14
C4TEF10xx-10x
Technical Support:
1-800-260-1312
International:
00-1-952-941-7600
(24 hours)
Technical Specifications
For use with Transition Networks Model C4TEF10xx-10x or equivalent.
Standards
G.703, AMI/B8ZS/HDB3
Data Rate
Fiber: 100 Mb/s
Dimensions
3.4" x 5.0" x 1.75" (86 mm x 182 mm x 43 mm)
Weight
6 oz. (181 g) (approximate)
Power Consumption
6.0 watts
Environment
Tmra*:
0 to 50°C (32 to 122°F )
Storage Temperature:
-40 to 85°C (-40 to 185°F)
Humidity:
5 to 95%, non condensing
Altitude:
to 10,000 feet
Warranty
Lifetime
*Manufacturer’s rated ambient temperature: Tmra range for this slide-in-module
depends on the physical characteristics and the installation configuration of the
Transition Networks PointSystem™ chassis in which this slide-in-module will be
installed.
The information contained in this user’s guide is subject to change. For the most
up-to-date information on the C4TEF10xx-10x media converter, see the user’s
guide on-line at: www.transition.com.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
CAUTION:
Visible and invisible laser radiation when open. Do not stare into
beam or view directly with optical instruments.
CAUTION:
Use of controls, adjustments or the performance of procedures other
than those specified herein may result in hazardous radiation exposure.
15
-- Click the
“Transition Now”
link for a live Web chat.
Troubleshooting
If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:
1.
Is the “PWR” LED illuminated?
NO
• Is the slide-in-module installed properly in the chassis?
• Is the power cord properly installed in the chassis?
• Does the external power source provide power?
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 2.
2.
Is the “LKF” LED illuminated?
NO
• Check the fiber cables for proper connection.
• Verify that the TX and RX cables on the local media converter are
connected to the RX and TX ports, respectively, on the remote media
converter.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 3.
3.
Is the “LNK” LED on a T1port (with a copper cable installed)
illuminated?
NO
• Check the copper cable connected to that T1/E1 port for proper
connection.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 4.
4.
Is the “AIS” LED on a T1/E1 port (with a copper cable installed)
illuminated?
YES
• The device connected to the T1/E1 port has failed. Correct the device
failure.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
• Proceed to step 5.