Transition Networks C4TEF1011-100 Скачать руководство пользователя страница 4

6

C4TEF10xx-10x

Technical Support: 

1-800-260-1312

International: 

00-1-952-941-7600

(24 hours)

Installation 

-- Continued

Switch Set #2 - Serial Options

6 - 

not in use

7 - 

not in use

8 - 

not in use

9 - 

not in use

switches 6, 7, 8, & 9 are not in use

9

8

7

6

10 - Fiber Loop-Back 

up 

- Disabled fiber loop-back.

down 

- Enabled fiber loop-back.  

The loop-back setting is used for installation
and network debugging procedures.  When the
fiber loop-back function is enabled, the fiber
port loops all T1/E1 signals from the receive
ports back to the transmit ports.  The loop-back
test scenarios are described in detail on page
17.

up

down

Disables Loop-Back

Enables Loop-Back

10

7

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

Installation 

-- Continued

Hardware/Software Jumper

The hardware/software header J11 is
located on the circuit board.

Use a small needle-nose pliers to
change the jumper position—currently
in the software position.

Install the Slide-in-Module 

CAUTION:  

Wear a grounding device and observe electrostatic discharge

precautions when installing the C4TEF10xx-10x slide-in-module media
converter. 

Failure to observe this caution could result in damage to, and

subsequent failure of, the slide-in-module.

1.

Carefully slide the slide-in-module into two adjacent installation slots,
aligning the module with the installation guides.  

2.

Ensure that the module is firmly seated inside the chassis.

3.

Push in and rotate the panel fastener screw clockwise to secure the
module to the chassis front.

Hardware

The media converter mode is determined by
the switch settings (see pages 3 - 6).

Software

The media converter mode is determined by
the most-recently saved, on-board
microprocessor settings.

Hardware Mode

Software Mode

S

H

S

H

Содержание C4TEF1011-100

Страница 1: ...e sent over the fiber interface simultaneously The C4TEF10xx 10x is designed to be installed in pairs For example install one C4TEF1011 100 as the local media converter and another C4TEF1011 100 as the remote media converter All C4TEF10xx 10x models have the following copper connectors The various fiber connectors are available on separate models Both duplex and single mode fiber optic converters ...

Страница 2: ... km 24 8 miles C4TEF1029 102 and C4TEF1029 103 are intended to be installed in the same link where one is the local converter and the other is the remote converter Typical maximum cable distance Actual distance is dependent upon the physical characteristics of the network TX transmit RX receive 3 techsupport transition com Click the Transition Now link for a live Web chat Installation Continued Co...

Страница 3: ...rier signal This function is un framed and applies to ALL channels both copper and fiber down Disables the transmit AIS function 10 RS 232 Port Mode up Data port mode normal operation Transmits data to a desk top computer or other data collection device down Local auxiliary management mode See the SNMP section page 11 for the commands that are supported via the RS 232 connector up down Enable Disa...

Страница 4: ...Jumper The hardware software header J11 is located on the circuit board Use a small needle nose pliers to change the jumper position currently in the software position Install the Slide in Module CAUTION Wear a grounding device and observe electrostatic discharge precautions when installing the C4TEF10xx 10x slide in module media converter Failure to observe this caution could result in damage to ...

Страница 5: ...nnector to the media converter as shown Connect the DB 9 connector to the computer RS 232 data cable enclosed Dry Contact Relay All four T1 E1 ports are equipped with an RJ 48 dry contact relay The relay closes if the power is lost or if any of the individual T1 E1 links are lost The operational rating on pins 3 and 6 are 0 30 VDC 100 mAmp maximum relay 3 6 RJ 48C connector T1 E1 port 9 techsuppor...

Страница 6: ...e to a local C4TEF10xx 10x slide in module media converter that is installed in a managed Transition Networks PointSystem chassis See the list of SNMP commands below SNMP See the on line documentation that comes with Transition Networks FocalPoint software for applicable commands and usage Use SNMP at an attached terminal or at a remote location to monitor the media converter by monitoring Media c...

Страница 7: ...nsmitter Power min 19 0 dBm max 14 0 dBm Fiber Optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm Link Budget 11 0 dB C4TEF1013 100 1300 nm multimode Fiber Optic Transmitter Power min 19 0 dBm max 14 0 dBm Fiber Optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm Link Budget 11 0 dB C4TEF1014 100 1310 nm single mode Fiber optic Transmitter Power min 15 0 dBm max 8 0 dBm Fiber optic Receiver Sen...

Страница 8: ...ols adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure 15 techsupport transition com Click the Transition Now link for a live Web chat Troubleshooting If the media converter fails isolate and correct the failure by determining the answers to the following questions and then taking the indicated action 1 Is the PWR LED illuminat...

Страница 9: ... mode enter the local T1 E1 loop back command at the remote converter Use a bit error test unit to run a bit error test Fiber T1 T1 Local Converter Remote Converter Bit Error Test Equipment Remote Device Fiber T1 T1 Local Converter Remote Converter Bit Error Test Equipment Remote Device Fiber T1 T1 Local Converter Remote Converter Remote Device Bit Error Test Equipment Fiber T1 T1 Local Converter ...

Страница 10: ...diate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed ...

Страница 11: ...their respective owners Copyright Restrictions 2005 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks Printed in the U S A 33306 C ...