8
Caution: BFN series products have safety relay
switches where the front and rear fan guards attach
to the unit. These relays disable the fan/ionizer op-
eration when either fan guard is removed. Take care
when attaching the fan guards to assure proper func-
tioning of the product.
Bulb Replacement
The BFN 802 comes with two task lights to eliminate the work
station and improve worker efficiency. The unit comes with
two 5W bulbs already installed.
Bulb Replacement Procedure.
Note:
Always disconnect the ionizer from the power source
prior to replacing bulbs.
A. Remove light cover by sliding cover to the left to
release locking clasps.
B. Carefully lift cover off of casing to reveal bulb.
A
B
C. Hold bulb by metal ends and turn the bulb 90 degrees.
Carefully lift bulb out of unit.
D. Insert new bulb into bulb holder and rotate 90 degrees
to lock in bulb.