Air Outlet Assembly
A. Line up the plastic latches with the corresponding
grooves of the unit.
B. Press the top and bottom of the front cover in
and lightly push the front cover down
C. Make sure the cover is locked in to the unit.
B
C
Caution: BFN series products have safety relay
switches where the front and rear fan guards at-
tach to the unit. These relays disable the fan/
ionizer operation when either fan guard is re-
moved. Take care when attaching the fan guards
to assure proper functioning of the product.
Periodic Verification:
BFN ionizer have no user serviceable parts and the technol-
ogy requires no calibration because of the inherently stable
ionization output from the AC emission. Periodic verification
is recommended, per ANSI/ESD SP3.3-2006 Periodic Verifi-
cation of Air Ionizers. Verification frequency may be set by
the individual user, but is recommended to be not less than
one time per year.