Transforming Technologies BFN 802 Скачать руководство пользователя страница 5

Product Specifications 

Packing list:

 

 

BFN 802 ionizing blower 

 

Power cord 

 

Instruction manual 

 

Certificate of Conformance 

Power Requirements 

120 V AC, 60 Hz., 70W 
220 V AC, 50Hz. 

 

Dimensions

 

 

 

23” W x 6.75” H x 3.35” D 

 

(58.5 W x 17.2 H x 8.5 D cm)

 

 

Weight

 

 

 

12.8 lb (5.8 kg)

 

 

Air Volume

  

 

100 CFM 

 200 CFM [low 

high]

 

 

Effective Coverage 

2’ x 3’ area coverage

 

 

Balance

 

 

 

0

 

+10 volts

 

 

Decay Time

  

 

< 3 seconds @ 18”, directly 

under center of unit, 1000V-
100V, 
fan speed on high

 

 

Temperature

 

 

 

32-122° F (0-50° C) 

RH Operating Range 

 

20-60%, non-condensing  

Ozone Production 

 

< 0.003 ppm, 12” in front of 

unit, EPA EQOA577019

 

 

Indicators

   

 

ON/OFF status light  indica-
tor, detects presence of HV 
on emitter points

 

 

Light Output 

 

 

825 Lumens 

 

Light Color Temperature 

2500 K 

 

Replacement Lamp 

 

T4/5W fluorescent lamp

 

  

Audible Noise

 

 

48dB(A), (Distance 1 meter) 

 

Enclosure

   

 

Steel 

 

Finish 

 

 

 

Powder Coat, off white

 

 

Approvals

   

CE

 

Содержание BFN 802

Страница 1: ...T R A N S F O R M I N G T E C H N O L O G I E S L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L Static Eliminators BFN 802 Ionizing Blower Instruction Manual BFN...

Страница 2: ...FN 802 BFN Series 1 Description 2 Features 2 Specification 3 Operating Guide 4 Dis Assembly 6 Bulb Replacement 8 Periodic Verification 9 2 About Service warranty 10 Transforming Technologies 10 Conten...

Страница 3: ...AC ionizing blowers are designed for safe operation under normal use Safety switches under the front and rear removable finger guards shut off the unit protecting the operator during maintenance Do no...

Страница 4: ...ped with task lighting integrated emitter cleaners and safe easy maintenance access BFN series AC ionizers from Transforming Technologies create a dense and well balanced ionization current They are u...

Страница 5: ...ea coverage Balance 0 10 volts Decay Time 3 seconds 18 directly under center of unit 1000V 100V fan speed on high Temperature 32 122 F 0 50 C RH Operating Range 20 60 non condensing Ozone Production 0...

Страница 6: ...and connect the power cord Rotate the on off fan speed knob clockwise to turn on the unit Continue rotat ing the knob to achieve the desired fan speed Note Do not insert any object into the air inlet...

Страница 7: ...nt is on the bottom right of fan guard Do Not Force Internal fan cleaning All BFN series ionizing blowers offer convenient cleaning of the internal fan assembly Use the following procedure to maintain...

Страница 8: ...Cleaning Cont After removing both front and rear fan guards the emitter points and fan assembly will be unob structed for easy deep cleaning Use a soft brush Isopropyl Alcohol and compressed air to re...

Страница 9: ...attached C Press the sides of the cover in to make sure cover is securely attached A B C Air Inlet Assembly A Line up the clips on the rear fan guard with the slots on the BFN fan housing B Push the...

Страница 10: ...ask lights to eliminate the work station and improve worker efficiency The unit comes with two 5W bulbs already installed Bulb Replacement Procedure Note Always disconnect the ionizer from the power s...

Страница 11: ...ly stable ioniza tion output from the AC emission Periodic verification is rec ommended per ANSI ESD SP3 3 2006 Periodic Verification of Air Ionizers Verification frequency may be set by the individ u...

Страница 12: ...collateral or conse quential damages To receive service under warranty please contact Transforming Technologies Technical Sup port About Transforming Technologies Since 1998 Transforming Technologies...