10-Mb/s Baseband Network Configuration Guidelines

Ethernet 802.3 specifications define network configuration guidelines for the 10-Mb/s baseband network:

10BASE-T, 10BASE-2, and 10BASE-5 cable
segments can be installed as a single Ethernet
collision domain if the cable segments are
connected using repeaters.

When connecting LANMaster T16 repeater hubs,
the transmission path between any two Data
Terminating Equipment (DTE) network devices
can consist of no more than five segments. (A
segment is the independent network cable
connection between repeaters or between
repeaters and network devices.)

To verify the network configuration by assigning
segment numbers to cable connections:

1. Determine the two terminals in the

network which are separated by the
greatest number of segments. 

2. Assign a segment path between the

terminals by labeling the cable
connected to one of the terminals
“segment 1” and the segment connected
to the other terminal “segment n” (n =
total number of segments 

5). 

3. To verify that no segment paths contain

more than n segments, assign segment
paths and numbers to all other terminals.

4. Verify than no more than three of the

segments are 10BASE-2 or 10BASE-5
with multiple stations attached.

3

4

5

3

3

4

3

3

4

3

3

4

5

1

2

3

3

3

Содержание E-TBT-HB-1600

Страница 1: ...ICATIONS Standards IEEE 802 3 Physical Dimensions 431 mm x 162 mm x 45 mm Input Power Universal Power Supply Input Range 90 to 265 VAC at 47 to 63 Hz AC Input TN PN Requirement Location 3344 120 volts...

Страница 2: ...sst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Telekommunikationsendeinrichtungen einschliessl...

Страница 3: ...11 Logic Ref 2 Collision 7 N C 12 Receive 3 Transmit 8 Logic Ref 13 Power 4 Logic Ref 9 Collision 14 Logic Ref 5 Receive 10 Transmit 15 N C 10BaseFL Cable and Connector Specifications The physical cha...

Страница 4: ...aggregate whether in contract tort or strict liability shall not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to...

Страница 5: ...NC TO THE EXTENT PERMITTED BY LAW TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS...

Страница 6: ...6 Failure to observe this warning could result in personal injury or death from electrical shock NOTE Failure to observe the above warning will immediately void the warranty Fault Isolation If two net...

Страница 7: ...n of valid data 2 SITE CONSIDERATIONS The site for the LANMaster T16 must provide AC power outlet for each LANMaster T16 Adequate ventilation Standard environmental conditions Isolation from electrica...

Страница 8: ...lay fuse Carefully remove fuse from fuse holder Install same size and rating replacement fuse in fuse holder Return fuse holder and fuse to installation position Snap fuse holder into place Connect po...

Страница 9: ...SE 5 Cable The LANMaster T16 provides a female AUI connector at the back for network connection to 10BASE 5 through an AUI drop cable or to 10BASE 2 10BASE T or 10BASE FL through a transceiver CONNECT...

Страница 10: ...2 cable and comes with a mating T connector and a 50 ohm segment terminator for making the cable connection To connect to 10BASE 2 network cable 1 Locate or build IEEE 802 3 compliant 10BASE 2 cable...

Страница 11: ...level more than one ground could cause false collisions that result in repeater ports partitioning and network traffic beyond the partition ceasing 10BASE 2 Requirements Thinnet 10BASE 2 cable daisy...

Страница 12: ...independent network cable connection between repeaters or between repeaters and network devices To verify the network configuration by assigning segment numbers to cable connections 1 Determine the t...

Отзывы: