background image

CHAPTER 1:  INTRODUCTION TO THE TC-100 SERIES SETUP MANUAL 

 
 
Your Model TC-100 Series Digital Scale is a complete scale and has been configured and cali-
brate installed for you at the factory. This manual is intended for the dealer or end user who 
wishes to customize the scale’s configuration. 
 
 
The scale's installation and wiring instructions are found in Chapter 2. The scale contains two 
main setup menus: The Setup (“F”) menu, which configures the Scale to your weigh platform and 
the User (“A”) menu, which configures the serial communication port and enables some user op-
tions. Chapter 3 gives an overview and explains how to use the five front panel keys to maneuver 
and save settings in both menus. Chapters 4 and 5 explain the Setup and User Menu options, 
respectively. Chapter 6 covers system calibration. Prior to installing the Scale, please read this 
manual carefully and completely.  Store the manual in a safe and convenient place so it will be 
available if you have questions concerning the setup and operation of the scale. 
 
 

 

Page 1-1 

Содержание TC-100 Series

Страница 1: ...1 0 January 10 2003 2003 Transcell Technology Inc Contents subject to change without notice Transcell Technology Inc 975 Deerfield Parkway Buffalo Grove IL 60089 Tel 847 419 9180 Fax 847 419 1515 E m...

Страница 2: ...1 3 2 3 Notes on the Setup Menu 3 2 3 2 4 Exiting the Setup Menu 3 2 3 3 User A Menu 3 2 Chapter 4 Setup Menu Descriptions and Procedures 4 1 4 1 Setup Menu Descriptions 4 1 4 2 Resetting Factory Def...

Страница 3: ...menu which configures the Scale to your weigh platform and the User A menu which configures the serial communication port and enables some user op tions Chapter 3 gives an overview and explains how t...

Страница 4: ...ed for connection to either a PC or a serial printer It can also be connected to a simplex device such as a remote display COM1 is wired to a physical connector a D SUB9 female Refer to the TC 100 Ope...

Страница 5: ...e scale shows F 1 you are in Setup Menu mode and you may release the 0 key 3 2 2 NAVIGATING IN THE SETUP MENU Use the directional keys shown in Figure 3 1 to move around in the Setup Menu Chart shown...

Страница 6: ...ETUP MENU 1 Detailed descriptions of the setup menu parameters can be found in Chapter 5 of this manual 3 2 4 EXITING THE SETUP MENU 1 Power off the scale by toggling the ON OFF switch 2 Power on the...

Страница 7: ...nit to be used in the calibration process Also the default unit for normal operation 1 primary unit is lb 2 primary unit is in kg 1 2 depends on model F9 Display Divisions Determines the desired weigh...

Страница 8: ...while switching the scale back on You may release that key when the scale displays the corresponding message found in Table 4 1 MODEL CAPACITY GRADUATION KEY MESSAGE TC 100 2 2 lb x 0 0002 lb 1 INIT 2...

Страница 9: ...Page 5 1 CHAPTER 5 USER MENU DESCRIPTIONS AND PROCEDURES 5 1 USER MENU DESCRIPTIONS Please refer to Chapter 5 of the TC 100 Operation Manual...

Страница 10: ...1 While in the Setup mode scroll to F 17 then scroll down once using the 6 key to enter span calibration menu 2 The display will momentarily show C 1 for the span calibration followed by a value with...

Отзывы: