Operation
After installation, the media converter should function without
operator intervention. Use the status LEDs to monitor the media
converter operation in the network.
SDC
(Signal Detect / Coax)
On = The coax link is up.
SDF
(Signal Detect / Fiber)
On = The fiber link is up.
PWR
(Power)
On = The media converter is
connected to external power.
Remote Management
The CSDTF30xx-11x chassis media converter can remotely
manage the
SSDTF30xx-11x
, the stand-alone version of the
media converter.
For example, a local CSDTF3011-115 converter (that is
installed in a managed Transition Networks
PointSystem™
chassis) is connected, via fiber, to a remote SSDTF3011-115
converter. An example of a managed
single-fiber
network
has a local CSDTF3029-115 converter connected, via fiber,
to a remote SDTF3029-116.
See the SNMP section (below) for a list of commands that
can be used to monitor and manage the CSDTF30xx-11x
and SSDTF30xx-11x converters.
NOTE:
In a managed network, both the local and remote media converters
must be set to “software” mode (see page 2).
SNMP
See the on-line documentation that comes with Transition Networks
FocalPoint™ software for applicable commands and usage.
Use SNMP at an attached terminal or at a remote location to monitor the
media converter by monitoring:
•
Media converter power
•
Copper link and fiber link status (local and/or remote)
•
AIS detected on copper link and fiber link (local and/or remote)
•
Hardware switch settings
Also, use SNMP to enter network commands that:
•
Bootload the firmware (local only)
•
Enable/disable loopback on the copper link (local and/or remote)
•
Enable/disable loopback on the fiber link (local and/or remote)
•
Enable/disable Transmit All Ones on the fiber link when the copper
link is down (local and/or remote)
•
Enable/disable Transmit All Ones on the copper link when the fiber
link is down (local and/or remote)
•
Power-down the media converter
CSDTF30xx-11x
6
24-hour Technical Support:
1-800-260-1312
-- International:
00-1-952-941-7600
CSDTF115
FL
CL
SDC
PWR
SDF
RX
TX
Fiber
RX
TX
Coax
-- Click the
“Transition Now”
link for a live Web chat.
7
Fiber Cable
Single mode fiber (recommended): 9 µm
Multimode fiber (recommended):
62.5/125 µm
Multimode fiber (optional):
100/140, 85/140, 50/125 µm
CSDTF3011-115
850 nm multimode
Fiber Optic Transmitter Power:
min: -14.0 dBm
max: -12.0 dBm
Fiber Optic Receiver Sensitivity:
min: -25.0 dBm
max: -12.0 dBm
Link Budget:
11.0 dB
CSDTF3012-115
1310 nm single mode
Fiber-optic Transmitter Power:
min: -27.0 dBm
max: -10.0 dBm
Fiber-optic Receiver Sensitivity:
min: -37.0 dBm
max: -14.0 dBm
Link Budget:
10.0 dB
CSDTF3013-115
850 nm multimode
Fiber Optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber Optic Receiver Sensitivity:
min: -32.5 dBm
max: -14.0 dBm
Link Budget:
13.5 dB
CSDTF3014-115
1310 nm single mode
Fiber-optic Transmitter Power:
min: -15.0 dBm
max: -8.0 dBm
Fiber-optic Receiver Sensitivity:
min: -31.0 dBm
max: -8.0 dBm
Link Budget:
16.0 dB
CSDTF3015-115
1310 nm single mode
Fiber Optic Transmitter Power:
min: -8.0 dBm
max: -2.0 dBm
Fiber Optic Receiver Sensitivity:
min: -38.0 dBm
max: -8.0 dBm
Link Budget:
30.0 dB
CSDTF3016-115
1310 nm single mode
Fiber-optic Transmitter Power:
min: -5.0 dBm
max: 0.0 dBm
Fiber-optic Receiver Sensitivity:
min: -38.0 dBm
max: -8.0 dBm
Link Budget:
33.0 dB
CSDTF3017-115
1550 nm single mode
Fiber-optic Transmitter Power:
min: -5.0 dBm
max: 0.0 dBm
Fiber-optic Receiver Sensitivity:
min: -34.0 dBm
max: -7.0 dBm
Link Budget:
29.0 dB
CSDTF3018-115
1300 nm multimode
Fiber-optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber-optic Receiver Sensitivity:
min: -33.5 dBm
max: -14.0 dBm
Link Budget:
14.5 dB
Cable Specifications
Copper Cable
E1:
Cable Type:
RG-59
Gauge:
24 to 22 AWG
Differential Characteristic Impedance: 75 ohm +/- 10%