PRGD-SVX01F-EN
25
Maintenance
Maintenance requirements for an EarthWise™ purge
system with Tracer® AdaptiView™ control are
described in this section. To ensure efficient and
reliable purge operation, perform all inspections and
procedures at the prescribed intervals. Keep records of
inspection results to establish proper service intervals.
Document changes that occur in purge activity that
could provide information about chiller performance.
W
WA
AR
RN
NIIN
NG
G
R
Re
effrriig
ge
erra
an
ntt u
un
nd
de
err H
Hiig
gh
h P
Prre
essssu
urre
e!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w iin
nssttrru
uccttiio
on
nss b
be
ello
ow
w cco
ou
ulld
d rre
essu
ulltt iin
n
a
an
n e
ex
xp
pllo
ossiio
on
n w
wh
hiicch
h cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr
sse
erriio
ou
uss iin
njju
urry
y o
orr e
eq
qu
uiip
pm
me
en
ntt d
da
am
ma
ag
ge
e..
S
Sy
ysstte
em
m cco
on
ntta
aiin
nss o
oiill a
an
nd
d rre
effrriig
ge
erra
an
ntt u
un
nd
de
err h
hiig
gh
h
p
prre
essssu
urre
e.. R
Re
ecco
ov
ve
err rre
effrriig
ge
erra
an
ntt tto
o rre
elliie
ev
ve
e p
prre
essssu
urre
e
b
be
effo
orre
e o
op
pe
en
niin
ng
g tth
he
e ssy
ysstte
em
m.. S
Se
ee
e u
un
niitt n
na
am
me
ep
plla
atte
e ffo
orr
rre
effrriig
ge
erra
an
ntt tty
yp
pe
e.. D
Do
o n
no
ott u
usse
e n
no
on
n--a
ap
pp
prro
ov
ve
ed
d
rre
effrriig
ge
erra
an
nttss,, rre
effrriig
ge
erra
an
ntt ssu
ub
bssttiittu
utte
ess,, o
orr rre
effrriig
ge
erra
an
ntt
a
ad
dd
diittiiv
ve
ess..
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err
cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d.. V
Ve
erriiffy
y tth
ha
att n
no
o
p
po
ow
we
err iiss p
prre
esse
en
ntt w
wiitth
h a
a v
vo
ollttm
me
ette
err..
W
WA
AR
RN
NIIN
NG
G
H
Ho
ott S
Su
urrffa
acce
e!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w iin
nssttrru
uccttiio
on
nss b
be
ello
ow
w cco
ou
ulld
d rre
essu
ulltt iin
n
sse
ev
ve
erre
e b
bu
urrn
nss..
S
Su
urrffa
acce
e tte
em
mp
pe
erra
attu
urre
ess m
ma
ay
y e
ex
xcce
ee
ed
d 3
30
00
0°°F
F ((1
15
50
0°°C
C))..
T
To
o a
av
vo
oiid
d p
po
ossssiib
blle
e sskkiin
n b
bu
urrn
nss,, sstta
ay
y cclle
ea
arr o
off tth
he
esse
e
ssu
urrffa
acce
ess.. IIff p
po
ossssiib
blle
e,, a
allllo
ow
w ssu
urrffa
acce
ess tto
o cco
oo
oll b
be
effo
orre
e
sse
errv
viicciin
ng
g.. IIff sse
errv
viicciin
ng
g iiss n
ne
ecce
essssa
arry
y w
wh
hiille
e ssu
urrffa
acce
e
tte
em
mp
pe
erra
attu
urre
ess a
arre
e ssttiillll e
elle
ev
va
atte
ed
d,, y
yo
ou
u M
MU
US
ST
T p
pu
utt o
on
n
a
allll P
Pe
errsso
on
na
all P
Prro
otte
eccttiiv
ve
e E
Eq
qu
uiip
pm
me
en
ntt ((P
PP
PE
E))..
Weekly Maintenance
Perform the following maintenance procedure on a
weekly basis:
1. With the purge unit operating, check the purge tank
condensing activity by observing the liquid
refrigerant flow in the moisture-indicating sight
glass located in the liquid drain line immediately
after the filter drier canister. A lack of visible
refrigerant flow in the sight glass indicates one of
the following:
a. A pump-out cycle is necessary.
b. A problem exists with the purge heat transfer
circuit (such as the condensing unit, expansion
device, or purge evaporator coil).
c. A problem exists in the purge control
subsystem.
d. Refrigerant vapor from the chiller condenser is
blocked or restricted.
2. Check the moisture-indicator sight glass. Replace
the filter-drier core if moisture is indicated.
N
No
otte
e:: The need for frequent changes of the filter
drier could be an indication of significant
chiller air or tube leaks.
Semi-Annual Maintenance
Perform the following maintenance procedure on a
semi-annual basis:
1. Inspect the air-cooled condenser coil and clean as
needed. Clean the coil from the fan side using
compressed air or coil cleaner. A dirty coil will
reduce purge efficiency and capacity.
2. Inspect the purge tank and carbon tank insulation
for any damage or degradation. Make any needed
repairs to the insulation.
Annual Maintenance
Perform the following maintenance procedure on an
annual basis:
1. Semi-annual maintenance procedures described in
“Semi-Annual Maintenance,” p. 25
.
2. Purge system control checks described in
“Troubleshooting,” p. 28
.
3. Open the purge control panel and check all internal
components for such problems as corrosion,
terminal tightness, or signs of overheating.
4. Change the filter-drier assembly.
Replacing the Filter-Drier
Assembly
Following are maintenance instructions for filter-drier
assembly replacement; refer to
Figure 2, p. 9
, for the
location of this component.
1. At the Tracer® AdaptiView™ display, touch the
S
Se
ettttiin
ng
gss button to display the Settings screen.
Touch the P
Pu
urrg
ge
e S
Se
ettttiin
ng
gss button to display the
Purge Settings screen. Touch P
Pu
urrg
ge
e M
Mo
od
de
e to
display Purge Mode screen. From this screen, set
the mode to Stop.
2. Isolate the purge unit from the chiller. Close the
isolation valves on the purge vapor inlet and the
liquid return lines.
Содержание PRGD series
Страница 35: ...PRGD SVX01F EN 35 S Sc ch he em ma at ti ic c W Wi ir ri in ng g D Di ia ag gr ra am m ...
Страница 36: ...36 PRGD SVX01F EN S Sc ch he em ma at ti ic c W Wi ir ri in ng g D Di ia ag gr ra am m ...
Страница 37: ...PRGD SVX01F EN 37 N No ot te es s ...
Страница 38: ...38 PRGD SVX01F EN N No ot te es s ...
Страница 39: ...PRGD SVX01F EN 39 N No ot te es s ...