background image

8

J/E-PSW-FX-02

24-Hour Technical Support: 

1-800-260-1312

-- International: 

00-1--952-941-7600

Cable Specifications

The physical characteristics must meet or exceed IEEE 802.3™ specifications. 

Fiber Cable 

Bit Error Rate:  

<10-9

single mode fiber

(recommended)

: 9 µm 

Multimode fiber 

(recommended)

:

62.5/125 µm 

Multimode fiber 

(optional)

:  

100/140, 85/140, 50/125 µm 

J/E-PSW-FX-02 (ST)

1300 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

J/E-PSW-FX-02 (SC)

1300 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

J/E-PSW-FX-02 (SM)

1310 nm single mode

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber-optic Receiver Sensitivity:

min: -31.0 dBm

max: -8.0 dBm

Link Budget:

16.0 dB

J/E-PSW-FX-02-100 (SC)*

1310TX/1550RX nm single mode

Fiber Optic Transmitter Power:

min: -13.0 dBm

max: -6.0 dBm

Fiber Optic Receiver Sensitivity:

min: -32.0 dBm

max: -3.0 dBm

Link Budget:

19.0 dB

J/E-PSW-FX-02-101 (SC)*

1550TX/1310RX nm single mode

Fiber-optic Transmitter Power:

min: -13.0 dBm

max: -6.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.0 dBm

max: -3.0 dBm

Link Budget:

19.0 dB

The fiber optic transmitters on this device meet Class I Laser safety
requirements per IEC-825/CDRH standards and comply with 21
CFR1040.10 and 21CFR1040.11.

* Single Fiber, install in pairs.

Copper Cable  

Maximum cable distance:  100 meters

Category 3: 

(

May be used for 10 Mb/s operation)

Gauge

24 to 22 AWG

Attenuation 

11.5 dB/100m @ 5-10 MHz

Category 5: 

(required for 100 Mb/s operation)

Gauge

24 to 22 AWG

Attenuation 

22.0 dB /100m @ 100 MHz

• Straight-through (MDI) or crossover (MDI-X) cable may be used.
• Shielded (STP) or unshielded (UTP) twisted-pair may be used.
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• Use only dedicated wire pairs for the active pins:

(e.g., blue/white & white/blue, orange/white & white/orange, etc.)

• Do not use flat or silver satin wire.

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

9

Cable Specifications

-- Continued

Technical Specifications

For use with Transition Networks Model J/E-PSW-FX-02 or equivalent.

Standards

IEEE 802.3™, IEEE 802.3ab™, 1998 

Data Rate:

10 Mb/s, 100 Mb/s

Dimensions

76 x 100 x 25 mm

(3 x 3.9 x 1 inches) 

Weight

181 g

(6 oz.) 

approximately 

Power Consumption:

2.5 W

Power Supply

12 VDC, 0.5 A 

(North America)

12 VDC, 0.41 A 

(Europe, Japan, Latin America)

12 VDC, 1.25 A

(N. Z., Australia, U.K., South Africa)

(The external power supply provided with this product 
is UL listed by the power supply’s manufacturer.)

Packet Size:

Memory:  48K bytes

(384 Kbits)

Unicast MAC addresses: 2 K 
Maximum packet size: 1522

(if 802.3ac tagged)

1518

(not tagged) 

bytes

MTBF 50,000 

hours

(MIL217F2 V5.0) (MIL-HDBK-217F)

125,000 hours (Bellcore7 V5.0)

Environment

Tmra*:

0 to 50°C 

(32 to 122°F )

Storage Temp:  

-20 to 85°C 

(-4 to 185°F )

Humidity

5 to 95%, non condensing 

Altitude

0 to 10,000 feet

Warranty

Lifetime

*Manufacturer’s rated ambient temperature. 

The information in this user’s guide is subject to change. For the most up-to-date
information on the J/E-PSW-FX-02 media converter, view the user’s guide on-line
at:  www.transition.com. 

Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.

CAUTION:  

Visible and invisible laser radiation when open. Do not stare into

the beam or view directly with optical instruments.

CAUTION: 

Use of controls, adjustments or the performance of procedures other

than those specified herein may result in hazardous radiation exposure.

Crossover Cable

1
2

3
6

Straight-Through Cable

Twisted Pair #1

Twisted Pair #1

Twisted Pair #2

Twisted Pair #2

1
2

3
6

1
2

3
6

1
2

3
6

Содержание J/E-PSW-FX-02(SC)

Страница 1: ...RJ 45 100 m 328 ft SC 1550 nm TX 1310 nm RX SM 20 km 12 4 miles Installation 2 Operation 5 Cable Specifications 8 Technical Specifications 9 Troubleshooting 10 Contact Us 11 Compliance Information 12...

Страница 2: ...lex 1 2 3 4 techsupport transition com Click the Transition Now link for a live Web chat 3 Installation Continued Installing the fiber cable 1 Locate IEEE 803 2 compliant 100Base FX fiber cable with m...

Страница 3: ...nsult the user s guide for the Transition Networks SPS 1872 xx DC external power supply for powering the media converter techsupport transition com Click the Transition Now link for a live Web chat 5...

Страница 4: ...r MDI X copper cables to be used when connecting to 10Base T or 100Base TX devices AutoCross determines the characteristics of the connection and automatically configures the unit to link up regardles...

Страница 5: ...isted pair may be used Pins 1 2 and 3 6 are the two active pairs in an Ethernet network Use only dedicated wire pairs for the active pins e g blue white white blue orange white white orange etc Do not...

Страница 6: ...t disconnect and reconnect the copper cable to restart the initialization process Contact Technical Support US Canada 1 800 260 1312 International 00 1 952 941 7600 techsupport transition com Click th...

Страница 7: ...bles aux appareils num riques de la class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada European Regulations Warning This is a Cla...

Отзывы: