5.2 Move, switch the cursor and set the mark point

Set the position of the mark points through moving the position of the cursor. Move the current activated

cursor to the left and right via the navigation key

or

. When continuously hold the key

or

and moving 10 data points, the active cursor will move rapidly and move 10 data points

each time. Release the key

or

, then the active cursor will stop moving; or directly click on

the touch screen and move the currently activated cursor to the appropriate touch point. Press the key

of the navigation keys to switch the cursor points.

5.3 Zooming and shift of waveform curve

To facilitate users to carry out manual analysis on the tested curve, when the test of 5302 Series OTDR

is over, the menu key is placed on horizontal zoom-in and zoom-out

of the curve operating menu

in default, and at this time, just directly press the navigation keys

and

to realize the

horizontal zoom-in and zoom-out of the test curve in the center of currently activated cursor. At this time,

the key

or

in the navigation keys can be shifted left or right to move the cursor.

When continuously pressing the key

in the menu operating keys, or clicking on the curve

operating menu in the touch screen, at this time, this menu can realize the alternative switching among

,

and

.

6. Visual red light fault positioning

With the built-in high-power visual red light fault positioning function, 5302 OTDR can discover the
breakpoint of the short-distance optical fiber link or the position of a large loss point very conveniently and
intuitively. Combing with OTDR function, it can realize the seamless monitoring of the link test so that the
maintenance personnel can discover the problems of the links timely and take measures to save the test
time.
There are two output modes for the visible red light of 5302sOTDR:

DC mode;

AC mode.

In the OTDR test main interface, when the OTDR is under the non-test status, press and hold the key

for about 2s, the light is on, indicating that the visual fault positioning function is started and the

working mode is DC mode; press this key once again, the light of the key flickers and the working mode
of the visual fault positioning function is changed to AC mode; press this key again, the visual fault

positioning function is closed and the light of the key is off. If pressing the key

to start the OTDR

Содержание 5302 Series

Страница 1: ...Domain Reflectometer ITEM NAME QUANTITY Host machine 5302 Optical Time Domain Reflectometer 1 Standard accessories Power cord 1 Power adapter 1 User manual 1 CD containing 5302 simulation analysis so...

Страница 2: ...ce of the battery please charge the instrument with the internal battery and use up the electric quantity before using this instrument and then charge the battery The first time of charging should be...

Страница 3: ...oduction OTDR is a precise optical measuring instrument made according to the backscatter principle of Rayleigh scattering and Fresnel reflection when the transmission of laser in the optical fiber It...

Страница 4: ...ight energy will return along the optical fiber to the instrument Through receiving this reflected signal the instrument will detect this reflection event which will be presented as upward spike signa...

Страница 5: ...tly look at the corresponding light output interface 3 2 5302 OTDR Power Supply Interface 5302 Series OTDR power port is on the right side of the instrument Input requirement 19V 1V 2 A Polarity posit...

Страница 6: ...rt the different sub windows to realize the corresponding functions Details see the operation method Figure 2 6 the OTDR main operating window diagram The description of notes is as follows 1 the OTDR...

Страница 7: ...es OTDR which respectively waveform operation parameter setting curve save file operation system information help from left to the right 4 2 Description of the OTDR button functions The functions of v...

Страница 8: ...o the left to select the system time and language under the system information sub interface Key Move the current cursor to the right under the main operating window Move the parameter options downwar...

Страница 9: ...ivalent to the key Key OTDR testing and stop key When the OTDR operating interface displays as the main operating window press down this button to start the OTDR module to test the optical fiber and d...

Страница 10: ...icient and event threshold value etc In the main operating interface move the cursor to the parameter setting menu through the menu operating key or then press the key the parameter setting interface...

Страница 11: ...lay the test results to perform dynamic monitoring on the links before and after connection conveniently Average test is to accumulate the scan results for many times and perform average processing wh...

Страница 12: ...touch screen Event Threshold window and press the key or to select the threshold value and press the key to save the setting and exit the window IOR Refractive index The refractive index of the optica...

Страница 13: ...ave the setting and exit the window Light To set the light of LCD Setting method Under the parameter setting interface move the cursor to the option Event Llight via the navigation key or or directly...

Страница 14: ...down the key OTDR can perform average test on the the tested optical fibre link according to the set test parameters and the test curves in the main operating window will be subject to average proces...

Страница 15: ...two sides of the event respectively Move the small cursor at the front of cursor A to the far end of the previous segment of linear area of the event to be tested linear area A and move the small cur...

Страница 16: ...ording to the set event threshold value to obtain the length loss average loss and other information of the optical fiber links Besides display the event point information at the event list column in...

Страница 17: ...ated cursor At this time the key or in the navigation keys can be shifted left or right to move the cursor When continuously pressing the key in the menu operating keys or clicking on the curve operat...

Страница 18: ...and related information of curve In the main interface of test select the menu via the menu operation key or press the and the curve save window will pop up Fig 2 16 5302 OTDR file save Navigation ke...

Страница 19: ...ead path is U disk copy the U disk files to the internal memory key select the operation path which can be divided into two types internal memory and U disk or key used to select the operation files k...

Страница 20: ...the cursor to select the operation item or key used to modify the parameters of the operation item Press the key to confirm the operation and exit the window Press the key to delete the operation and...

Страница 21: ...ctricity through the battery when the battery is completely discharged charge the battery The first time of charging time should be more than 8 hours For your safety use multiple protection measures o...

Страница 22: ...the supplier to replace the battery The normal curves cannot be tested 1 The instrument parameters are not set correctly 2 The optical fiber output end face is contaminated 3 The instrument light outp...

Страница 23: ...e the event threshold value The measured length of the optical fiber is not accurate 1 The instrument parameters are not set correctly 2 The refractive index of the optical fiber is not set accurately...

Страница 24: ...The USB interface functions can quickly realize the file transfer and report form preparation The universal light output connector is easy to replace which is able to realize e a variety of interface...

Страница 25: ...Series OTDR Table 4 1 Technical Specification of 5302 Series OTDR Model Item 5302 series S1 S2 S3 M1 Type of optical fiber Single mode Multi mode Center wavelength 1310nm 1550nm 20nm 850nm 1300nm 20nm...

Страница 26: ...V 1 5A 50 60Hz DC 18V to 20V 2A Internal lithium ion battery pack 7 4V 4400mAh Battery operation time 3 10hours Operating temperatur e 5 50 Storage temperatur e 20 70 Relative humidity 0 95 no condens...

Страница 27: ...78677 Fax 86 755 26029402 Web www sz transcom com No Name Qty 1 Host of 5302 series handheld OTDR 1 2 Power cord 1 3 AC DC power adapter 1 4 Certificate 1 5 User manual 1 6 CD ROM including simulation...

Отзывы: