Transition Networks CSDTF30xx-11x Скачать руководство пользователя страница 4

Operation 

After installation, the media converter should function without
operator intervention.  Use the status LEDs to monitor the media
converter operation in the network.  

SDC

(Signal Detect / Coax)

On = The coax link is up.

SDF

(Signal Detect / Fiber)

On = The fiber link is up.

PWR

(Power)

On = The media converter is

connected to external power.

Remote Management 

The CSDTF30xx-11x chassis media converter can remotely
manage the 

SSDTF30xx-11x

, the stand-alone version of the

media converter.  

For example, a local CSDTF3011-115 converter (that is
installed in a managed Transition Networks 

PointSystem™

chassis) is connected, via fiber, to a remote SSDTF3011-115
converter.  An example of a managed 

single-fiber

network

has a local CSDTF3029-115 converter connected, via fiber,
to a remote SDTF3029-116.

See the SNMP section (below) for a list of commands that
can be used to monitor and manage the CSDTF30xx-11x
and SSDTF30xx-11x converters.

NOTE: 

In a managed network, both the local and remote media converters

must be set to “software” mode (see page 2). 

SNMP

See the on-line documentation that comes with Transition Networks
FocalPoint™ software for applicable commands and usage.

Use SNMP at an attached terminal or at a remote location to monitor the
media converter by monitoring:

Media converter power

Copper link and fiber link status (local and/or remote)

AIS detected on copper link and fiber link (local and/or remote)

Hardware switch settings

Also, use SNMP to enter network commands that:

Bootload the firmware (local only)

Enable/disable loopback on the copper link (local and/or remote)

Enable/disable loopback on the fiber link (local and/or remote)

Enable/disable Transmit All Ones on the fiber link when the copper
link is down (local and/or remote)

Enable/disable Transmit All Ones on the copper link when the fiber
link is down (local and/or remote)

Power-down the media converter

CSDTF30xx-11x

6

24-hour Technical Support: 

1-800-260-1312

-- International: 

00-1-952-941-7600

CSDTF115

FL

CL

SDC

PWR

SDF

RX

TX

Fiber

RX

TX

Coax

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

7

Fiber Cable 

Single mode fiber (recommended):   9 µm 
Multimode fiber (recommended):  

62.5/125 µm 

Multimode fiber (optional):  

100/140, 85/140, 50/125 µm 

CSDTF3011-115

850 nm multimode

Fiber Optic Transmitter Power:

min: -14.0 dBm

max: -12.0 dBm

Fiber Optic Receiver Sensitivity:

min: -25.0 dBm

max: -12.0 dBm

Link Budget:

11.0 dB

CSDTF3012-115

1310 nm single mode

Fiber-optic Transmitter Power:

min: -27.0 dBm

max: -10.0 dBm

Fiber-optic Receiver Sensitivity:

min: -37.0 dBm

max: -14.0 dBm

Link Budget:

10.0 dB

CSDTF3013-115

850 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -32.5 dBm

max: -14.0 dBm

Link Budget:

13.5 dB

CSDTF3014-115

1310 nm single mode

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber-optic Receiver Sensitivity:

min: -31.0 dBm

max: -8.0 dBm

Link Budget:

16.0 dB

CSDTF3015-115

1310 nm single mode

Fiber Optic Transmitter Power:

min: -8.0 dBm

max: -2.0 dBm

Fiber Optic Receiver Sensitivity:

min: -38.0 dBm

max: -8.0 dBm

Link Budget:

30.0 dB

CSDTF3016-115

1310 nm single mode

Fiber-optic Transmitter Power:

min: -5.0 dBm

max: 0.0 dBm

Fiber-optic Receiver Sensitivity:

min: -38.0 dBm

max: -8.0 dBm

Link Budget:

33.0 dB

CSDTF3017-115

1550 nm single mode

Fiber-optic Transmitter Power:

min: -5.0 dBm

max: 0.0 dBm

Fiber-optic Receiver Sensitivity:

min: -34.0 dBm

max: -7.0 dBm

Link Budget:

29.0 dB

CSDTF3018-115

1300 nm multimode

Fiber-optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber-optic Receiver Sensitivity:

min: -33.5 dBm

max: -14.0 dBm

Link Budget:

14.5 dB

Cable Specifications

Copper Cable 

E1:

Cable Type:

RG-59

Gauge:

24 to 22 AWG

Differential Characteristic Impedance: 75 ohm +/- 10%

Содержание CSDTF30xx-11x

Страница 1: ...gle mode 60 km 37 3 miles CSDTF3017 115 75 ohm BNC coax 100 m 328 ft SC 1550 nm single mode 80 km 49 7 miles CSDTF3018 115 75 ohm BNC coax 100 m 328 ft MT RJ 1300 nm multimode 2 km 1 2 miles CSDTF3022...

Страница 2: ...ter mode is determined by the most recently saved on board microprocessor settings Software Mode Hardware Mode H S H S E1 Configuration switch 4 IMPORTANT Switch 4 MUST be set to the down position to...

Страница 3: ...E D 0 50 LA PWR RXF RXC LNK COL LKS PWR LKM 10BASE 2 10BASE FL LKS PWR LKM LKS PWR LKM Multimode Singlemode TX RX TX RX Multimode Singlemode TX RX TX RX Multimode Singlemode TX RX TX RX I 0 TERM INIT...

Страница 4: ...le Transmit All Ones on the copper link when the fiber link is down local and or remote Power down the media converter CSDTF30xx 11x 6 24 hour Technical Support 1 800 260 1312 International 00 1 952 9...

Страница 5: ...ein may result in hazardous radiation exposure techsupport transition com Click the Transition Now link for a live Web chat 9 Technical Specifications For use with Transition Networks Model CSDTF30xx...

Страница 6: ...Device Fiber Copper Copper Local Converter w SNMP Management Remote Converter Bit Error Test Equipment Remote Device Fiber Copper Copper Local Converter w SNMP Management Remote Converter Bit Error Te...

Страница 7: ...Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class A prescrites dans le R g...

Отзывы: