Transition Networks, Inc.
PCVT-48VDC-53VDC Install Guide
33568 Rev. A
Page 17 of 18
Troubleshooting
If the PCVT fails, isolate and correct the failure by determining the answers to the following questions,
and then taking the indicated action:
1.
Is the PCVT
POWER 1
LED lit?
NO
Is there a power connector plugged into the POWER 1 terminal block?
Is the VDC power source operating correctly?
Is there voltage in the range of 38-70 VDC present at the terminal block connector on the
PCVT?
Check the fuse. Contact Technical Support: US/Canada: 1-800-260-1312, International:
00-1-952-941-7600. See the
” section on page
YES
Proceed to step 2 below.
2.
Is the PCVT
POWER 2
LED lit?
NO
Is there a power connector plugged into the POWER 2 terminal block?
Is the VDC power source operating correctly?
Is there voltage in the range of 38-70 VDC present at the terminal block connector on the
PCVT?
YES
Check if the fuse is OK.
NO
The fuse is not field replaceable. Contact Technical Support: US/Canada: 1-800-260-
1312, International: 00-1-952-941-7600.
See the “
” section on page
YES
Proceed to step 3 below.
3.
Is there 53 VDC present at the terminal block connector?
NO
Check the power wiring for proper connection.
Contact Technical Support: US/Canada: 1-800-260-1312, International: 00-1-952-941-
7600.
YES
Continue operation.