background image

28

CPSMC08xx-100  PointSystem

Chassis

Contact Us

Technical Support

Technical support is available 24 hours a day.

United States:

1-800-260-1312

International:

00-1-952-941-7600

Transition Now

Chat live via the Web with a Transition Networks Technical Support Specialist.

Log onto 

www.transition.com

and click the 

Transition Now

link.

Web-Based Seminars

Transition Networks provides 12-16 seminars per month via live web-based training.

Log onto 

www.transition.com

and click the 

Learning Center

link.

E-Mail

Ask a question anytime by sending an e-mail message to our technical support staff.

[email protected]

Address

Transition Networks

6475 City West Parkway
Minneapolis, MN  55344, USA

telephone:  952-941-7600
toll free:

800-526-9267

fax:            952-941-2322

Содержание CPSMC0800-100

Страница 1: ...Transition Networks CPSMC08xx 100 8 Slot PointSystem Chassis User s Guide revision B CPSMC0800 100 AC powered CPSMC0810 100 DC powered...

Страница 2: ...arning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Achtung Dieses ist ein Ger t der F...

Страница 3: ...les 11 3 Powering the CPSMC08xx 100 12 3 1 Primary Power Supply 12 3 1 1 AC Power Supply 12 3 1 2 DC Power Supply 13 3 2 Auxiliary Power Supply 14 3 2 1 AC Auxiliary Power Supply 14 3 2 2 DC Auxiliary...

Страница 4: ...e fans help remove heat from the chassis With installed PointSystem management module s P N CPSMM 120 200 or 210 the CPSMC08xx 100 can be managed and monitored via An SNMP application such as Transiti...

Страница 5: ...ser s Guide 33270 The following items are optional accessories for the CPSMC08xx 100 8 slot PointSystem chassis Item Part Number External AC Power Supply CPSMP 180 optional External DC Power Supply CP...

Страница 6: ...the face place with the enclosed bolt 2 1 2 Calculating the Power Consumption CAUTION Before installing the media converter slide in modules refer to the power consumption data for each individual me...

Страница 7: ...slots 2 Align the slide in module with the chassis installation slot so that the panel fastener screw is at the left of the slide in module 3 Carefully slide the slide in module into the installation...

Страница 8: ...from the chassis 2 Align the replacement slide in module with the chassis installation slot so that the panel fastener screw is to the left 3 Carefully slide the replacement slide in module into the...

Страница 9: ...Slot Master Management Module CPSMM 200 Dual Slot Master Management Module The optional CPSMM 200 Dual Slot Master Management Module can also be installed in the CPSMC08xx 100 chassis to enable netwo...

Страница 10: ...PSMM 120 Single Slot Master Management Module OR CPSMM 210 Single Slot Expansion Management Module If chassis face plates are covering the installation slots remove one 1 management module protective...

Страница 11: ...e management module to be replaced by loosening the panel fastener screw that secures the module to the chassis front Slide the module from the chassis 2 Align the replacement module with the installa...

Страница 12: ...internal AC power supply which is accessed through a power inlet on the front panel The power cord is included To power the CPSMM0800 100 chassis through the primary AC power supply 1 Connect the fem...

Страница 13: ...e manual CAUTION All installation and service must be performed by qualified service personnel The CPSMC0810 100 includes an internal DC power supply which is accessed through the power terminal block...

Страница 14: ...CPSMP 190 as the Auxiliary power supply Likewise the CPSMC0810 100 with the internal DC power supply can have either the AC powered CPSMP 180 or the DC powered CPSMP 190 as the Auxiliary power supply...

Страница 15: ...ed on the product or included in the manual CAUTION All installation and service must be performed by qualified service personnel To power the CPSMC08xx 100 chassis through the DC auxiliary power supp...

Страница 16: ...40 C If the chassis is installed in a closed or multi unit rack assembly the operating ambient temperature of the the rack environment may be greater than room ambient NOTE Rack mounted equipment mus...

Страница 17: ...ews through the mounting bracket into the installation holes on side of the chassis 5 Repeat steps 3 and 4 for the second mounting bracket 6 Locate four 4 screws not provided and optional clip nuts no...

Страница 18: ...red torque to the fasteners is specified by the connector s manufacturer To properly ground the CPSMC08xx 100 chassis 1 Obtain one 1 properly terminated grounding conductor 12 AWG copper wire gauge or...

Страница 19: ...is Mpls MN 55344 Mpls MN 55344 Input Power Input Power 110 240 VAC 110 240 VAC 1 6A max 60W max 1 6A max 60W max 50 60 Hz 50 60 Hz CPSMC 0800 8 Slot Chassis Mpls MN 55344 Mpls MN 55344 Input Power Inp...

Страница 20: ...or at one end of the cascade cable into the management module s RJ 45 port labeled OUT 3 At the next chassis in the series Plug the RJ 45 connector at the other end of the cascade cable into the manag...

Страница 21: ...dicators to help monitor the network Refer to the user s guide included with each management module and slide in module to interpret the LED indicators on the modules 10BASE T INPORT MCCM10 MGMT MASTE...

Страница 22: ...o configure and manage the CPSMC08xx 100 chassis from an attached terminal or from a remote networked computer The firmware includes the Transition Networks Command Line Interface CLI a telnet server...

Страница 23: ...remote NMS both the RJ 45 Ethernet port and the NMS must be connected to a network with Internet access RX TX LNK PWR RESET DB 9 CFETF110 SPD PWR FRX CRX FLNK CLNK 10 100TX RX TX 10 100SX LKS PWR LKM...

Страница 24: ...D is NOT illuminated Ensure the management module is firmly seated in the slot Press the RESET button on the management module Contact Tech Support 1 800 260 1312 Int l 00 1 952 941 7600 4 For the rem...

Страница 25: ...certified by the manufacturer to comply with DHHS Rule 21 CFR Subchapter J applicable at the date of manufacture The fiber optic transmitters on this device meets Class I Laser safety requirements per...

Страница 26: ...ect CD 1 Receive Data RXD 2 Transmit Data TXD 3 Data Terminal Ready DTR 4 Signal Ground GND 5 Data Set Ready DSR 6 Request To Send RTS 7 Clear To Send CTS 8 RJ 45 Cable Category 5 Gauge 24 to 22 AWG A...

Страница 27: ...equirements of the media and port type For example Shielded RJ 45 cable used for 100Base Tx Ethernet MUST be grounded at both cable endpoints via shielded RJ 45 jacks Shielded RS 232 cable MUST have t...

Страница 28: ...www transition com and click the Transition Now link Web Based Seminars Transition Networks provides 12 16 seminars per month via live web based training Log onto www transition com and click the Lea...

Страница 29: ...uct To return a defective product for warranty coverage contact Transition Networks technical support department for a return authorization number Transition s technical support department can be reac...

Страница 30: ...by Transition Networks for a fee will carry a 180 day limited warranty All warranty claims are subject to the restrictions and conventions set forth by this document Transition Networks reserves the...

Отзывы: