Installation 

-- Continued

Power the Ethernet switch

This device is suitable for use in Class I, Division 2, Groups A, B, C and D or
non-hazardous locations only. 

WARNING: EXPLOSION HAZARD

- Do not disconnect equipment

unless power has been removed or the area is known to be non-
hazardous.  

WARNING: EXPLOSION HAZARD

- Substitution of components may

impair suitability for Class I, Division 2.  

The Ethernet switch is designed for both a primary and a backup power
supply via the 6-contact terminal block, located on the top panel of the
device.  Both power inputs can be connected simultaneously to live DC
power sources.  If one power source fails, the other live source acts as a
backup, and automatically supplies the Ethernet switch with power.

CAUTION: 

Before connecting the Ethernet switch to the 12-48 VDC

power source, ensure the power source voltage is stable.

To provide PRIMARY (PWR1) power to the Ethernet switch:

1.

Insert the positive (+) DC wire from the 12-48VDC power source into the
terminal marked “V1+”.  

2.

Insert the negative (-) DC wire into the terminal marked “V1-”.  

3.

Secure the wires by tightening the corresponding screws on the side of
the terminal block.

To provide BACKUP (PWR2) power to the Ethernet switch:

1.

Insert the positive (+) DC wire from the 12-48VDC power source into the
terminal marked “V2+”.  

2.

Insert the negative (-) DC wire into the terminal marked “V2-”.  

3.

Secure the wires by tightening the corresponding screws on the side of
the terminal block.

V2-

V1-

V1+

V2+

PWR2

FAULT

PWR1

V1, V2 INPUTS

12-48 VDC

The screws to secure

the wire are located

on the side of the

terminal block.

backup power

contacts

primary power

contacts

6-contact terminal block

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

9

AutoCross 

The AutoCross feature allows either straight-through (MDI) or crossover (MDI-
X) cables to be used when connecting the Ethernet switch to devices such as
PLCs or workstations.  AutoCross determines the characteristics of the cable
connection and automatically configures the unit to link up, regardless of the
cable configuration.  (Requires no operator intervention.)

Operation

Features

Auto-Negotiation  

With the Auto-Negotiation feature, the Ethernet switch automatically
configures itself to achieve the best possible mode of operation over the
copper link.  The device broadcasts its speed (10 Mb/s or 100 Mb/s) and
duplex capabilities (either full- or half-duplex) and negotiates the best mode of
operation between the two linked devices.   

If the device is connected to a non-negotiating device over the copper link, it
will default to 10 Mb/s speed, half-duplex mode.

Plug-and-Play 

The Ethernet switch models are plug-and-play devices, so that software
configuration is not required at installation or during maintenance.

Switching, Filtering, and Forwarding 

Packets are either filtered or forwarded when they arrive at one of the
switched ports. 

Packets with source and destination addresses belonging to the same port
segment are filtered and constrained to one port (relieving the rest of the
network from the need to process them). 

Packets with a destination address to another port segment are forwarded
to the appropriate port, and are not sent to the other ports where it is not
needed. 

Packets that are used in maintaining the operation of the network (such as
the occasional multi-cast packet) are forwarded to all ports. 

The Ethernet switch operates in the store-and-forward switching mode, which
eliminates bad packets and enables peak performance to be achieved when
there is heavy traffic on the network. 

Switching and Address Learning 

The Ethernet switch address table holds up to 1K node addresses, making it
suitable for use with large networks. The address tables are self-learning, so
that as nodes are added, removed, or moved from one segment to another, the
Ethernet switch automatically keeps up with new node locations. An address-
aging algorithm deletes the least-used addresses in favor of newer, more
frequently used addresses. To reset the address buffer, power down the unit
and then power it back up.

Содержание SISTF1011-140-LR

Страница 1: ...nm multimode 2 km 1 2 miles SISTF1014 140 LR RJ 45 100 m 328 ft SC 1310 nm single mode 15 km 9 3 miles SISTF1011 140 LRT RJ 45 100 m 328 ft ST 1300 nm multimode 2 km 1 2 miles SISTF1012 140 LRT RJ 45...

Страница 2: ...The SISTF10xx 160 LR T model includes six 6 copper RJ 45 ports and two 2 duplex fiber optic ports SISTF10xx 160 LR T techsupport transition com Click the Transition Now link for a live Web chat 3 Typ...

Страница 3: ...upport transition com Click the Transition Now link for a live Web chat 5 Installation Continued CAUTION Disconnect the Ethernet switch from the DC power source BEFORE installing and or wiring the dev...

Страница 4: ...T Installation Continued Install the Port Alarm Device A user supplied port alarm device can be connected to the Ethernet switch to alert the user whenever a power fault or a port fault occurs At leas...

Страница 5: ...o devices such as PLCs or workstations AutoCross determines the characteristics of the cable connection and automatically configures the unit to link up regardless of the cable configuration Requires...

Страница 6: ...s of the corresponding fiber port 100Base FX 100M green on Fiber link is active flashing Data is being transmitted over the fiber link Copper Port LEDs The LEDs embedded in each of the RJ 45 port indi...

Страница 7: ...ON Visible and invisible laser radiation when open Do not stare into beam or view directly with optical instruments CAUTION Use of controls adjustments or the performance of procedures other than thos...

Страница 8: ...ns 1 8 x 5 3 x 4 1 46 mm x 135 mm x 105 mm Weight 1 4 lb 0 63 kg approximate Input Voltage 12 48VDC 0 2 0 7A 2 4W minimum redundant inputs Input Current 0 25 A 24 VDC SISTF10xx 140 LR T 0 35 A 24 VDC...

Страница 9: ...lation into a certain end equipment shall comply with fire enclosure request of IEC 60950 EN60950 or similar sentence techsupport transition com Click the Transition Now link for a live Web chat 17 Tr...

Страница 10: ...1012 160 LR SISTF1013 160 LR SISTF1014 160 LR SISTF1011 160 LRT SISTF1012 160 LRT SISTF1013 160 LRT SISTF1014 160 LRT SISTF1011 170 LR SISTF1012 170 LR SISTF1013 170 LR SISTF1014 170 LR SISTF1011 170...

Страница 11: ...riques d passant les limites applicables aux appareils num riques de la Class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada Europe...

Отзывы: