![Transition Networks CFMFF1313-200 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/transition-networks/cfmff1313-200/cfmff1313-200_user-manual_1151683004.webp)
6
CFMFFxxxx-2xx
24-hour Technical Support: 1-800-260-1312 – International: 00-1-952-941-7600
Operation
Status LEDs
Use the three status LEDs on the media converter
(shown here)
to monitor its
operation in the network.
PWR
ON = Connection to external power.
LKS
ON = Singlemode fiber link is up.
LKM
ON = Multimode fiber link is up.
SNMP
Use SNMP at an attached terminal or at a remote location to monitor the media
converter by monitoring:
•
Media converter power
•
Singlemode fiber link status
•
Multimode fiber link status
Also, use SNMP to enter network commands that:
•
Power down the media converter
•
Disable the multimode transmitter
•
Disable the singlemode transmitter
See the on-line documentation that comes with Transition Networks
FocalPoint™
software for applicable commands and usage at
www.transition.com.
Link Pass-Through
The Link Pass-Through feature allows the media converter to monitor RX
(receive)
ports for loss of signal. In the event of a loss of an RX signal on one
media port, the media converter will automatically disable the TX
(transmit)
signal of the other media port, thus “passing through” the link loss.
7
[email protected] – Click the “Transition Now” link for a live Web chat.
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Singlemode fiber
(recommended):
9 µm
Multimode fiber
(recommended):
62.5/125 µm
Multimode fiber
(optional)
:
100/140, 85/140, 50/125 µm
155 Mb/s fiber specifications
(CFMFF13xx-20x)
Bit Error Rate:
<10-9
Port 1:
1300 nm multimode duplex
Fiber Optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber Optic Receiver Sensitivity:
min: -30.0 dBm
max: -14.0 dBm
Link Budget:
11.0 dB
Port 2:
CFMFF1313-200
1300 nm multimode duplex
Fiber Optic Transmitter Power:
min: -19.0 dBm
max: -14.0 dBm
Fiber Optic Receiver Sensitivity:
min: -30.0 dBm
max: -14.0 dBm
Link Budget:
11.0 dB
CFMFF1314-200
1310 nm singlemode
Fiber-optic Transmitter Power:
min: -15.0 dBm
max: -8.0 dBm
Fiber-optic Receiver Sensitivity:
min: -31.0 dBm
max: -8.0 dBm
Link Budget:
16.0 dB
CFMFF1315-200
1310 nm singlemode
Fiber-optic Transmitter Power:
min: -8.0 dBm
max: -2.0 dBm
Fiber-optic Receiver Sensitivity:
min: -34.0 dBm
max: -7.0 dBm
Link Budget:
26.0 dB
CFMFF1316-200
1310 nm singlemode
Fiber-optic Transmitter Power:
min: -5.0 dBm
max: 0.0 dBm
Fiber-optic Receiver Sensitivity:
min: -34.0 dBm
max: -7.0 dBm
Link Budget:
29.0 dB
CFMFF1317-200
1550 nm singlemode
Fiber-optic Transmitter Power:
min: -5.0 dBm
max: 0.0 dBm
Fiber-optic Receiver Sensitivity:
min: -34.0 dBm
max: -7.0 dBm
Link Budget:
29.0 dB
CFMFF1329-200
1310 nm (TX) / 1550 nm (RX) singlemode
Fiber-optic Transmitter Power:
min: -13.0 dBm
max: -6.0 dBm
Fiber-optic Receiver Sensitivity:
min: -32.0 dBm
max: -3.0 dBm
Link Budget:
19.0 dB
CFMFF1329-201
1550 nm (TX) / 1310 nm (RX) singlemode
Fiber-optic Transmitter Power:
min: -13.0 dBm
max: -6.0 dBm
Fiber-optic Receiver Sensitivity:
min: -32.0 dBm
max: -3.0 dBm
Link Budget:
19.0 dB
CFMFF1329-202
1310 nm (TX) / 1550 nm (RX) singlemode
Fiber-optic Transmitter Power:
min: -8.0 dBm
max: -3.0 dBm
Fiber-optic Receiver Sensitivity:
min: -33.0 dBm
max: -3.0 dBm
Link Budget:
25.0 dB
CFMFF1329-203
1550 nm (TX) / 1310 nm (RX) singlemode
Fiber-optic Transmitter Power:
min: -8.0 dBm
max: -3.0 dBm
Fiber-optic Receiver Sensitivity:
min: -33.0 dBm
max: -3.0 dBm
Link Budget:
25.0 dB