C/E-TBT-FRL-04 IN THE NETWORK

Use the C/E-TBT-FRL-04 media converter (or two C/E-TBT-FRL-04 media
converters in pairs) to connect a workstation to a remote hub or to connect two
hubs, switches, or workstations.

NOTE: Maximum Number of Nodes:

2 nodes

The AutoCross™ feature allows either straight-through or crossover cables to be
used when connecting to 10BASE-T devices, such as hubs, transceivers, or
network interface cards (NICs). AutoCross™ determines the characteristics of
the cable connection and automatically configures the unit to link up to straight-
through or to crossover cable. 

The LinkALERT™ feature allows the C/E-TBT-FRL-04 media converter to pass
10BASE-T side link faults to the 10BASE-FL side and to pass 10BASE-FL side link
faults to the 10BASE-T side. NOTE: An enable/disable switch allows the network
administrator to disable LinkALERT™ in the case of a network with back-to-
back media converter installation in which Autonegotiation from other sources
does not work properly.  

TECHNICAL SPECIFICATIONS

Standards

IEEE 802.3

Dimensions

4.7" x 3.0" x 1.0" (119 mm x 76 mm x 25 mm)

Environment

Temperature

0 to 50°C (32° to 122° F )

Storage Temperature

-20 to 85°C

Humidity

5-95%, non condensing 

Altitude

0-10,000 feet

Warranty

Lifetime

DECLARATION OF CONFORMITY

Name of Mfg:

Transition Networks 
6475 City West Parkway, Minneapolis MN 55344 USA

Model:

C/E-TBT-FRL-04 Series 10BASE-T/10BASE-FL Media Converter

Part Number:

C/E-TBT-FRL-04, C/E-TBT-FRL-04(SC), C/E-TBT-FRL-04(SM), C/E-TBT-FRL-04(L),
C/E-TBT-FRL-04(MT), C/E-TBT-FRL-04(LH), C/E-TBT-FRL-04(XC)

Regulation:

EMC Directive 89/336/EEC

Purpose:  To declare that the C/E-TBT-FRL-04 to which this declaration refers is

in conformity with the following standards.

EMC-CISPR 22: 1985 Class A;  EN 55022: 1988 Class A;  EN 50082-1:1992;
EN 60950 A4:1997;  IEC 801.2, IEC 801.3, and IEC 801.4;  IEC 950

I, the undersigned, hereby declare that the equipment specified above conforms to the

above Directive(s) and Standard(s).

_July 7, 1999_____

Stephen Anderson, Vice-President of Engineering

Date

2 kilometers - 850 nM multimode 

100 meters

100 meters

20 kilometers - 1300 nM singlemode 

5 kilometers - 1300 nM multimode 

Twisted
Pair  #1

Twisted
Pair  #2

Crossover Cable

Connectors for like devices

Twisted
Pair  #1

Twisted
Pair  #2

Straight Through Cable

Connectors for unlike devices

Содержание C/E-TBT-FRL-04(L)

Страница 1: ...TBT FRL 04 10BASE T 10BASE FL media converters designed to be installed in the E MCC 1600 Media Conversion Center connect either half duplex or full duplex unshielded or shielded 10BASE T twisted pair copper to either half duplex or full duplex 10BASE FL singlemode or multimode fiber CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK Failure to observe this cauti...

Страница 2: ...ions 4 7 x 3 0 x 1 0 119 mm x 76 mm x 25 mm Environment Temperature 0 to 50 C 32 to 122 F Storage Temperature 20 to 85 C Humidity 5 95 non condensing Altitude 0 10 000 feet Warranty Lifetime DECLARATION OF CONFORMITY Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model C E TBT FRL 04 Series 10BASE T 10BASE FL Media Converter Part Number C E TBT FRL 04 C E TBT FRL 0...

Страница 3: ...onnector Twisted pair connection requires two active pairs configured as straight through The two active pairs in an Ethernet network are pins 1 2 and pins 3 6 Use only dedicated wire pairs such as blue white white blue orange white white orange for the active pairs Category 3 or better twisted pair copper wire is required Either shielded twisted pair STP or unshielded twisted pair UTP can be used...

Страница 4: ...n page 7 Is the power adapter properly installed in the media converter and in the outlet Contact Technical Support 800 260 1312 800 LAN WANS YES Proceed to step 2 2 Is the 10BASE T Link LED illuminated NO Check twisted pair cables for proper connection Contact Technical Support 800 260 1312 800 LAN WANS YES Proceed to step 3 3 Is the 10BASE FL Link LED illuminated NO Check fiber cables for proper...

Отзывы: