CPSMP-130 & CPSMP-140

2

24-hour Technical Support: 

1-800-260-1312

-- International: 

00-1-952-941-7600

READ AND FOLLOW ALL WARNING NOTICES & INSTRUCTIONS MARKED ON
THE PRODUCT OR INCLUDED IN THE MANUAL.

CAUTION:  All installation and service must be performed by qualified service
personnel.

CAUTION:  Wear a grounding device and observe electrostatic discharge
precautions when installing or servicing the power supply module.  Failure to
observe this caution could result in damage to, and subsequent failure of, the
power supply module.

The Power Supply Module in the 13-Slot Chassis

CPSMP-130 Power Supply (48-VDC)

The CPSMP-130 power supply module may replace an existing 48-VDC power
supply or be installed in the second installation slot (see drawing below) of the

PointSystem™ 

13-slot chassis to become the optional, redundant power

supply.

CPSMP-140 Power Supply (24-Volt)

The CPSMP-140 power supply module may replace an existing 24-VDC power
supply or be installed in the second installation slot (see drawing above) of the

PointSystem™ 

13-slot chassis to become the optional, redundant power

supply.

NOTE:

Both the CPSMP-130 and the CPSMP-140 DC power supply modules

may be installed as the redundant power supply in 

any

of the three

PointSystem™ 

13-slot chassis:

CPSMC1300-100 (AC chassis)

CPSMC1310-100 (48-VDC chassis)

CPSMC1320-100 (24-VDC chassis)

For more information, see the user’s guide for the CPSMC13xx-100 13-slot
chassis on-line at:  www.transition.com.

I
0

-
+

DC Power

Supply

Second

Installation Slot

3

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

WARNING:  Do NOT connect the power supply module to the external power
source before installing it into the chassis.  Failure to observe this caution could
result in equipment damage and/or personal injury or death.

Install the Power Supply Module

CAUTION: Ensure that the power supply module has been disconnected
from the external power source and the module’s On/Off switch has been
set to “0”.  Failure to observe this caution could result in damage to, and
subsequent failure of, the power supply module.

NOTE:

The power supply module may be “hot swapped” (i.e., installed in the

chassis while the chassis is in operation) 

provided the module to be installed

has been disconnected from its external power source and the module’s
On/Off switch has been set to “0”.

To install the power supply module into the 

PointSystem™

chassis:

1.

Loosen the screw that secures the protective plate to the chassis and pull
the plate away from the chassis.

2.

Set the On/Off switch on the power supply module to 

“0”

.

3.

Carefully slide the power supply module into the installation slot,
aligning the module with the installation guides.  

4.

Ensure that the power supply module is firmly seated inside the chassis.

5.

Rotate the attached panel fastener screw clockwise to secure the power
supply module to the chassis.

I

0

-
+

I

0

-
+

I

0

-
+

Содержание CPSMP-130

Страница 1: ...switch that when set to I allows the power supply module to supply power to the chassis and any installed modules A panel fastener screw that secures the power supply module to the chassis A power LED indicator A handle for installing and removing the power supply module to from the chassis A fuse installed on the circuit board inside the power supply module s housing A set of three 3 external pow...

Страница 2: ...sis For more information see the user s guide for the CPSMC13xx 100 13 slot chassis on line at www transition com I 0 DC Power Supply Second Installation Slot 3 techsupport transition com Click the Transition Now link for a live Web chat WARNING Do NOT connect the power supply module to the external power source before installing it into the chassis Failure to observe this caution could result in ...

Страница 3: ...ure safe operation and to comply with customer installation requirements and local electrical codes Prior to installation use a voltmeter ohmmeter to check the wiring for the presence of earth ground A readily accessible disconnect device as part of the building installation shall be incorporated into the fixed wiring The disconnect device a 24 VDC 15 or 20A circuit breaker or switch must be inclu...

Страница 4: ... power supply module to 0 2 Verify that the external power source is NOT powered 3 Disconnect the positive terminal from the external power connector marked 4 Disconnect the negative terminal from the external power connector marked 5 Disconnect the ground terminal from the external power connector marked chassis ground 6 Rotate the attached panel fastener screw counter clockwise 7 Carefully slide...

Страница 5: ...odule out of the chassis I 0 I 0 GND Power LED External Power Connectors On Off Switch Panel Fastener Screw I 0 I 0 9 techsupport transition com Click the Transition Now link for a live Web chat WARNING Do NOT connect the power supply module to the external power source before installing it into the chassis Failure to observe this caution could result in equipment damage and or personal injury or ...

Страница 6: ...hnical support is available 24 hours a day US and Canada 1 800 260 1312 International 00 1 952 941 7600 Transition Now Chat live via the Web with Transition Networks Technical Support Log onto www transition com and click the Transition Now link Web Based Seminars Transition Networks provides seminars via live web based training Log onto www transition com and click the Learning Center link E Mail...

Страница 7: ...nadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada European Regulations Warning This is a Class A product In a domestic environment this product may cause rad...

Отзывы: