System Precautions

Safety Precautions

WARNING

CAUTION

• 

To prevent injury to the user or other people and property
damage, the following instructions must be followed.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to
property.

Incorrect operation due to ingnoring of instructions may
cause harm or damage. The seriousness is classified be
the following indications.

• 

WARNING

WARNING

CAUTION

CAUTION

• 

After reading this manual, be sure to keep it together with
the Owner Manual in a handy place on the customer’s site.

 

Do not install the unit by yourself (customer)

Install the unit securely in a place which can bear the
weight of the unit.

Incomplete installation could cause injury due to fire,
electric shock, the unit falling or leakage of water. Consult
the dealer from whom you purchased the unit or special
installer.

If the electrical cover in the indoor unit and/or the service
panel in the outdoor unit are not attached securely, it could
result in a fire or an electric shock due to dust water, etc.

When installed in an insufficient strong place, the unit
could fall causing injury.

It could cause a fire or an electric shock due to defective
contact, defective insulation, exceeding the permissible
current, etc.

Incomplete connecting and fixing could cause fire.

Attach the electrical cover to the indoor unit and the
service panel to the outdoor unit securely.

 

• 

Locations where there may be a leakage of combustible gases.

• 

The place is filled with oil.

• 

Beachfront location.

• 

The place that contain sulfuric acid, such as hot springs.

• 

The place where high frequency devices or wireless devices
are used.

 

 

Perform earthing.

Do not connect the earth wire to a gas pipe, water pipe,
lightning rod or telephone earth wire. Defective earthing
could cause an electric shock.

 

Be sure to use the part provided or specified parts for
the installation work.

The use of defective parts could cause an injury due to a
fire, an electric shock, the unit falling, leakage of water, etc.

 

Be sure to cut off the main power in case of setting up
the indoor electronic control P.C. board or wiring works.

It could cause an electri shock.

Any presence of foreign substance such as air can cause
abnormal pressure rise or an explosion.

 

The appliance shall be installed in accordance with
national wiring regulations.

 

Do not install the unit in a place where an inflammable
gas leaks.

If gas leak and accumulate in the area surrounding the unit,
it could cause an explosion.

 

 

 

Fasten a flare nut with a torque wrench as specified in
this manual.

 

 

If gas leak and accumulate in the area surrounding the unit,
it could cause an explosion.

 

 

Install a earth leakage breaker depending on the install-
ation place (Where it is humid).

Perform the drainage/piping work securely according
to the installation manual.

If a earth leakage breaker is not installed, it could cause an
electric shock.

 

   

 

Avoid to installing in places that may cause problems to unit.

If there is a defect in the drainage/piping work, water could
drop from the unit and household goods could be wet and
damaged.

 

 

When installing or relocating the unit, make sure that no
substance other than the specified refrigerant (R410A)
enters the refrigerant circuit.

 

 

Check that the refrigerant gas due not leak after install-
ation has completed.

 

Do not use intermediate connection of the power cord
or the extension cord and do not connect many 
devices to one AC outlet.

If refrigerant gas leaks indoors, and comes into contact
with the fire of a fan heater, space heater, stove, etc..
harmful substances will be generated.

Perform the installation securely referring to the install-
ation manual.

 

Incomplete installation could cause a personal injury
due to fire, electric shock, the unit falling or leakage of
water

Perform electrical work according to the installation
manual and be sure to use an exclusive circuit.

 

If the capacity of the power circuit is insufficient or there is
insufficient electrical work, it could result in a fire or an
electric shock.

 

Use the specified wires to connect the indoor and
outdoor units securely and attach the wires firmly to
the terminal block connecting sections so the stress
of the wires is not applied to the sections.

Содержание RAUT 250

Страница 1: ...n be hazardous and requires specific knowledge and training Improperly installed adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equi...

Страница 2: ...No 11 Minor Major Design Sequence Comp Motor A Modular RAUT Design Digit No 12 Factory Installed 0 No Option A Corrosion Resistant Coated Fin Blue Fin B Hydrophobic Coating Fin C Copper Fin and Coppe...

Страница 3: ...Contents Model Nomenclature System Precaution General Information General Data Installation Operation Maintenance Maintenance Compressor Trouble Analysis Dimensional Data Electrical Wiring 2 4 5 6 7 1...

Страница 4: ...ing leakage of water etc Be sure to cut off the main power in case of setting up the indoor electronic control P C board or wiring works It could cause an electri shock Any presence of foreign substan...

Страница 5: ...mail Notify the local Trane Sales Office Concealed damage must be reported within 15 days delivery Check the unit nameplate to confirm that the proper unit was shipped Available power supply must be c...

Страница 6: ...00 26 100 29 000 49 500 29 000 49 500 Vendor Motor Type 710W 710W 900W 1800W 1800W Qty 2 2 2 2 2 Speed RPM 920 920 920 720 720 V ph Hz 380 3 50 380 3 50 380 3 50 380 3 50 380 3 50 RLA LRA each A 3 22...

Страница 7: ...le of handling the weight of the unit Table 1 Clearances Provide sufficient clearance around the unit for performance of service and maintenance Caution unit operation is a function of the air tempera...

Страница 8: ...t and dry nitrogen for leak testing a violent explosion may result 3 Always use a pressure regulator valves and gauges to control drum and line pressures when pressure testing the system Excessive pre...

Страница 9: ...ety 2 Use copper conductors only for installation wiring Unit terminals are not designed to accept other type of wiring The use of aluminium wire may cause galvanic corrosion and or overheating at the...

Страница 10: ...er full load in the compressor oil level sight glass The unit was charged with the proper amount of oil before shipping Under normal operation compressor oil is always expected to return to compressor...

Страница 11: ...e 3B EXPANSION VALVE CAPILLARY TUBES SIGHT GLASS STRAINER LIQUID LINE FROM RECEIVER EXPANSION VALVE SOLENOID LIQUID VALVE EXPANSION VALVE EXPANSION VALVE THERMAL BULBS EXPANSION VALVE EQUALIZER LINES...

Страница 12: ...recommended procedures The following procedures should be carried out by a qualified service technician as part of a maintenance contract The first and last visit will include the seasonal shut down...

Страница 13: ...ction filter is required install it a minimum of 18 upstream of the compressor manifold piping See Figure 4 Caution Altering the original manifold piping may cause oil compressor failure This sequence...

Страница 14: ...line but not on motor side or fuse Voltmeter does not read proper voltage Motor starter holding coil is not energized Compressor will not operate Open contact on high pressure switch Discharge pressu...

Страница 15: ...obable cause Insufficient oil charge Clogged filter drier Liquid flooding back to compressor Recommended action All oil Replace Readjust superheat setting and verify correct bulb mounting F Compressor...

Страница 16: ...Expansion valve opens too far a Adjust superheat and check flood back to compressor bulb attachment b Expansion valve stuck in open b Repair or replace position L Discharge pressure too high Problems...

Страница 17: ...00 1693 0 222 2 208 0 67 4 146 7 SUCTION CONNECTION 1 5 8 1786 0 LIQUID CONNECTION 5 8 99 5 1588 0 99 5 RECOMMANDED CLEARANCE 1070 821 0 RECOMMANDED CLEARANCE 1524 RECOMMANDED CLEARANCE 1524 RECOMMAND...

Страница 18: ...273 0 273 0 2206 0 1156 0 2380 3 RECOMMANDED CLEARANCE 1070 RECOMMANDED CLEARANCE 1524 464 0 183 0 578 0 297 1 128 0 SUCTION CONNECTION SIZE 1 5 8 LIQUID CONNECTION SIZE 5 8 RECOMMANDED CLEARANCE 152...

Страница 19: ...RAUT IOM R410A 19 Electrical Wiring RAUT250 400 Micro P 1 2...

Страница 20: ...20 RAUT IOM R410A Electrical Wiring RAUT250 400 Micro P 2 2...

Страница 21: ...RAUT IOM R410A 21 Electrical Wiring RAUT500 600 Micro P 1 2...

Страница 22: ...22 RAUT IOM R410A Electrical Wiring RAUT500 600 Micro P 2 2...

Страница 23: ...RAUT IOM R410A 23 Electrical Wiring RAUT250 400 with Carel pCO5 1 2...

Страница 24: ...t 1 ID10 J7 2 Low Pressure Switch Circuit 2 ID11 J7 3 High Pressure Switch Circuit 2 ID12 J7 4 Compressor 1 Overload Circuit 2 IDC9 J7 5 Common DI 9 12 ID13h J8 1 Not used ID13 J8 2 Compressor 2 Overl...

Страница 25: ...RAUT IOM R410A 25 Electrical Wiring RAUT500 600 with Carel pCO5 1 2...

Страница 26: ...t 1 ID10 J7 2 Low Pressure Switch Circuit 2 ID11 J7 3 High Pressure Switch Circuit 2 ID12 J7 4 Compressor 1 Overload Circuit 2 IDC9 J7 5 Common DI 9 12 ID13h J8 1 Not used ID13 J8 2 Compressor 2 Overl...

Страница 27: ...RAUT IOM R410A 27 Note...

Страница 28: ...ations without notice We are committed to using environmentally conscious print practices Trane by Trane Technologies NYSE TT a global climate innovator creates comfortable energy efficient indoor env...

Отзывы: