background image

486678

Contents

While  the  company  undertakes  responsibility  to  supply  only  the  compressor  free  of  cost  during  warranty  period,  cost  of  labour, 

transportation and other incidental expenditures shall be borne by the customer after the lapse of first year Product warranty.
In areas where voltage fluc/-10% of rated or usable voltage, customer is advised to use a branded voltage stabilizer which steps 

up or down the incoming voltage to give an output of 0V. For any fluctuation beyond the reasonable specified limit, the company 

shall not be responsible and this warranty shall immediately stand terminated.
Earthing provision is necessary for safety. Improper domestic wiring leading to hazards such as shock or fire is not covered under this 

warranty.
While the Company will make every effort to carry out the repairs at the earliest, it however is made expressly clear that the company is 

under no obligation to do so in a specified period of time.
Any special, indirect or consequential property or commercial damage of any nature whatsoever is not covered under this warranty.
The warranty is issued at Bangalore, and Courts at Bangalore shall have exclusive jurisdiction over matters covered or flowing from this 

warranty.

Warranty is null and void in the following cases:

Warranty

 

card

 

is

 

not

 

duly

 

filled

 

and

 

mailed

 

back

 

to

 

the

 

service

 

centre

 

for

 

registering

 

the

 

Product

 

within

 

three

 

months

 

of

 

purchase.

Complete

 

warranty

 

card

 

is

 

not

 

presented

 

to

 

authorized

 

personnel

 

at

 

the

 

time

 

of

 

repair.

Product

 

is

 

not

 

used

 

according

 

to

 

the

 

instructions

 

given

 

in

 

the

 

user

 

manual.

Original

 

serial

 

number

 

is

 

removed/tampered

 

with.

Modification

 

or

 

alteration

 

of

 

any

 

nature

 

whatsoever

 

is

 

made

 

in

 

the

 

electrical

 

circuit/physical

 

construction

 

of/to

 

the

 

Product.

Installation/repair

 

work

 

carried

 

out

 

by

 

person/agency

 

other

 

than

 

authorized

 

agency.

Site

 

conditions

 

that

 

do

 

not

 

confirm

 

to

 

the

 

recommended

 

operating

 

conditions

 

of

 

machine.

14.

15.

16.

17.

18.
1.

1.
.
.
4.
5.
6.
7.

For any product related assistance, please call on Toll free number: 1800 102 9986.

The 1 year warranty is applicable to all parts except for Plastic & Rubber parts.

0.

Содержание SPLIT AC

Страница 1: ...OWNER S GUIDE AIR CONDITIONER INTERACTIVE TRANE SPLIT AC SPLIT AC WITH REMOTE INTERACTIVE...

Страница 2: ...ing TRANE Interactive AC is one such product The TRANE Interactive AC assesses manages and gives feedback on your in home climate The ultra slim design brings together simplicity and elegance that com...

Страница 3: ...2 Functions 14 2 4 2 1 Trane Mode 14 2 4 2 2 Cool Mode 15 2 4 2 3 Dry Mode 15 2 4 2 4 Fan Mode 15 2 4 2 5 Sleep Mode 15 2 4 2 6 Turbo Mode 16 2 4 2 7 Fan speed 16 2 4 2 8 Night latch Mode Only for uni...

Страница 4: ...ce contract with a TRANE service company Do not operate before reading manual s supplied with this product Cautions as applicable are shown in this manual Personal safety and proper operation of this...

Страница 5: ...property damage Obey the following points to prevent electrical shock or fire Don ts Do not remove power plug while the unit is in operation It can cause an electrical shock or fire Do not operate th...

Страница 6: ...cause injury Do not spray or wash the unit with water It can cause electrical shock and or malfunction of unit Do not splash water on the unit It can cause an electrical shock and or malfunction Do no...

Страница 7: ...ry Do s Make sure that all power supply connections are tight Check whether electrical grounding earth is complete If not done it can cause electrical shock or fire Turn off the power supply and pull...

Страница 8: ...t capacity Incorrect wire can cause breakdown or fire Turn off the power supply If you detect burning smell or smoke turn off power supply and contact customer care centre immediately Don ts Do not tr...

Страница 9: ...e water at a temperature above 45 C to clean it can deform or discolour front panel Do not dry filters near fire It can ignite or deform them Do not drop or throw remote control It can cause malfuncti...

Страница 10: ...g pipe 9 Connecting cable 10 Sensor cable 11 Stop valve Outdoor unit Outdoor unit 1 Front panel 2 Air inlet 3 Air filter 4 Air outlet 5 Horizontal air flow grille 6 LED display 7 Remote control Indoor...

Страница 11: ...he following default conditions MODE COOL FAN SPEED MEDIUM SWING AUTO SET TEMP 24 C Lower the front panel to its initial position Manual control button Figure 3 Use object not more than 5mm in diamete...

Страница 12: ...NE mode active GREEN GREEN TRANE mode active Error on PCB GREEN GREEN and RED Blinks alternately Button press on remote GREEN blink once No change Sound Indication Unit status Buzzer Unit powered ON i...

Страница 13: ...crease Temperature Mode Adjustment Energy Efficiency Meter Power ON OFF TRANE Mode Sleep Turbo Mode Figure 6 Symbol Button Function Display Description Fan speed adjustment Air flow rate adjustment Sh...

Страница 14: ...ows current room temperature NA Not Applicable 2 4 1 Range of Operation 2 4 1 1 Lock and Indoor Unit range Range Indoor Range Outdoor without any obstacles 15 meter 1000 meter 2 4 1 2 Remote and Indoo...

Страница 15: ...ress mode to select dry mode see DRY shown on display Refer Figure 10 In dry mode default set temperature is 25 C Set temperature and fan speed cannot be changed Unit will operate at low fan speed for...

Страница 16: ...activate or deactivate night latch mode on lock Night latch will show on remote display after it starts approximately 30 seconds for display to update Night latch mode helps user to prevent access to...

Страница 17: ...will glow in red 2 4 3 Replacement of Batteries Do not use combination of old and new batteries Life of battery is more than six months in normal usage To prevent batteries from leakage of electrolyte...

Страница 18: ...ld the front panel at its place after lifting it Filter Handle 2 Hold the air filter handle and lift slightly to release it from holder pull downwards to remove air filter from indoor unit 3 Clean air...

Страница 19: ...r dirt the performance of the unit will be affected with higher operation noise and power consumption Air filter screen should be cleaned regularly Preparation before season of use 1 Be sure that noth...

Страница 20: ...uickly by cold air flow which looks like fog Creaking noise during start or stop Deformation of plastic because of temperature change Unit does not operate Check electrical system connections cords an...

Страница 21: ...tact service technician 0x05 OUTDOOR TEMP SENSOR ERROR Error 05 outdoor temp sensor failure contact service technician Operates indoor unit and outdoor unit as per user setting If TRANE mode is activa...

Страница 22: ...it operates as per previous settings Contact service technician AC switched OFF main power OFF SET POINT TEMP Infrared activated No network found Switch ON main power check the plug Lock with AC Lock...

Страница 23: ...tion with deputing of service personnel technicians towards to and fro travel conveyance and other incidentals etc together referred to as Transportation and Handling Expenses shall be borne by the Pu...

Страница 24: ...e Any special indirect or consequential property or commercial damage of any nature whatsoever is not covered under this warranty The warranty is issued at Bangalore and Courts at Bangalore shall have...

Страница 25: ...Corporate Office Plot No 35 KIADB Industrial Area Bidadi Bangalore 562109 www traneindia com For more information call on 1800 102 9986 or write to care trane com 48626782 Edition 1 June 2012...

Отзывы: