Transition Networks SISTF1011-140-LR Скачать руководство пользователя страница 8

14

SISTF10xx-140-LR(T) / -160-LR(T) / -170-LR(T)

24-hour Technical Support: 

1-800-260-1312

-- International: 

00-1-952-941-7600

Cable Specifications 

-- Continued

Copper Cable

Category 5:  

(minimum requirement)

Gauge / Attenuation:  24 to 22 AWG / 22.0 dB per 100m @ 100 MHz

• Straight-through  

OR

crossover cable may be used.

• Shielded twisted-pair (STP) 

OR

unshielded twisted-pair (UTP) may be used

• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• RJ-45 Pin-out:  Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins:

(e.g., blue/white & white/blue, orange/white & white/orange, etc.)

• Do not use flat or silver satin wire.

Crossover Cable

1
2

3
6

Straight-Through Cable

Twisted Pair #1

Twisted Pair #1

Twisted Pair #2

Twisted Pair #2

1
2

3
6

1
2

3
6

1
2

3
6

15

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

Technical Specifications

For use with Transition Networks Model Ethernet switch or equivalent

Standards:

IEEE 802.3™, 802.3u™; 802.3x™

Data Rate:

10 Mb/s, 100 Mb/s (copper); 100 Mb/s (fiber)

Processing Type:

Store and Forward
w/ IEEE802.3x™ full-duplex, non-blocking flow control

Dimensions: 

1.8" x 5.3" x 4.1" (46 mm x 135 mm x 105 mm)

Weight:

1.4 lb. (0.63 kg) (approximate)

Input Voltage:

12-48VDC, 0.2-0.7A, 2.4W (minimum), (redundant inputs)

Input Current:

0.25 A @ 24 VDC 

(SISTF10xx

-140

-LR(T))

0.35 A @ 24 VDC 

(SISTF10xx

-160

-LR(T) / 

-170

-LR(T))

Overload Current:

1.1 A 

(SISTF10xx

-140

-LR(T))

1.6 A 

(SISTF10xx

-160

-LR(T) / 

-170

-LR(T))

reverse polarity protection on all models

Forward & Filtering:

148810 pps

Packet Buffer:

256 KB

Address Table Size:

1000 Unicast MAC addresses

Latency:

< 5 

µ

s

Alarm Relay:

1.0 A @ 24 VDC

Mechanical:

Ingress Protection:  IP30

Environment:

Tmra* 

(standard temp)

: 0 to 60°C (32 to 140°F)

Tmra* 

(extended temp)

: -40 to 75°C (-40 to 167°F)

Storage Temperature:

-40 to 85°C (-40 to 185°F)

Humidity:

5 to 95%, non condensing 

Warranty:

Lifetime

*Manufacturer’s rated ambient temperature. 

The information contained in this user’s guide is subject to change.  For the most
up-to-date information see the user’s guide on line at:  www.transition.com.

CAUTION: 

This device is intended to be supplied by a listed power unit

marked LPS or Limited Power Source, provided with a connector for field
wiring terminal, and output rated 12-48VDC, 0.2-0.7 A, 24 W minimum.

CAUTION:  

This device is designed for operation with a safety extra-low

voltage (SELV) in compliance with IEC950 / EN60950 / VDE0805 and in
compliance with the low voltage directive 73/23/EEC and 93/68/EEC. 

Содержание SISTF1011-140-LR

Страница 1: ...nm multimode 2 km 1 2 miles SISTF1014 140 LR RJ 45 100 m 328 ft SC 1310 nm single mode 15 km 9 3 miles SISTF1011 140 LRT RJ 45 100 m 328 ft ST 1300 nm multimode 2 km 1 2 miles SISTF1012 140 LRT RJ 45...

Страница 2: ...The SISTF10xx 160 LR T model includes six 6 copper RJ 45 ports and two 2 duplex fiber optic ports SISTF10xx 160 LR T techsupport transition com Click the Transition Now link for a live Web chat 3 Typ...

Страница 3: ...upport transition com Click the Transition Now link for a live Web chat 5 Installation Continued CAUTION Disconnect the Ethernet switch from the DC power source BEFORE installing and or wiring the dev...

Страница 4: ...T Installation Continued Install the Port Alarm Device A user supplied port alarm device can be connected to the Ethernet switch to alert the user whenever a power fault or a port fault occurs At leas...

Страница 5: ...o devices such as PLCs or workstations AutoCross determines the characteristics of the cable connection and automatically configures the unit to link up regardless of the cable configuration Requires...

Страница 6: ...s of the corresponding fiber port 100Base FX 100M green on Fiber link is active flashing Data is being transmitted over the fiber link Copper Port LEDs The LEDs embedded in each of the RJ 45 port indi...

Страница 7: ...ON Visible and invisible laser radiation when open Do not stare into beam or view directly with optical instruments CAUTION Use of controls adjustments or the performance of procedures other than thos...

Страница 8: ...ns 1 8 x 5 3 x 4 1 46 mm x 135 mm x 105 mm Weight 1 4 lb 0 63 kg approximate Input Voltage 12 48VDC 0 2 0 7A 2 4W minimum redundant inputs Input Current 0 25 A 24 VDC SISTF10xx 140 LR T 0 35 A 24 VDC...

Страница 9: ...lation into a certain end equipment shall comply with fire enclosure request of IEC 60950 EN60950 or similar sentence techsupport transition com Click the Transition Now link for a live Web chat 17 Tr...

Страница 10: ...1012 160 LR SISTF1013 160 LR SISTF1014 160 LR SISTF1011 160 LRT SISTF1012 160 LRT SISTF1013 160 LRT SISTF1014 160 LRT SISTF1011 170 LR SISTF1012 170 LR SISTF1013 170 LR SISTF1014 170 LR SISTF1011 170...

Страница 11: ...riques d passant les limites applicables aux appareils num riques de la Class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada Europe...

Отзывы: