background image

LANMaster™ T16

16-Port Ethernet™ Repeater Hub

Table of Contents

1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . 1

The LANMaster T16  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Networking the LANMaster T16  . . . . . . . . . . . . . . . . . . . . . .2
Connectors, Switch, Indicators,   . . . . . . . . . . . . . . . . . . . . . .3

2 SITE CONSIDERATIONS. . . . . . . . . . . . . . . . . . . . 4

3 INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Unpacking the LANMaster T16  . . . . . . . . . . . . . . . . . . . . . . .5
Installing LANMaster T16 at Site  . . . . . . . . . . . . . . . . . . . . . .6
Installing Network Cable  . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

10BASE-T Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
10BASE-2 Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
10BASE-5 Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
10-Mb/s Network Configuration Guidelines  . . . . . . . . . . . . . . .9
Installing Twisted-Pair 10BASE-T Cable . . . . . . . . . . . . . . . . . .11
Installing Thinnet 10BASE-2 Cable  . . . . . . . . . . . . . . . . . . . . .12
Installing Thicknet 10BASE-5 Cable  . . . . . . . . . . . . . . . . . . . .13

Powering the LANMaster T16  . . . . . . . . . . . . . . . . . . . . . . .14

4 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Monitoring Power LED  . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Monitoring Status LEDs  . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

5 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . 16

Fault Isolation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Technical Support Contact  . . . . . . . . . . . . . . . . . . . . . . . . .16

WARRANTY STATEMENT

. . . . . . . . . . . . . . . . . . . . . . . . . . . 17

ETHERNET CABLE SPECIFICATIONS

. . . . . . . . . . . . . . . . . . 19

LANMASTER T16 16-PORT HUB SPECIFICATIONS

. . . . . 21

i

19

ETHERNET CABLE SPECIFICATIONS

AUI Cable and Connector Specifications

The cable is a special 4-pair individually shielded with an overall braided
shield. 

Maximum AUI Cable Length:

50 meters (165 feet)

AUI Connector Characteristics:

AUI Port:

Male DB-15 with locking posts.

AUI Connection:

Cable shell must be grounded.  

Connector Legend:  1 Logic Ref.

6 Power Return 11 Logic Ref

2 Co

7 N/C

12 Receive

3 T

8 Logic Ref.

13 Power

4 Logic Ref.

9 Collision--

14 Logic Ref.

10 Transmit-

15 N/C

10BaseFL Cable and Connector Specifications

The physical characteristics of the 10BaseFL cable must meet or exceed IEEE
802.3 10BaseFL specifications. 

10BaseFL Cable Characteristics: 

Fiber Optic Cable Recommended:

62.5/125 µm multimode fiber

Optional:

100/140 µm multimode fiber

85/125 µm multimode fiber
50/125 µm multimode fiber

Fiber Optic Transmitter Power:

Average power: -15.0 dBm

Peak power: -12.0 dBm ±1dBm

Fiber Optic Receiver Sensitivity:

Average sensitivity: -27.4 dBm

Bit error rate:

10

-10

Maximum Cable Length:

2000 meters (6500 feet)

10BaseFL Connector Characteristics:

ST type connectors (SMA type available upon request) 

10BASE-5 Cable and Connector Specifications

The physical characteristics of the 10BASE-5 cable must meet or exceed IEEE
802.3 10BASE-5 specifications. 

10BASE-5 Cable Characteristics: 

Cable type:

RG8 Solid Coaxial (ThickNet)

Impedance: 50 

@ 10 MHz 

Capacitance:

26pF/ft

Maximum Cable Length:

500 meters (1650 feet)

Maximum number network connections:

100

Minimum distance between connections:

2.5 meters (8.2 feet)

Terminate 10BASE-5 cable at one end using a 50 ohm terminator and at the

other end using a 50 ohm terminator grounded to earth ground.

Maximum number of terminal devices on Ethernet network:

1024

Содержание E-TBT-HB-1600

Страница 1: ...ICATIONS Standards IEEE 802 3 Physical Dimensions 431 mm x 162 mm x 45 mm Input Power Universal Power Supply Input Range 90 to 265 VAC at 47 to 63 Hz AC Input TN PN Requirement Location 3344 120 volts...

Страница 2: ...sst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Telekommunikationsendeinrichtungen einschliessl...

Страница 3: ...11 Logic Ref 2 Collision 7 N C 12 Receive 3 Transmit 8 Logic Ref 13 Power 4 Logic Ref 9 Collision 14 Logic Ref 5 Receive 10 Transmit 15 N C 10BaseFL Cable and Connector Specifications The physical cha...

Страница 4: ...aggregate whether in contract tort or strict liability shall not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to...

Страница 5: ...NC TO THE EXTENT PERMITTED BY LAW TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS...

Страница 6: ...6 Failure to observe this warning could result in personal injury or death from electrical shock NOTE Failure to observe the above warning will immediately void the warranty Fault Isolation If two net...

Страница 7: ...n of valid data 2 SITE CONSIDERATIONS The site for the LANMaster T16 must provide AC power outlet for each LANMaster T16 Adequate ventilation Standard environmental conditions Isolation from electrica...

Страница 8: ...lay fuse Carefully remove fuse from fuse holder Install same size and rating replacement fuse in fuse holder Return fuse holder and fuse to installation position Snap fuse holder into place Connect po...

Страница 9: ...SE 5 Cable The LANMaster T16 provides a female AUI connector at the back for network connection to 10BASE 5 through an AUI drop cable or to 10BASE 2 10BASE T or 10BASE FL through a transceiver CONNECT...

Страница 10: ...2 cable and comes with a mating T connector and a 50 ohm segment terminator for making the cable connection To connect to 10BASE 2 network cable 1 Locate or build IEEE 802 3 compliant 10BASE 2 cable...

Страница 11: ...level more than one ground could cause false collisions that result in repeater ports partitioning and network traffic beyond the partition ceasing 10BASE 2 Requirements Thinnet 10BASE 2 cable daisy...

Страница 12: ...independent network cable connection between repeaters or between repeaters and network devices To verify the network configuration by assigning segment numbers to cable connections 1 Determine the t...

Отзывы: