background image

CABLE SPECIFICATIONS

The physical characteristics of the media cable must meet or exceed IEEE 802.3
specifications. 

Fiber Cable 

MULTIMODE

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber

Wavelength :

850 nM

Attenuation:

3.75 dB/ 1 kilometer @ 850 nM 

Fiber-optic Transmitter Power:

min: -16.0 dBm

max: -10.0 dBm

Fiber-optic Receiver Sensitivity:

min: -29.50 dBm

max: -7.2 dBm

Link Budget

13.5 dB

Typical Maximum Cable Distance:*

Full-duplex: 300 meters

Half Duplex: See page 4

*Actual distance dependent upon physical characteristics of network installation.

Copper Cable

Category 5 twisted-pair copper wire is required. Either shielded twisted-
pair (STP) or unshielded twisted-pair (UTP) can be used. DO NOT USE
FLAT OR SILVER SATIN WIRE.

CATEGORY 5:

Gauge

24 to 22 AWG

Attenuation 

22.0 dB /100m @ 100 MHz

Maximum Cable Distance:

100 meters

RJ-45 Pin-out::

Pin 1=TD+, Pin 2=TD-,
Pin 3=RD+, Pin 6=RD-

Twisted pair connection requires two active pairs configured as straight
through and/or crossover. The two active pairs in an Ethernet™ network
are pins 1 & 2 and pins 3 & 6. Use only dedicated wire pairs (such as
blue/white & white/blue, orange/white & white/orange) for the active pins.

Use the the C/E-TX-SX-02 media converter to extend the distance between a
10BASE-T or a 100BASE-TX terminal device and a 10BASE-FL or a 
100BASE-SX (half-duplex only) hub, switch, or router:

Or use the the C/E-TX-SX-02 media converter to extend the distance between
a 10BASE-T or a 100BASE-TX hub, switch, or router and a 10BASE-FL or a
100BASE-SX terminal device:

Crossover 

1
2

3
6

Straight Through 

Twisted Pair #1

Twisted Pair #1

Twisted Pair #2

Twisted Pair #2

1
2

3
6

1
2

3
6

1
2

3
6

 UTP/STP

Fiber

up to 300 meters - multimode

up to 100 meters 

 UTP/STP

Fiber

up to 300 meters - multimode

up to 100 meters 

Содержание C/E-TX-SX-02

Страница 1: ...rs etc Read the instructions for correct handling Trademark Notice All registered trademarks and trademarks are the property of their respective owners Copyright Restrictions 2000 TRANSITION Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Printed in the U S A...

Страница 2: ...ance between two 10BASE T or 100BASE TX devices TECHNICAL SPECIFICATIONS Standards IEEE 802 3 Compliant with pending TIA EIA 785 specification Environment Temperature 0 40 C 32 to 104 F Storage Temperature 15 to 65 C 5 to 149 F Humidity 10 90 non condensing Altitude 0 10 000 feet Warranty Lifetime DECLARATION OF CONFORMITY Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344...

Страница 3: ...TEGORY 5 Gauge 24 to 22 AWG Attenuation 22 0 dB 100m 100 MHz Maximum Cable Distance 100 meters RJ 45 Pin out Pin 1 TD Pin 2 TD Pin 3 RD Pin 6 RD Twisted pair connection requires two active pairs configured as straight through and or crossover The two active pairs in an Ethernet network are pins 1 2 and pins 3 6 Use only dedicated wire pairs such as blue white white blue orange white white orange f...

Страница 4: ...ity LED illuminated NO If there is no activity on the 10 100BASE TX port proceed to step 7 If there is activity on the 10 100BASE TX port disconnect and reconnect the 10 100BASE TX cable to restart the initialization process Restart the workstation to restart the initialization process Contact Technical Support 800 260 1312 YES Proceed to step 7 7 Is the 10 100SX ACT ivity LED illuminated NO If th...

Страница 5: ...ISTENT disconnect and reconnect either cable to restart the initialization process If the fault is not corrected proceed to step 6 INSTALLATION Install Slide In Module in E MCC 1600 Chassis NOTE Media Converter Slide in Modules can be installed in any installation slot in any order Remove Media Converter Slide in Module protective plate from selected installation slot by removing screw that secure...

Страница 6: ...used when connecting to 10BASE T or to 100BASE TX devices such as hubs transceivers or network interface cards NICs AutoCross determines the characteristics of the cable connection and automatically configures the unit to link up regardless of the cable configuration Requires no operator intervention Using Autonegotiation The C E TX SX 02 series media converter Autonegotiation feature allows the m...

Отзывы: