background image

16 

 

 

 
Battery in digital indicator need to be recharged or 
replaced 

and 

both TI-500 RFTM batteries need to 

be replaced. 

Err 24 

Value for SP1 is greater than value for SP2. 

Err 99 

Parameter menus blocked. Toggle calibration 
switch back to its original position. 

No-ad 

Weighing platform not detected 

 

SPECIFICATIONS 

 
Digital Indicator Specifications – TI-700 

- ABS enclosure rated for IP67 
- 1.0”, 7-digit reverse LCD w/LED backlight 
- Operating temperature -4°F to 104°F (-20°C to 40°C) 
- Internal connection port for optional printer 
- Tilt adjustable bracket included 
- AC Power: 90-308 VAC, 50/60 Hz 
- DC Power: 5-15 VDC 
 

 
OPTIONAL Bluetooth Specifications (RFTM) 

- 2.0, Class I 
- Up to 100m unobstructed  
- (ISM) band at 2.4 to 2.485 GHz 

 
Optional Digital Indicator Battery – TI-700  

- 7.4 volt 3 Ah internal Li-Ion rechargeable battery 
- 85+ continuous hours of operation on full charge under typical operating conditions 

 
 
OPTIONAL TI-500 RFTM Battery Holder 

- Holds 1.5-volt x 4 “C” alkaline 
- User replaceable 
- 130+ continuous hours of operation under typical operating conditions 

 

 

Содержание TI-700

Страница 1: ...MODEL TI 700 Digital Weight Indicator with wireless weighing capability User Manual Revision 3 0 July 31 2017...

Страница 2: ...the batteries TI 500 RFTM 5 Optional Rechargeable battery information 5 Balance of this page intentionally left blank 6 DISPLAY KEYPAD DETAILS 7 ADVANCED OPERATION 9 Hold operation 9 NET Weighing 9 Pi...

Страница 3: ...UIPMENT CONTAINS NO USER SERVICEABLE COMPONENTS Servicing of the equipment must only be carried out by trained and authorized personnel Use only the AC adapter supplied with the scale Other adapters m...

Страница 4: ...old with an external TI 500 RFTM Radio Frequency Transceiver Module and an op tional wireless radio your TI 700 indicator is transformed from wired to cable free This config uration is depicted in the...

Страница 5: ...sure press the UNITS key repeatedly un til it is indicated e g lb for pounds kg for kilograms etc The indicator features an automatic zero correction meaning that small deviations will be zeroed autom...

Страница 6: ...he indicator for the first time please charge the battery overnight The indicator s battery should operate for about 85 hours if left on continuously The display unit is configured to power down after...

Страница 7: ...th a pre installed power connector and an external battery charger Simply link the two up and plug the battery charger into a suitable AC wall outlet Note that the external battery charger is rated fo...

Страница 8: ...P Indicates that the indicator is in PEAK HOLD mode lb Indicates that the unit of the displayed weight is in pounds kg Indicates that the unit of the displayed weight is in kilograms g Indicates that...

Страница 9: ...Tare weight has been established first Tare This key is used to establish a Tare weight provided the following conditions are met 1 The indicator is displaying a Gross weight above zero 2 The scale i...

Страница 10: ...values only PEAK HOLD F35 3 The display updates as the load increases but not as the load de creases The value shown on the screen is the maximum weight applied to the scale Press the UNITS key to tog...

Страница 11: ...rs Available choices are 5 10 20 50 and 100 If you continue to push the UNITS key the indicator will resort back to weighing mode and you must start again from Step 2 3 Place the sample items on the p...

Страница 12: ...e The system needs to be returned to the net zero range before another weight can be added 6 The subtotal can be checked by pressing the ON PRINT key for 3 seconds The display shows the net total weig...

Страница 13: ...digit by pressing the UNITS key Decrease the flashing digit by pressing the ZERO OFF key Pressing the TARE key or the ON PRINT key will change the position of the flashing digit 10 After entering the...

Страница 14: ...ht value with one digit blinking The pointer for SP1 is lit 2 Use the four directional keys to adjust the displayed value to the desired low weight value Increase the flashing digit by pressing the UN...

Страница 15: ...SP1 light is ON Backlight colors is BLUE If the displayed weight net or gross is more than the High Max value then Digital Output 3 is activated SP3 light is ON Backlight colors is RED If the displaye...

Страница 16: ...ndicator WIRELESS SYSTEMS ONLY TI 500 RFTM 1 batteries have been depleted and need to be replaced WIRELESS SYSTEMS ONLY TI 500 RFTM 2 batteries have been depleted and need to be replaced WIRELESS SYST...

Страница 17: ...ight Operating temperature 4 F to 104 F 20 C to 40 C Internal connection port for optional printer Tilt adjustable bracket included AC Power 90 308 VAC 50 60 Hz DC Power 5 15 VDC OPTIONAL Bluetooth Sp...

Страница 18: ...d cell damaged on platform Internal fault with indicator call Transcell Tech Support Scale turns off on its own The indicator has a power conservation feature set to automatically power off the scale...

Отзывы: