background image

C/E-PSW-SX-01

Connecting Twisted-Pair Copper Cable to UTP/STP
Connector (10BASE-T/100BASE-TX)

Ensure that the correct cable type is installed to support the highest speed
and mode of operation to be selected. Though Category 3 cable is
adequate for the 10BASE-T installation, Category 5 cable is strongly
recommended, since Category 3 cable can NOT be used for 100BASE-TX.

10BASE-T AND THE ETHERNET COLLISION DOMAIN

Refer to the 5-Segment Rule (page 6) before installing half-duplex
10BASE-T cable.

Installing full-duplex twisted-pair cable avoids collision domain
considerations; distances remain 

100 meters. 

100BASE-TX AND THE FAST ETHERNET COLLISION DOMAIN

Refer to the 512-Bit Rule (page 7) before installing half-duplex
100BASE-TX cable.

Installing full-duplex twisted-pair cable avoids collision domain
considerations; distances remain 

100 meters. 

NOTE: A Fast Ethernet collision domain can have ONLY ONE
CLASS I repeater OR TWO CLASS II repeaters.

INSTALLING CABLE
To install 10BASE-T or 100BASE-TX cable:

1. Locate or build 10BASE-T or 100BASE-TX cables:

803.2 (10BASE-T) or 803.2u (100BASE-TX) compliant (page

11)

with Straight-through or Crossover RJ-45 cable/connectors as

required for site installation (page 7)

with RJ-45 plug connectors installed at both cable ends.

2. Connect RJ-45 plug connector at one end of 10BASE-T or

100BASE-TX cable to bridging media converter RJ-45 jack
connector.

3. Connect RJ-45 plug connector at other end of 10BASE-T or

100BASE-TX cable to RJ-45 jack connector on network device.

Installing Slide-In-Module(s)

CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing Media Converter Slide-in-Module(s) in the
Media Conversion Center. Failure to observe this caution could result in
damage to, and subsequent failure of, the Media Converter Slide-in-
Module(s).
NOTE: Slide-in-Modules can be installed in any installation slot, in any
order.
To install the Media Converter Slide-in-Module in the E-MCC-1600
chassis:

1. Remove Media Converter Slide-in-Module protective plate from

selected installation slot by removing two screws that secure plate to
front of E-MCC-1600. 

2. Carefully slide Media Converter Slide-in-Module into installation

slot, aligning Media Converter Slide-in-Module with installation
guides. 

NOTE: Ensure that the Media Converter Slide-in-Module is seated
firmly against the backplane.

3. Secure Slide-in-Module to E-MCC-1600 chassis by rotating captive

screw attached to Slide-in-Module clockwise into chassis.

Power Modules

Media

Conversion

Center

E-MCC-1600

Power

In Use

Power

In Use

1

2

Management

Module

Power

Link

TX

RX

Содержание C/E-PSW-SX-01(SC)

Страница 1: ...cal without written permission from TRANSITION Networks Trademark Notice All registered trademarks and trademarks are the property of their respective owners 33104 B Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften d...

Страница 2: ...ILVER SATIN WIRE Category 3 Gauge 24 to 22 AWG Attenuation 6 5 dB 100 10 MHz Differential Characteristic Impedance 100 Ω 15 Category 5 Gauge 24 to 22 AWG Attenuation 22 dB 100 100 MHz Differential Characteristic Impedance 100 Ω 15 Maximum Cable Distance 100 meters 330 feet 11 2 Link UTP STP Fiber Link FDX Power 100 10BASE T 100BASE SX RATE CONVERSION The two port Ethernet Fast Ethernet bridging me...

Страница 3: ...tings shown below are set to configure the bridging media converter for the site installation To set network speed s and operating mode s use a VERY small flatblade screwdriver or similar device and refer to the table at the left and to the examples on the next page to set DIP switch for the site installation NOTE Auto negotiation is designed so that a twisted pair link will not become operational...

Страница 4: ... domain considerations and extends distances up to 2 kilometers multimode or up to 20 kilometers singlemode NOTE A Fast Ethernet collision domain can have ONLY ONE CLASS I repeater OR TWO CLASS II repeaters INSTALLING CABLE To install 100BASE SX cable 1 Locate or build 100BASE SX cables 100BASE SX compliant page 11 with male transmit TX and receive RX fiber connectors installed at both cable ends ...

Страница 5: ...age 7 with RJ 45 plug connectors installed at both cable ends 2 Connect RJ 45 plug connector at one end of 10BASE T or 100BASE TX cable to bridging media converter RJ 45 jack connector 3 Connect RJ 45 plug connector at other end of 10BASE T or 100BASE TX cable to RJ 45 jack connector on network device Installing Slide In Module s CAUTION Wear a grounding device and observe electrostatic discharge ...

Страница 6: ...arates collision domain so the 512 bit rule applies separately to each 100BASE TX or 100BASE SX half duplex collision domain A segment is the cable connection between interfaces A transmission path between any two terminal devices including the Transition Networks Switch in the same collision domain can consist of no more than five segments To assign segment numbers to cable connections determine ...