![Trane TZEMT500AB32MAA Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/trane/tzemt500ab32maa/tzemt500ab32maa_installation-instructions-manual_1150380013.webp)
Gas Furnace - Multistage
Mechanical Settings
Press the
a.
MENU button twice.
Press and hold the two inner buttons for 3 seconds to view
b.
Installer Settings.
Scroll down to
c.
System Settings and press the Select button.
Scroll to
d.
Mechanical Settings (it is the first option), then
press the
Select button.
Scroll down to
e.
2nd Stage Heat.
Press the
f.
+ button to change the setting to Y for Yes.
If your system also has 2nd stage cooling, scroll down to
g.
2nd Stage Cool and Press the + button to change the setting
to
Y for Yes.
Press the
h.
Done button 4 times and go to step 19.
Menu
button
MENU MODE FAN RUN
75
76 H
74 C
11:15 AM
Two inner
buttons
Select
button
Scroll
up
Scroll
down
+
button
Done
Mechanical Settings
Select
Type Heatpump
Fan Type Elec
C/O Type w/Cool
2nd Stage Heat N
18A
13
Electric Furnace
Mechanical Settings
Press the
a.
MENU button twice.
Press and hold the two inner buttons for 3 seconds to view
b.
Installer Settings.
Scroll down to
c.
System Settings and press the Select button.
Scroll to
d.
Mechanical Settings (it is the first option), then
press the
Select button.
Scroll down to
e.
Fan Type.
Press the
f.
+ button to change the setting Electric.
If Single Stage System,
press
Done 4 times and go to step 19.
If Multistage System,
continue with steps “g” through “j”.
Scroll down to
g.
2nd Stage Heat.
Press the
h.
+ button to change the setting to Y for Yes.
If your system also has 2nd stage cooling, scroll down to
i.
2nd Stage Cool and Press the + button to change the setting
to
Y for Yes.
Press the
j.
Done button 4 times and go to step 19.
18B
18C
Heat Pump
Mechanical Settings
Press the
a.
MENU button twice.
Press and hold the two inner buttons for 3 seconds to view
b.
Installer Settings.
Scroll down to
c.
System Settings and press the Select button.
Scroll to
d.
Mechanical Settings (it is the first option), then press
the
Select button.
Scroll to system
e.
Type.
Press the
f.
+ button to change the setting to Heat Pump.
Scroll down to
g.
Fan Type.
Press the
h.
+ button to change the setting Electric.
If Coleman, Rheem, or Rudd brand heat pump, scroll to
i.
C/O
Type and change to With Heat.
If Single Stage System,
press
Done 4 times and go to step 19.
If Multistage System,
continue with steps “j” through “n”.
Scroll down to
j.
2nd Stage Heat.
Press the
k.
+ button to change the setting to Y for Yes.
Scroll down to
l.
2nd Stage Cool.
Press the
m.
+ button to change the setting to Y for Yes.
Press the
n.
Done button 4 times and go to step 19.