15
Performance
Data
SSP-PRC002-EN
Table PD-4 — Gross Cooling Capacities (MBh) TWA200B Heat Pump with TWE200B Air Handler (I-P)
Ambient Temperature (°F)
85
95
105
115
Enter.
Dry
Entering Wet Bulb (°F)
Bulb
61
67
73
61
67
73
61
67
73
61
67
73
CFM
(°F)
Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens.
6000
75
203.1 161.9 223.6 134.6 245.6 90.5
195.3 158.0 215.0 131.1 236.2 87.2 187.1 153.8 206.1 127.5 226.3 83.8 178.5 149.6 196.9 123.8 216.2 80.4
80
204.0 189.2 223.9 154.6 245.5 118.7 196.4 185.3 215.4 150.9 236.2 115.1 188.5 181.3 206.5 147.1 226.5 111.5 180.4 177.1 197.1 142.8 216.4 107.8
85
209.2 209.2 224.1 181.3 245.8 146.0 202.6 202.6 215.6 177.5 236.5 142.5 195.6 195.6 206.8 173.4 226.8 138.8 188.4 188.4 197.6 169.3 216.8 135.1
90
219.3 219.3 225.1 208.3 246.0 173.3 212.6 212.6 216.9 204.5 236.8 169.7 205.4 205.4 208.4 200.6 226.9 165.4 198.1 198.1 199.8 196.6 217.0 161.4
6675
75
206.9 169.4 227.5 131.5 249.5 92.2
198.8 165.3 218.7 127.8 239.7 88.9 190.3 161.2 209.5 124.0 229.7 85.4 181.6 156.9 200.0 120.1 219.2 81.6
80
208.4 199.4 227.8 161.7 249.5 122.5 200.6 195.4 218.8 157.5 239.8 119.0 192.7 191.4 209.7 153.5 229.8 115.3 184.1 184.1 200.3 149.3 219.5 111.5
85
215.7 215.7 228.0 190.5 249.7 152.4 208.8 208.8 219.3 186.6 240.1 148.8 201.6 201.6 210.3 182.5 230.2 145.1 194.0 194.0 201.0 178.4 219.9 141.3
90
226.3 226.3 229.8 220.2 249.8 181.5 219.2 219.2 221.5 216.4 240.3 177.7 211.7 211.7 213.0 212.4 230.4 173.8 204.0 204.0 203.9 203.9 220.1 169.7
7350
75
210.0 176.5 230.7 135.8 252.6 93.8
201.8 172.4 221.7 132.1 242.7 90.2 193.1 168.2 212.3 128.3 232.3 86.5 184.3 163.9 202.6 124.4 221.6 82.8
80
212.3 209.2 230.9 167.8 252.7 126.2 203.5 203.5 221.9 163.9 242.8 122.6 196.3 196.3 212.6 159.8 232.6 118.9 188.6 188.6 202.9 155.6 222.0 115.1
85
221.4 221.4 231.4 199.3 253.0 158.4 214.2 214.2 222.6 195.4 243.2 154.8 206.7 206.7 213.4 191.3 233.0 151.1 198.9 198.9 204.0 187.2 222.4 147.3
90
232.3 232.3 234.1 231.7 253.1 189.6 225.0 225.0 224.8 224.8 243.4 185.8 217.2 217.2 217.1 217.1 233.2 181.8 209.2 209.2 209.1 209.1 222.7 177.7
8025
75
212.7 183.3 233.5 140.0 255.3 95.0
204.4 179.2 224.2 136.2 245.1 91.4 195.6 175.0 214.6 132.4 234.6 87.7 186.7 170.6 204.8 128.4 223.7 83.9
80
215.3 215.3 233.7 174.0 255.5 129.7 208.1 208.1 224.5 170.0 245.4 126.1 200.5 200.5 215.0 165.9 234.9 122.4 192.7 192.7 205.2 161.7 224.1 118.6
85
226.5 226.5 234.4 207.9 255.8 164.2 219.0 219.0 225.5 203.9 245.7 160.6 211.3 211.3 216.2 199.8 235.1 156.3 203.2 203.2 206.6 195.7 224.4 152.2
90
237.7 237.7 237.6 237.6 256.0 197.4 230.1 230.1 230.0 230.0 246.0 193.5 222.1 222.1 222.0 222.0 235.6 189.5 213.7 213.7 213.6 213.6 224.9 185.4
Note: All temperatures are in degrees Fahrenheit. Airflow is in cfm.
Table PD-4 — Gross Cooling Capacities (kW) TWA200B Heat Pump with TWE200B Air Handler (SI)
Ambient Temperature (°C)
29.4
35.0
40.6
46.1
Enter.
Dry
Entering Wet Bulb (°C)
Bulb
16.1
19.4
22.8
16.1
19.4
22.8
16.1
19.4
22.8
16.1
19.4
22.8
m
3
/h
(°C)
Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens.
10194
24
59.5
47.4 65.5 39.4 71.9 26.5
57.2
46.3 63.0 38.4 69.2 25.5 54.8 45.0 60.3 37.3 66.3 24.5 52.3 43.8 57.6 36.2 63.3 23.5
27
59.7
55.4 65.6 45.3 71.9 34.7
57.5
54.3 63.1 44.2 69.2 33.7 55.2 53.1 60.5 43.1 66.3 32.6 52.8 51.9
57.7 41.8 63.4 31.6
29
61.2
61.2 65.6 53.1 72.0 42.8
59.3
59.3 63.1 52.0 69.2 41.7 57.3
57.3 60.5 50.8 66.4 40.6 55.2 55.2 57.9 49.6 63.5 39.5
32
64.2
64.2 65.9 61.0 72.0 50.7
62.2
62.2 63.5 59.9 69.3 49.7 60.2 60.2 61.0 58.7 66.4 48.4 58.0 58.0 58.5 57.6 63.5 47.3
11341
24
60.6
49.6 66.6 38.5 73.0 27.0
58.2
48.4 64.0 37.4 70.2 26.0 55.7 47.2 61.3 36.3 67.2 25.0 53.2 45.9 58.6 35.2 64.2 23.9
27
61.0
58.4 66.7 47.3 73.0 35.9
58.7
57.2 64.1 46.1 70.2 34.8 56.4 56.0 61.4 44.9 67.3 33.8 53.9 53.9 58.6 43.7 64.3 32.7
29
63.2
63.2 66.8 55.8 73.1 44.6
61.1
61.1 64.2 54.6 70.3 43.6 59.0 59.0 61.6 53.4 67.4 42.5 56.8 56.8 58.9 52.2 64.4 41.4
32
66.2
66.2 67.3 64.5 73.1 53.1
64.2
64.2 64.8 63.4 70.4 52.0 62.0 62.0 62.4 62.2 67.5 50.9 59.7 59.7 59.7 59.7 64.5 49.7
12488
24
61.5
51.7 67.6 39.8 74.0 27.5
59.1
50.5 64.9 38.7 71.1 26.4 56.5 49.2 62.2 37.6 68.0 25.3 54.0 48.0 59.3 36.4 64.9 24.2
27
62.2
61.2 67.6 49.1 74.0 36.9
59.6
59.6 65.0 48.0 71.1 35.9 57.5
57.5 62.2 46.8 68.1 34.8 55.2 55.2 59.4 45.6 65.0 33.7
29
64.8
64.8 67.8 58.4 74.1 46.4
62.7
62.7 65.2 57.2 71.2 45.3 60.5 60.5 62.5 56.0 68.2 44.2 58.2 58.2 59.7 54.8 65.1 43.1
32
68.0
68.0 68.5 67.8 74.1 55.5
65.9
65.9 65.8 65.8 71.3 54.4 63.6 63.6 63.6 63.6 68.3 53.2 61.3 61.3 61.2 61.2 65.2 52.0
13634
24
62.3
53.7 68.4 41.0 74.8 27.8
59.8
52.5 65.7 39.9 71.8 26.8 57.3 51.2 62.8 38.8 68.7 25.7 54.7 50.0 60.0 37.6 65.5 24.6
27
63.0
63.0 68.4 51.0 74.8 38.0
60.9
60.9 65.7 49.8 71.8 36.9 58.7 58.7 63.0 48.6 68.8 35.8 56.4 56.4 60.1 47.3 65.6 34.7
29
66.3
66.3 68.6 60.9 74.9 48.1
64.1
64.1 66.0 59.7 72.0 47.0 61.9 61.9 63.3 58.5 68.8 45.8 59.5 59.5 60.5 57.3 65.7 44.6
32
69.6
69.6 69.6 69.6 74.9 57.8
67.4
67.4
67.3
67.3 72.0 56.7 65.0 65.0 65.0 65.0 69.0 55.5 62.6 62.6 62.6 62.6 65.9 54.3
Note: All temperatures are in degrees Celsius. Airflow is in liters per second.