Transition Networks CGETF10XX-10X Скачать руководство пользователя страница 4

CGETF10xx-10x

24-hour Technical Support: 1-800-260-1312   International: 00-1-952-941-7600    

Operation - Continued

Link Pass-Through

The Link Pass-Through feature allows the media converter to monitor both the
fiber and copper RX (receive) ports for loss of signal.  In the event of a loss of
an RX signal (1), the media converter will automatically disable the TX
(transmit) signal (2), thus, “passing through” the link loss (3).  The far-end
device is automatically notified of the link loss (4), which prevents the loss of
valuable data unknowingly transmitted over an invalid link. 

Full-Duplex network

In a full-duplex network, maximum cable lengths are determined by the type
of cables that are used.  See pages 1 and 2 for the cable specifications for the
different CGETF10xx-10x models.  

The 512-Bit Rule does not apply in a full-duplex network.

Half-Duplex network 

(512-Bit Rule)

In a half-duplex network, the maximum cable lengths are determined by the
round trip delay limitations of each Fast Ethernet collision domain.  

(A

collision domain is the longest path between any two terminal devices, e.g.  a
terminal, switch or router.) 

The 512-Bit Rule determines the maximum length of cable permitted by
calculating the round-trip delay in bit-times (BT) of a particular collision
domain.  If the result is less than or equal to 512 BT, the path is good.  

For more information on the 512-Bit Rule, see the white paper titled
“Collision Domains” on the Transition Networks website at:
www.transition.com

4

1

Media

Converter A

Media

Converter B

Near-End

Device

Far-End

Device

original fault

on the copper link

media converter B

disables the copper link

media converter A

disables the fiber TX link

3

2

media converter B

loses the fiber RX link

[email protected] -- Click the “Transition Now” link for a live Web chat.

7

SNMP

Use SNMP at an attached terminal or at a remote location to monitor the
media converter by monitoring:

Copper and fiber link/receive status

Hardware switch settings

Receive error count

Also, use SNMP to enter network commands that:

Enable/disable full-duplex and half-duplex advertisement

Enable/disable Link Pass-Through

Enable/disable Auto-Negotiation

Symmetric pause

Asymmetric TX 

(transmit)

pause

Asymmetric RX 

(receive) 

pause

Disable pause

See the on-line documentation that comes with Transition Networks
FocalPoint™ software for applicable commands and usage.  

Operation 

Pause 

The pause feature can improve network performance by allowing one end of
the link to signal the other to discontinue frame transmission for a set period
of time to relieve buffer congestion.

In Hardware mode, the pause feature can be set to

Disable 

(i.e., no pause)

Enable 

(i.e., symmetrical pause)

In Software mode, the pause feature can be set to one of four settings:

Disable 

(i.e., no pause)

Symmetrical pause

Asymmetric TX (

transmit)

pause

Asymmetric RX 

(receive)

pause

Enable the pause feature if it is present on ALL network devices attached to
the media converter(s).  Otherwise, disable the pause feature.

Содержание CGETF10XX-10X

Страница 1: ...single mode 10 km 6 2 miles CGETF1015 105 RJ 45 1000Base T 100 m 328 ft SC 1000Base LX 1310 nm single mode 25 km 15 5 miles CGETF1017 105 RJ 45 1000Base T 100 m 328 ft SC 1000Base LX 1550 nm single m...

Страница 2: ...Installation Continued Set the 4 position switch The 4 position switch is located on the side of the media converter Use a small flat blade screwdriver to set the recessed switches 1 Twisted Pair Ful...

Страница 3: ...FETF110 CFMFF100 LA PWR RXF RXC LNK COL SPD PWR FRX CRX FLNK CLNK 100BASE TX RX TX 100BASE FX Link Alert E D 0 50 LA PWR RXF RXC LNK COL LKS PWR LKM 10BASE 2 10BASE FL 10BASE T LKS PWR LKM Multimode S...

Страница 4: ...titled Collision Domains on the Transition Networks website at www transition com 4 1 Media Converter A Media Converter B Near End Device Far End Device original fault on the copper link media conver...

Страница 5: ...00 1 952 941 7600 9 techsupport transition com Click the Transition Now link for a live Web chat Cable Specifications Continued Fiber Cable Continued CGETF1039 105 850 nm multimode Fiber Optic Transmi...

Страница 6: ...1000Base SX LX port continue below If there is activity on the 1000Base SX LX port disconnect and reconnect the fiber cable to restart the initialization process Restart the workstation to restart th...

Страница 7: ...Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Achtung Dieses ist ein Ger t der...

Отзывы: