background image

 

12 

4.2.5 Set ID NO. 

Enter into the main menu by press MENU button, then pressing UP / DOWN to 

choose the 

Set ID NO. 

option, then press the ENTER to confirm your selection. 

Press the ID No. (for example: 001) and press the ENTER to enter and press 

UP and DOWN to choose the ID No. for the unit from 000 to 255. The ID is only 

used to recognize each of the unit easily. 

 

4.2.6 Set LCD Backlight 

Enter into the main menu by press MENU button, then pressing UP / DOWN to 

choose the 

Set LCD Backlight 

option and then press the ENTER to confirm 

your selection. You can choose its status as ON/OFF. 

“ON” means the LCD 

backlight will turn on all the time. 

“OFF” means the LCD backlight will turn off 

automatically after idle 30 seconds. 

 

4.2.7 User Preset 

Enter into the main menu by press MENU button, 

then pressing UP / DOWN to choose the

   

User Preset 

option and then press the ENTER   

to confirm your selection. This setting help you 

easily use the application avoid complicated   

setup procedure. You can simply choose you 

desired mode by pressing UP and DOWN. 

 

Содержание Art-Net N4 MKII

Страница 1: ...Order code CONT25 User Guide Please read these instructions carefully before use N4 MKII Art Net Node...

Страница 2: ...Rear View 4 4 Operation Guide 5 4 1 Startup View 5 4 2 Main Menu 6 4 2 1 Rename Device 7 4 2 2 Set IP Address 7 4 2 3 Set Netmask 8 4 2 4 Set DMX Port 8 4 2 5 Set Device ID Number 12 4 2 6 Set LCD Ba...

Страница 3: ...EC power input 19 1U rack mountable Power supply 100 240V 50 60Hz Dimensions 45 x 484 x 152mm Weight 1 98kg Please note Knowledge of DMX and Art NetTM is required to fully utilise this unit Please use...

Страница 4: ...y a qualified technician in accordance with local territory regulations The safety of the installation is the responsibility of the installer The fixture presents risks of severe injury or death due t...

Страница 5: ...ent it will flash 4 LCD Display Display the present status and the available option 5 MENU Button 6 UP DOWN Button 7 ENTER Button Enter into main menu or back to last menu UP and DOWN Enter and Confir...

Страница 6: ...ork In addition the N4 ArtNet can be used as a DMX merger DMX splitter backup device and so on 4 1 Startup View There are 4 different statuses as pictures show you can check when you power on your uni...

Страница 7: ...6 4 2 Main menu Net 001 128...

Страница 8: ...er into the main menu by press MENU button then pressing UP DOWN to choose the Set IP Address option and then press the ENTER to confirm your selection Now you can set IP address by pressing UP and DO...

Страница 9: ...u can set Netmask by pressing UP and DOWN now Confirm you change and move to next option by pressing the ENTER and UP DOWN 4 2 4 Set DMX port Enter into the main menu by press MENU then pressing the U...

Страница 10: ...r backup Normal mode means it will send the data received from DMX IN port to the universe of network regardless if there is any data in the universe of the network Backup mode In backup mode the N4 w...

Страница 11: ...port output should be 0 Single means this port will only output one universal LTP means this port will output the latter one between the universal of principle and secondly The unit will compare the...

Страница 12: ...ou should ensure the Resend option is not at the status of Disabled Or it won t resend the data to the network RDM means the port output can support Remote Device Manager 3 1 4 DMX port disabled Any o...

Страница 13: ...ss MENU button then pressing UP DOWN to choose the Set LCD Backlight option and then press the ENTER to confirm your selection You can choose its status as ON OFF ON means the LCD backlight will turn...

Страница 14: ...h LTP or HTP modes 2 DMX Split 1 3 This setting allows the user to input one DMX signal and replicate across 3 isolated DMX outputs Please note that the LED indicator of the DMX Output port will light...

Страница 15: ...tput across 4 universes The port range of DMX outputs is 1 4 0 0 0 7 Each will receive the signal from the network individually 5 Factory Reset All of the setting including the device name and device...

Страница 16: ...gram Please Note that The unit cannot be circular connected or it will cause cyber storm to affect the performance of system Technical Specification Power Supply AC100 240V 50 60Hz Dimensions 44x484x1...