![Transition Networks CAPTF3311-100 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/transition-networks/captf3311-100/captf3311-100_user-manual_1151567007.webp)
12
CAPTF33xx-1xx
24-hour Technical Support:
1-800-260-1312
-- International:
00-1-952-941-7600
RJ-11C Connector Specification
Unit A (Telephone Emulation)
Connector:
RJ-11C
Impedance:
600
Ω
REN:
0.4 B
Loop Current:
10 to 100 mA
Insertion Loss:
0.0 ± 1.0 dB at 1000 Hz
(When both ports are terminated at 600
Ω
.)
Unit B (Central Office Emulation)
Connector:
RJ-11C
Impedance:
600
Ω
Battery Source:
48 VDC +/- 5V
Ringing Supply:
90 Vp-p
RIng Frequency:
15-30 Hz (Reproduces the frequency detected by Unit A.)
Ring Cadence:
Reproduces the cadence detected by Unit A.
Insertion Loss:
0.0 ± 1.0 dB at 1000 Hz
(When both ports are terminated at 600
Ω
.)
Technical Specification
For use with Transition Networks Model CAPTF33xx-1xx or equivalent
Standards
FCC Part 68, TBR21
Dimensions
3.4" x 5.0" x 1.75" (86 mm x 182 mm x 43 mm)
Weight
6 oz. (0.181 g) (approximate)
Power Consumption
7.0 watts
MTBF
341,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
888,000 hours (Bellcore7 V5.0)
Environment
Tmra*:
0° to 50°C (32° to 122° F )
Storage Temp:
-15° to 65°C (-4° to 122°F)
Humidity:
5 to 95%, non condensing
Altitude:
0 to 10,000 feet
Warranty
Lifetime
*Manufacturer’s rated ambient temperature. Tmra range for this slide-in-module depends
on the physical characteristics and the installation configuration of the Transition Networks
PointSystem™ chassis in which this slide-in-module will be installed.
The information in this user’s guide is subject to change. For the most up-to-date
information on the CAPTF33xx-1xx media converter, view the user’s guide on-line at:
www.transition.com.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J
applicable at the date of manufacture.
CAUTION:
Visible and Invisible Laser Radiation When Open. Do Not Stare Into Beam Or
View Directly With Optical Instruments.
CAUTION:
Use of controls, adjustments or the performance of procedures other than
those specified herein may result in hazardous radiation exposure.
13
Click the “
Transition Now
” link for a live Web chat.
Troubleshooting
1.
Is the PWR (power) LED illuminated?
NO
•
Is the media converter slide-in-module installed properly in the
chassis?
•
Is the power cord properly installed in the chassis and at the external
power source?
•
Does the external power source provide power?
•
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
•
Proceed to step 2.
2.
Is the SDF (signal detect fiber Link) LED illuminated?
NO
•
Check the fiber cables for proper connection.
•
Verify that the TX and RX cables on the first media converter are
connected to the RX and TX ports, respectively, on the second media
converter.
•
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
•
Proceed to step 3.
3.
Is the ACT (active) LED illuminated?
NO
•
Ensure that the local unit is off-hook.
•
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
•
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.