Overview 

Operational Overview 

 

Trango Broadband Wireless — TrangoLINK-10 User Manual Rev. E 3.0

 

page

 2 

 

 

 

 

Figure 2:  Back of Radio (Shows where MAC address can be found)

 

Ethernet and Serial Ports 

At the bottom of the radio are two access ports: a twist-on weatherproof cable port for RJ-45 Ethernet (and PoE), and an 
access cover plug for the RJ-11 serial port.    Behind the access cover plug are three LEDs that provide RF link-status 
information.  These LEDs are discussed later in this text. 
 

 

 

 

Figure 3:  Bottom of Radio 

 

Operational Overview 

TrangoLINK-10 MU is a sophisticated broadband wireless device that provides a host of comprehensive tools and 
functions.  The MU typically resides at the managing end of the network and performs all management functions for the 
associated RU.   
 
In order to establish a wireless link between the MU and the RU, the system administrator must set up the MAC 
address of the RU in the MU.  
 
When power is first applied to a properly installed RU, it will scan all channel/polarization combinations 
searching for an MU.  Once the RU detects the MU it will stop scanning and lock onto the channel of the MU 
and begin transmitting using maximum RF power.  Before the MU can wirelessly connect to the RU, it must 
authenticate the RU by verifying the MAC address and performing a ranging operation to the RU.   
 
Upon successfully authenticating and ranging the RU, the MU will adjust the RF transmit power in the RU 
based on the Target RSSI parameter in the MU.  This process is referred to as “power leveling.”  
 
At this point the MU and RU are “associated” and Ethernet traffic will pass over the wireless link. 

 

The only way to tell MUs and RUs apart is by the 
model number printed on the backside product 
label.  This label also contains the MAC address 
and serial number of the radio.   

Trango Broadband Wireless 

P5830S-MU                         Rev. A 

S/N:    000001421 
MAC:  00 01 DE 00 02 F3 

FCC ID:  NCYM5830SM 
Canada: XXXXXXXXXX 

This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to Part 15 of the FCC Rules. These limits are 

Содержание TrangoLink-10

Страница 1: ...TrangoLINK 10 Point to Point Wireless Ethernet Bridge USER MANUAL June 2007 Revision E 3 0...

Страница 2: ...3 Configuration 8 Essentials to Establish a Wireless Link 8 Master Unit Configuration 8 Settings 9 Master Unit Configuration Screen 9 Remote Unit Configuration Screen 10 Basic Diagnostics 11 Master U...

Страница 3: ...can be found 2 Figure 3 Bottom of Radio 2 Figure 4 Wiring Diagram 3 Figure 5 Pin outs for Serial Cable 7 Figure 6 Mounting Hardware Assembly 19 Figure 7 Alternative Mounting Hardware Assembly 19 Figur...

Страница 4: ...y energy and if not installed and used in accordance with these instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in an...

Страница 5: ...g various antenna configurations Longer ranges are achievable but will result in lower fade margins The TrangoLINK 10 system consists of two types of radios Master Units MU and Remote Units RU The MU...

Страница 6: ...t applied to a properly installed RU it will scan all channel polarization combinations searching for an MU Once the RU detects the MU it will stop scanning and lock onto the channel of the MU and beg...

Страница 7: ...PoE If connecting to a COMPUTER use a Cross Over Ethernet cable from the NET port of the J box to the computer s Ethernet port If connecting to a HUB SWITCH or ROUTER use a Straight Thru cable Plug t...

Страница 8: ...nce for a complete listing of commands and the appropriate Opmode s for each command Note Factory Default Opmode for both MUs and RUs is Off Default Opmode should be changed before radios are deployed...

Страница 9: ...ll pages The top displays the model number of the radio to which you are connected On the bottom of the Navigation Column is the Current Status of the radio including current Opmode active channel rem...

Страница 10: ...et ip address of radio Example C telnet 192 168 100 100 Note All Trango radios are pre configured at the factory with a default IP address of 192 168 100 100 You will be greeted with current hardware...

Страница 11: ...ial type the command logout Type help or for a listing of all CLI commands Type help command for the syntax of a particular command Figure 5 Pin outs for Serial Cable Terminal Settings Changing Passwo...

Страница 12: ...Configure Basic RU Parameters Establish a Wireless Link Evaluate Link Quality The TrangoLINK 10 uses the concept of association to indicate that the MUs and RUs are communicating If all parameters are...

Страница 13: ...ss of the remote unit RU Block Broadcast Packets If this switch setting is selected the MU will not pass broadcast or multicast packets across the link with the exception of ARP and DHCP Auto Powerlev...

Страница 14: ...Channel to match MU 4 Update system setting flash memory by clicking Save and Activate Settings button 5 Click Activate Opmode At this point the RU will begin scanning all channels actively searching...

Страница 15: ...less link RF Link Loopback Test Sends 1600 byte packets to the RU at 50 millisecond intervals over the time specified and reports a bandwidth measure in kbps Ranging RSSI Test Reports the distance of...

Страница 16: ...information screen along with a description of each of the most important changeable parameters as well as related commands for the CLI are shown in the tables below Note When changing settings it is...

Страница 17: ...lnet session the radio will remain in Opmode OFF Configuration page CLI Command set defaultopmode on off System Up Time Time since radio was last rebooted or power cycled Informational Parameter Radio...

Страница 18: ...mbers to actual frequencies of operation The default channels 1 6 are assigned to ISM band Note All channels may be re assigned as desired by the user Default settings allow optimum use of the availab...

Страница 19: ...ode ON or OFF of the radio after reboot power cycle When the parameter is set to ON the radio will progress into Opmode ON 30 seconds after reboot power cycle Note If radio startup is interrupted with...

Страница 20: ...Current channel If MU Autoscan feature is on and if the RU is not associated to an MU it will continue to cycle through all channels until it detects and MU Informational Parameter Broadcast Packet F...

Страница 21: ...ar from sources of interference as possible Site survey Both the MU and RU provide an on board site survey tool This tool will tell you if there is any interference present in the 5 8 GHz band To use...

Страница 22: ...ely important Use of the 5 8 GHz spectrum ISM band will allow maximum co location potential See www trangobroadband com for additional information on channel planning schemes Installation Once the sit...

Страница 23: ...Radio 1 2 10 x 3 Threaded Rod 4 3 10 Keps Nut 8 4 V Bracket 2 5 Mono Pod Mount Not Supplied 1 Figure 6 Mounting Hardware Assembly ITEM NO PART NUMBER QTY 1 Radio 1 2 10 x 3 Threaded Rod 4 3 10 Keps N...

Страница 24: ...io itself is grounded It is important to consider that most Cat 5 cable will deteriorate over time if exposed to the weather especially direct sunlight It is recommended that installers place all Cat...

Страница 25: ...nd to precisely align the RU antenna for maximum signal strength RU Antenna Alignment Procedure 1 Ensure MU is in Opmode ON 2 Connect to the RU from the Ethernet side via the Browser Interface 3 Login...

Страница 26: ...side use the Link Control page to assess the quality of the link Enter a duration time for the RF Link Loopback Speed Test Click the loopback test button The test will execute and report the success...

Страница 27: ...ream 0 kbps ru ipconfig new ip new subnet new gateway ru ping ru powerleveling ru reboot ru speedtest pkt len byte 64 1760 file size MBytes 10 100 ru sysinfo ru testrflink pkt len 64 1760 A complete d...

Страница 28: ...roughputLog Average payload data throughput in Kbits sec transmitted on the Ethernet port over a period of 1 minute mutrafficRfRXAvgThroughputLog Average payload data throughput in Kbits sec received...

Страница 29: ...e to C Program Files SNMPc Network Manager mibfiles 4 Copy autoico txt file to C Program Files SNMPc Network Manager mibfiles 5 Copy trango ico file to C Program Files SNMPc Network Manager bitmaps 6...

Страница 30: ...ters se se help display complete help page except eng se se help command search and display command s help se se ipconfig new ip new subnet mask new gateway assign radio s IP subnet mask and gateway I...

Страница 31: ...rxth ism 90 85 80 75 70 65 specify RF RX Threshold se se default 90 for both band rfrxthreshold same as rfrxth se se rssi display current RX RSSI se save same as updateflash se se save mm same as upda...

Страница 32: ...mage fpgaimage current chscksum new checksum get image from TFTP buffer verify checksum and write to flash memory at main or FPGA image section skip checksum verification se se updateflash systemsetti...

Страница 33: ...eT Network Protocols All IEEE 802 3 802 3u compliant protocols Configuration and Management Telnet SNMP TFTP HTTP Serial Upstream Downstream Throughput Dynamic automatically adjusts to suit demand Phy...

Отзывы: