C/E-TBT-FRL-04 IN THE NETWORK
Use the C/E-TBT-FRL-04 media converter (or two C/E-TBT-FRL-04 media
converters in pairs) to connect a workstation to a remote hub or to connect two
hubs, switches, or workstations.
NOTE: Maximum Number of Nodes:
2 nodes
The AutoCross™ feature allows either straight-through or crossover cables to be
used when connecting to 10BASE-T devices, such as hubs, transceivers, or
network interface cards (NICs). AutoCross™ determines the characteristics of
the cable connection and automatically configures the unit to link up to straight-
through or to crossover cable.
The LinkALERT™ feature allows the C/E-TBT-FRL-04 media converter to pass
10BASE-T side link faults to the 10BASE-FL side and to pass 10BASE-FL side link
faults to the 10BASE-T side. NOTE: An enable/disable switch allows the network
administrator to disable LinkALERT™ in the case of a network with back-to-
back media converter installation in which Autonegotiation from other sources
does not work properly.
TECHNICAL SPECIFICATIONS
Standards
IEEE 802.3
Dimensions
4.7" x 3.0" x 1.0" (119 mm x 76 mm x 25 mm)
Environment
Temperature
0 to 50°C (32° to 122° F )
Storage Temperature
-20 to 85°C
Humidity
5-95%, non condensing
Altitude
0-10,000 feet
Warranty
Lifetime
DECLARATION OF CONFORMITY
Name of Mfg:
Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA
Model:
C/E-TBT-FRL-04 Series 10BASE-T/10BASE-FL Media Converter
Part Number:
C/E-TBT-FRL-04, C/E-TBT-FRL-04(SC), C/E-TBT-FRL-04(SM), C/E-TBT-FRL-04(L),
C/E-TBT-FRL-04(MT), C/E-TBT-FRL-04(LH), C/E-TBT-FRL-04(XC)
Regulation:
EMC Directive 89/336/EEC
Purpose: To declare that the C/E-TBT-FRL-04 to which this declaration refers is
in conformity with the following standards.
EMC-CISPR 22: 1985 Class A; EN 55022: 1988 Class A; EN 50082-1:1992;
EN 60950 A4:1997; IEC 801.2, IEC 801.3, and IEC 801.4; IEC 950
I, the undersigned, hereby declare that the equipment specified above conforms to the
above Directive(s) and Standard(s).
_July 7, 1999_____
Stephen Anderson, Vice-President of Engineering
Date
2 kilometers - 850 nM multimode
100 meters
100 meters
20 kilometers - 1300 nM singlemode
5 kilometers - 1300 nM multimode
Twisted
Pair #1
Twisted
Pair #2
Crossover Cable
Connectors for like devices
Twisted
Pair #1
Twisted
Pair #2
Straight Through Cable