Model 1004

12-Port Ethernet™ Repeater Hub

20

CAUTION:  RJ connectors are NOT INTENDED FOR
CONNECTION TO THE PUBLIC TELEPHONE
NETWORK. Failure to observe this caution could result
in damage to the public telephone network.

Compliance Information
UL Listed 
C-UL Listed (Canada)
CISPR/EN55022 Class A

FCC Regulations

This equipment has been tested and found to comply with the limits for a class
A digital device, pursuant to part 15 of the FCC rules.  These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment.  This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications.  Operation of this equipment in a
residential area is likely to cause harmful interference, in which case the user
will be required to correct the interference at the user’s own expense.

Canadian Regulations

This digital apparatus does not exceed the Class A limits for radio noise for
digital apparatus set out on the radio interference regulations of the Canadian
Department of Communications.

European Regulations
Warning

This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate
measures.

Copyright Restrictions

©  1995, 1996 TRANSITION Networks Inc.
All rights reserved.  No part of this work may be reproduced or used in any
form or by any means – graphic, electronic, or mechanical – without written
permission from TRANSITION Networks Inc.

Trademark Notice

All registered trademarks and trademarks are the property of their respective
owners.

Der Anschluss dieses Gerätes an ein öffentlickes
Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die
jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie
91/263/EWG zur Angleichung der Rechtsvorschriften der
Mitgliedstaaten über Telekommunikationsendeinrichtungen
einschliesslich der gegenseitigen Anerkennung ihrer Konformität. 

10Base2 Cable Specifications

The physical characteristics of the 10Base2 cable must meet or exceed IEEE 802.3
10Base2 specifications. 

Cable Characteristics: 

Cable type:

Stranded Coaxial RG58 (ThinNet)

Impedance: 50 

@ 10 MHz 

Mutual Capacitance:

24 pF/ft ±20% @ 10 MHz

Maximum Cable Length

:

185 meters (610 feet)

Maximum number network connections:

30

Minimum distance between connections:

0.5 meters (1.6 feet)

Terminate 10Base2 cable at one end using a 50 ohm terminator and at the

other end using a 50 ohm terminator grounded to earth ground.

10BaseT Cable and Connector Specifications

The physical characteristics of the 10BaseT cable must meet or exceed IEEE 802.3
10BaseT specifications. 

10BaseT Cable Characteristics: 

Category 3 wire or better is required; category 5 wire is recommended. Either
shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO
NOT USE FLAT OR SILVER SATIN WIRE.

Category 3:

Gauge

24 to 22 AWG

Attenuation 

28 dB/1000’ @ 10 MHz

Differential Characteristic Impedance 

100 

±10% @ 10 MHz 

Category 5:

Gauge

24 to 22 AWG

Attenuation 

20 dB/1000’ @ 10 MHz

Differential Characteristic Impedance 

100 

±10% @ 10 MHz 

Maximum Cable Length:

100 meters (330 feet)

10BaseT Connector Characteristics:

The two active pairs  in a 10BaseT network are pins 1 & 2 and pins 3 & 6. Use
only dedicated wire pairs (such as blue/white & white/blue, orange/white &
white/orange) for the active pins. 10BaseT cable for unlike devices (such as
hub to terminal device) must be configured as straight through; 10BaseT cable
for like devices (such as hub to hub or terminal device to terminal device) must
be configured as crossover.

Twisted
Pair  #1

Twisted
Pair  #2

Crossover Cable

Connectors for like devices

1

2

3

6

1

2

3

6

1

2

3

6

Twisted
Pair  #1

Twisted
Pair  #2

Straight Through Cable

Connectors for unlike devices

1

2

3

6

Содержание E-TBT-HB-1004

Страница 1: ...ds IEEE 802 2 802 3 Physical Dimensions 17 0 X 7 5 X 1 7 432 mm x 191 mm x 43 mm Input Power Universal Power Supply Input Range 85 to 265 VAC at 47 to 63 Hz Rated at 40 watts maximum AC Input TN PN Requirement Location 3344 120 volts 60 hertz USA Canada Mexico 3344 100 volts 50 60 hertz Japan 3347 230 volts 50 hertz Europe 3348 240 volts 50 hertz Australia 3349 240 volts 50 hertz United Kingdom En...

Страница 2: ...en die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität 10Base2 Cable Specifications The physical characteristics of the 10Base2 cable must meet or exceed IEEE 802 3 10Base2 specifications Cable Characteristics...

Страница 3: ...th locking posts AUI Connection Cable shell must be grounded Connector Legend 1 Logic Ref 6 Power Return 11 Logic Ref 2 Collision 7 N C 12 Receive 3 Transmit 8 Logic Ref 13 Power 4 Logic Ref 9 Collision 14 Logic Ref 5 Receive 10 Transmit 15 N C 10BaseFL Cable and Connector Specifications The physical characteristics of the 10BaseFL cable must meet or exceed IEEE 802 3 10BaseFL specifications 10Bas...

Страница 4: ...the aggregate whether in contract tort or strict liability shall not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to a customer or any third party for products manufactures according to the customer s specifications C Return Procedure The customer must follow this procedure for the return of defective items 1 Lo...

Страница 5: ...IVE AND EXTENDS ONLY TO PRODUCTS ASSEMBLED BY TRANSITION NETWORKS INC TO THE EXTENT PERMITTED BY LAW TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT AND ANY WARRANTY BASED UPON PRIOR WRITTEN OR ORAL REPRESENTATIONS REGARDING SUCH PRODUC...

Страница 6: ...l shock NOTE Failure to observe the above warning will immediately void the warranty Fault Isolation If two network devices fail to communicate through the 1004 Repeater consider the following Are the LEDs described in the previous section functioning properly Do network devices have Link Integrity enabled Do network devices communicate when the 1004 Repeater is not installed between them Is flat ...

Страница 7: ...r the Model 1004 Repeater Hub must provide AC power outlet for each Model 1004 Repeater Hub Adequate ventilation Standard environmental conditions Isolation from electrical noise including radio transmitters and broadband amplifiers motors high power electrical lines or fluorescent light fixtures Additionally The twisted pair cables should not run in the same conduit with power line cables Phone l...

Страница 8: ...uring Correct Segment Number Ethernet 802 3 specifications define segment number as well as cable characteristics A segment is the cable connection between cable interfaces in an Ethernet LAN When connecting 1004 Repeaters the transmission path between any two Data Terminating Equipment DTE terminals can consist of no more than five segments To assign segment numbers to cable connections 1 Determi...

Страница 9: ...aseT cable and RJ 45 jacks for Hub to Terminal connections must be configured as straight through The 10BaseT cable and RJ 45 jacks for Hub to Hub connections must be configured as crossover NOTE When installing the 1004 Hub using the MDI port a crossover cable is not needed The MDI switch can be used to change the straight through configuration to crossover at port 1 The two active pairs in a 10B...

Страница 10: ...ge E BR SIC Redundant Fiber Optic E FL RED SIC Female AUI Connector 10Base5 or Transceiver Connection The female AUI card E AUI DT SIC provides a female AUI connecto r for connection to 10Base5 through an AUI drop cable or to 10Base2 10BaseT or10BaseFL through a transceiver NOTE The bridge card E BR SIC also provides a female AUI connector Connecting 10Base5 Using AUI Drop Cable To connect 10Base5...

Страница 11: ...talling Slide In Cards CAUTION Wear a grounding device and observe electrostatic discharge precautions when installing Slide In Cards Failure to observe this caution could result in circuit board failure NOTE Slide in Cards can be hot swapped To install a Slide In Card 1 Determine if the Slide In Cards has an SQE switch and if so verify that the SQE switch is in the OFF position NOTE SQE switches ...

Страница 12: ...odel 1004 Repeater Hub NOTE Rackmount screws and clip nuts are NOT provided with the Model 1004 Repeater Hub To install the Model 1004 Repeater Hub in 19 inch rack cabinet 1 Locate four 4 screws and clip nuts if necessary for each Model 1004 Repeater Hub to be installed 2 Carefully align the Model 1004 Repeater Hub between the 19 inch rack mounting rails at the installation position 3 Install two ...

Отзывы: