background image

WALL-MOUNT AIR HANDLERS

2-3TON COOLING/HEAT PUMP

TMM5B0A24M21SAA 

TMM5B0B30M21SAA 

TMM5B0B36M31SAA

ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

Important: This Document is customer property and is to remain with this unit.

Installer’s Guide

Section 1. Features

1.1  Standard Features

1.2  Optional Accessories

5, 7.5 and 10 kW SINGLE PHASE ELECTRIC

HEATERS

- Circuit breakers are standard on all single

phase 5, 7.5 and 10 kW heaters.

The TMM5B series wall mount air handler is designed for installation in a closet, utility room, alcove 
and can be wall mounted. These versatile units are applicable to air conditioning and heat pump 
applications. Field installed electric resistance heaters are available.

All aluminum coil.

Blower and coil slide out easily for maintenance.

Factory-sealed cabinet certified to achieve 2% or

less air leakage rate at 1.0 inch water column.

Front or bottom return air.

Painted finish on galvanized steel.

Sturdy polycarbonate drain pans.

- Air handler has factory installed drain pans and

is shipped for upflow applications only.

208/230 VAC operation.

Multi-speed direct drive blower constant torque

ECM motor with fan-off time delay programming.

Factory installed R-410A thermal expansion

valve.

Stud or wall mounting installation.

Fully insulated cabinet.

3/4'' NPT primary and secondary drains.

AHRI certifird and ETL listed.

18-GF13D1-1A-EN

Содержание TMM5B0A24M21SAA

Страница 1: ...versatile units are applicable to air conditioning and heat pump applications Field installed electric resistance heaters are available All aluminum coil Blower and coil slide out easily for maintenan...

Страница 2: ...state electrical code on requirements for grounding Failure to follow this warning could result in property damage serious personal injury or death HAZARDOUS VAPORS Do not install an air handler with...

Страница 3: ...ns adhesives cleaning compounds and cement creates a corrosive condition which may cause rapid deterioration of the cabinet and internal components CAUTION SAFETY HAZARD Sharp Edge Hazard Be careful o...

Страница 4: ...the air handler above the wall mounting bracket and attach the unit to the installed bracket Reference Figure 3 1 4 Install the additional bottom plate for extra support for this type mounting see fi...

Страница 5: ...dential Winter and Summer Air Conditioning and Equipment Selection Latest editions are available from ACCA Air Conditioning Contractors of America 1513 16th Street N W Washington D C 20036 If duct sys...

Страница 6: ...ze the fan on a demand for heating or cooling Install the thermostat on an inside wall away from drafts lights or other heat sources in a location that has sufficient air circulation from other rooms...

Страница 7: ...uspension if used is secure and there are no tools or loose debris in around or on top of the unit 2 Properly insulate suction lines and fittings 3 Properly secure and isolate all refrigerant lines 4...

Страница 8: ...COMPONENT ARRANGEMENT FM NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND NE CONVIENT PAS AUXINSTALLATIONS DE PLUS DE 150V ALA TERRE CAUTION ATTENTION TMM5B0A24M21SAA TMM5B0B36M31SAA Fig 4 1 8...

Страница 9: ...COMPONENT ARRANGEMENT FM NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND NE CONVIENT PAS AUXINSTALLATIONS DE PLUS DE 150V ALA TERRE CAUTION ATTENTION Fig 4 2 TMM5B0B30M21SAA 9...

Страница 10: ...24 36 24 36 24 36 10 Circuit Breaker Minimum CFM MODEL 1 2 3 575 600 625 575 600 625 700 725 750 10 TMM5B0A24M21SAA TMM5B0B30M21SAA TMM5B0B36M31SAA Section 5 Heater Pressure Drop Table Use For All TMM...

Страница 11: ...n dry coil at 230V with no electric heat no filter For 24 30 and 36 sizes airflow at 208V is approximately the same as 230V because the mult tap ECM motor is a constant torque motor The torque doesn t...

Страница 12: ...ection 3 4 female pipe thread NPT Primary drain conncetion 3 4 female pipe thread NPT Front return shown Units may also be installed as bottom return See the applications section for more detail NOTE...

Страница 13: ...ww trane com www americanstandardair com The manufacturer has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice Tran...