Compliance Information

CISPR22/EN55022 Class A & B + EN55024
CE Mark

FCC Regulations

This equipment has been tested and found to comply with the limits for a Class A & B digital
device, pursuant to part 15 of the FCC rules.  These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment.  This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications.  Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be required to correct the
interference at the user's own expense.

Canadian Regulations

This digital apparatus does not exceed the Class A & B limits for radio noise for digital
apparatus set out on the radio interference regulations of the Canadian Department of
Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la Class A & B prescrites dans le Règlement sur le
brouillage radioélectrique édicté par le ministère des Communications du Canada.

CAUTION:   RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK.   Failure to observe this caution could result in
damage to the public telephone network.

Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer
Konformität.  

In accordance with European Union Directive 2002/96/EC of the European
Parliament and of the Council of 27 January 2003, Transition Networks will accept
post usage returns of this product for proper disposal. The contact information for
this activity can be found in the 'Contact Us' portion of this document. 

*

Typical maximum cable distance.  Actual distance is dependent on the physical
characteristics of the network.  (TX) = transmit  (RX) = receive

CFETF1017-353 

RJ-45
100 m 

(328 ft)*

SC, 1530 nm single mode, CWDM 
80km

(49.7.miles)*

CFETF1017-351 

RJ-45
100 m 

(328 ft)*

SC, 1510 nm single mode, CWDM 
80km 

(49.7.miles)*

CFETF1017-355 

RJ-45
100 m 

(328 ft)*

SC, 1550 nm single mode, CWDM
80km 

(49.7.miles)*

CFETF1017-357

RJ-45
100 m 

(328 ft)*

SC, 1570 nm single mode, CWDM 
80km 

(49.7.miles)*

Part Number

Port One - Copper
100Base-TX

Port Two - Duplex Fiber-Optic
100Base-FX

Содержание CFETF1011-205

Страница 1: ...5 RJ 45 100 m 328 ft SC 1310 nm single mode 20 km 12 4 miles CFETF1015 205 RJ 45 100 m 328 ft SC 1310 nm single mode 40 km 24 9 miles CFETF1016 205 RJ 45 100 m 328 ft SC 1310 nm single mode 60 km 32 3 miles CFETF1017 205 RJ 45 100 m 328 ft SC 1550 nm single mode 80 km 49 7 miles CFETF1018 205 RJ 45 100 m 328 ft MT RJ 1300 nm multimode 2 km 1 2 miles CFETF1019 205 RJ 45 100 m 328 ft LC 1310 nm sing...

Страница 2: ...prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK Failure to observe this caution could result in damage to the public telephone network Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG Mitgliedstaaten verstösst geg...

Страница 3: ... Software Software controls the function of the board The DIP switches do not function in software mode Hardware Mode Software Mode H H S S Link Pass Through up enabled Pause up enabled Auto Negotiation up enabled Far End Fault up enabled 1 2 3 4 Contact Us Technical Support Technical support is available 24 hours a day US and Canada 1 800 260 1312 International 00 1 952 941 7600 Transition Now Ch...

Страница 4: ...ate and correct the failure by determining the answers to the following questions and then taking the indicated action 1 Is the PWR LED on the media converter illuminated NO Is the media converter installed properly in the chassis Is the power cord properly installed in the chassis and at the external power source Does the external power source provide power Contact Technical Support 1 800 260 131...

Страница 5: ...hown RX TX RX TX RJ 45 Port Media Converter RJ 45 Port On other device workstation switch etc Point System Chassis Technical Specifications For use with Transition Networks Model CFETF10xx 205 or equivalent Standards IEEE 802 3 Data Rate 100 Mb s Dimensions 3 4 x 5 0 x 0 87 86 x 185 x 22 mm Weight 3 oz 91 g approximate Power Consumption 3 5 watts 200 mA 13 9 VDC MTBF 382 956 hours MIL217F2 V5 0 MI...

Страница 6: ...twork the maximum cable lengths are determined by the round trip delay limitations of each Fast Ethernet collision domain A collision domain is the longest path between any two terminal devices e g a terminal switch or router The 512 Bit Rule determines the maximum length of cable permitted by calculating the round trip delay in bit times BTU of a particular collision domain If the result is less ...

Страница 7: ...ia converter B disables the copper link media converter A disables the copper link 3 4 2 1 4 1 Media Converter A Media Converter B Near End Device Far End Device original fault on the copper link media converter B disables the copper link media converter A disables the fiber TX link 3 2 media converter B loses the fiber RX link Cable Specifications The physical characteristics must meet or exceed ...

Страница 8: ...ite blue orange white white orange etc Do not use flat or silver satin wire Straight Through Cable Crossover Cable Twisted Pair 1 Twisted Pair 2 Twisted Pair 2 Twisted Pair 1 Operation Continued SUMP See the on line documentation that comes with Transition Networks FocalPoint software for applicable commands and usage Use SUMP at an attached terminal or at a remote location to monitor the followin...

Отзывы: