IP address of the station and a community string IP Address Key in the trap device IP Community Strings The trap device community strings And then click Add Configuration Backup In Configuration Backup user can restore the backup configuration into the industrial switch Also user can backup...

Страница 47: ...ch TFTP Server IP Address Key in the TFTP server IP Backup File Name Key in the file image name And then click Apply TFTP Backup Configuration interface TFTP Update Firmware It provides the functions to allow a user to update the switch firmware Before updating make sure user have user TFTP server ready and the firmware image is on the TFTP server TFTP Server IP Address Key in user TFTP server IP ...

Страница 48: ...ation Except the IP address subnet mask default gateway username and password will remain as user configured Click Default button to reset switch to default setting Factory Default interface System Reboot Reboot the Switch in software reset Click Reboot button to reboot the switch System Reboot interface ...

Страница 49: ...cast packet broadcast multicast packet and broadcast packet only are only for ingress packet The egress rate only supports all type packets Band Width The port1 port 8 supports port ingress and egress rate control For example assume port 1 is 10Mbps users can set it s effective egress rate as 1Mbps ingress rate is 500Kbps The switch performs the ingress rate by packet counter to meet the specified...

Страница 50: ...g events and view the system log events System Log Configuration Click Reload button to get newest system log event To clear the log events click Clear button If log event list more that one page drag down the list to switch to different page System Log Client Mode user can select in Client Only Server Only or Both mode System Log Server IP Assign the system log server IP And then click Apply butt...

Страница 51: ...duce a log message Power status When the device power status has changed the system will produce a log message SNMP Authentication Failure When the SNMP authentication fails the system will produce a log message X Ring topology change When the X Ring topology has changed the system will produce a log message Port event selection Select the per port events Per port have 3 selections Link UP Link Do...

Страница 52: ...47 After selected click Apply Event Configuration interface ...

Страница 53: ...ection does not exceed 100 meters 328 feet Diagnosing LED Indicators the Switch can be easily monitored through panel indicators to assist in identifying problems which describes common problems user may encounter and where user can find possible solutions If the power indicator does turn on when the power cord is plugged in user may have a problem with power cord Than check for loose power connec...

Страница 54: ... 1493 Bridge MIB RMON RFC 1757 RFC 2674 VLAN MIB RFC 1643 Ethernet like MIB RFC 1215 Trap MIB Private MIB for switch information X Ring port alarm TFTP firmware upgrade reset port mirror IP security management IGMP management MIB SNMP Trap Up to 3 Trap stations Cold start Port link Up Port link down Authentication Failure Private Trap for power status Port Alarm configuration Fault alarm X Ring Te...

Страница 55: ...9 125um Available distance 2KM Multi mode 30KM single mode Wavelength 1310nm multi mode single mode Back plane 1 6Gbps Packet throughput ability 1 19Mpps 64bytes Power Supply 12 48 VDC Redundant power with polarity reverse protects function and connective removable terminal block for master and slave power Power consumption 7 68 Watts X Ring 2 ports for X Ring to provide redundant backup feature a...

Страница 56: ...width control Ingress packets filter and egress packet limit The egress rate control supports all of packet type and the limit rates are 128kbps 256Kbps 512Kbps 1MB 2MB 4MB and 8MB Ingress filter packet type combination rule for Broadcast Multicast Unknown Unicast packet Broadcast Multicast packet Broadcast packet only and all of packet The ingress packet filter rate can be set follow as 1Mbps 2Mb...

Страница 57: ...000 4 2 ESD CE EN61000 4 3 RS CE EN 61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 CE EN61000 4 11 CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 Safety UL cUL CE EN60950 1 Stability testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration ...

Отзывы: