ELECTRONIC HEAT PUMP THERMOSTAT

Pub. No. 11-HD28D2-1

Fig. 1. Typical location of thermostat.

5 FEET

[1.5 METERS]

YES

NO

NO

NO

M10106

Fig. 2. Mounting the wallplate.

WIRES 
THROUGH WALL

WALL

MOUNTING 
HOLES

MOUNTING 
SCREWS

M6530

WALL
ANCHORS
(2)

Wallplate Installation

Mount tthermostat horizontally on the wall or on a 2 in. x 4
in. wiring box.

1. Position and level the wallplate (for appearance

only). The thermostat functions properly even when
not level.

2. Use a pencil to mark the mounting holes. See

Fig. 2.

3. Remove the wallplate from the wall and drill two

3/16 inch holes in the wall (if drywall) as marked. For
firmer material such as plaster or wood, drill two
7/32 inch holes. Gently tap anchors (provided) into
the drilled holes until flush with the wall.

4. Position the wallplate over the holes, pulling wires

through the wiring opening.

5. Loosely insert the mounting screws into the holes.
6. Tighten mounting screws.

Содержание TAYSTAT 575

Страница 1: ...age the product or cause a hazardous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After completing installation use these instructions to check out the product operation CAUTION Electrical Shock or Equipment Damage Hazard Can shock individuals or sh...

Страница 2: ...nd level the wallplate for appearance only The thermostat functions properly even when not level 2 Use a pencil to mark the mounting holes See Fig 2 3 Remove the wallplate from the wall and drill two 3 16 inch holes in the wall if drywall as marked For firmer material such as plaster or wood drill two 7 32 inch holes Gently tap anchors provided into the drilled holes until flush with the wall 4 Po...

Страница 3: ... 2 FEATURE NOT AVAILABLE ON ALL SYSTEMS 3 USE OUTDOOR TEMPERATURE SENSOR TAYSENS200A AND CONFIGURE INSTALLER SETUP NUMBERS 24 TO 1 3 AUX HEAT RELAY BLUE YELLOW BROWN GREEN ORANGE BLACK WHITE RED Fig 3 Typical hookup in heat pump system with emergency heat relay CAUTION Electrical Shock or Equipment Damage Hazard Can shock individuals or short equipment circuitry Disconnect power supply before inst...

Страница 4: ...ive in mild weather conditions and during nighttime operation low load The effect of Cooling Droop on indoor temperature operation typically lowers the indoor temperature by up to one or two degrees If the cooling droop is not desired it can be disabled Comfort R Comfort R helps achieve comfort with a lower humidity level When enabled selected in installer setup the thermostat calculates a fan del...

Страница 5: ... three seconds The display scrolls the numbers backward to get to the normal display The Installer Setup is automatically exited if no key presses are made for five minutes Fig 8 Display of all LCD segments Fig 9 Display of installer setup and setting NOTE Only configurable numbers are shown Em HeatOffCool Auto Only Heat Cool OnAuto System Fan Room Outdoor Em Ht Temporary Setting Wait Humid Aux Ht...

Страница 6: ...No outdoor temperature displays 01 Outdoor temperature is displayed Needs a TAYSENS100A Outdoor Sensor Comfort R Enable 28 00 No fan delay 01 or 02 01 30 seconds maximum delay 02 15 seconds maximum delay Minimum deadband between heating and cooling in auto changeover mode 30 04 Heating and cooling setpoints can be set no closer than 4 F 2 C 03 thru 10 Heating and cooling setpoints can be set no cl...

Страница 7: ...ipment can be turned on and off 30 39 Cooling equipment can be turned on and off 40 49 Fan equipment can be turned on and off 60 69 System key or system switch position test 70 79 Thermostat information displayed including date code and software versions Table 2 Thermostat Installer Setup Options Continued Installer Setup Number Factory Setting Other Choices Press or key to change Select Display D...

Страница 8: ...ge one cool and system fan come on 32 Stage two cool comes on Stage one cool and system fan remain on 31 Stage two cool turns off 30 Stage one cool and system fan turn off Fan Equipment System Test i 40 Change from cooling to fan equipment system test 41 Fan comes on 40 Fan turns off Key Operation System Test IMPORTANT Test Numbers will be displayed only when the system is configured for the selec...

Страница 9: ...an accurate thermometer 1 F 0 5 C measure the temperature at the sensor location allowing time for the thermometer to stabilize before reading Match the thermometer reading to the outdoor temperature display at the thermostat M6791 M4864 M4865 M4866 Thermostat Information 1 Press the Information i key to access the thermo stat information 2 Press the increase key to display the production date cod...

Страница 10: ...igure the display Bad thermostat location Relocate the thermostat Temperature settings will not change Example Cannot set the The upper or lower temperature limits were reached Check the temperature setpoints Heating limits are 55 to 85 F 13 to 29 C Cooling limits are 65 to 99 F 18 to 37 C heating higher or the cooling lower The setpoint temperature range stops were configured Check Installer Setu...

Страница 11: ...nnections If 24 Vac is present proceed with troubleshooting Thermostat minimum off time is activated Wait up to five minutes for the system to respond Enter Installer Setup mode number 33 Reconfigure minimum off time if required System selection is not set to Cool Set system selection to Cool System On indicator is lit but no heat is being delivered Heating equipment is not operating Verify operat...

Страница 12: ...0 CUSTOMERASSISTANCE If after reading this guide you have any questions concerning the operation of your thermostat please call the Thermostat Customer Assistance Helpline at 1 877 880 3381 For service contact your local heating and cooling contractor Pub No 11 HD28D2 1 ...