background image

WARNING

Follow EHS Policies!

Failure to follow instructions below could result in 
death or serious injury.

All Trane personnel must follow the company’s 
Environmental, Health and Safety (EHS) policies 
when performing work such as hot work, electrical, 
fall protection, lockout/tagout, refrigerant handling, 
etc. Where local regulations are more stringent than 
these policies, those regulations supersede these 
policies. 

Non-Trane personnel should always follow local 
regulations.

Introduction

RT-SVF55F-EN

Copyright

This document and the information in it are the property of 
Trane, and may not be used or reproduced in whole or in 
part without written permission. Trane reserves the right 
to revise this publication at any time, and to make changes 
to its content without obligation to notify any person of 
such revision or change.

Trademarks

All trademarks referenced in this document are the 
trademarks of their respective owners. 

Revision History

Updated the outdoor sound rating data in general data 
chapter.

Updated the T/YSC090H cooling cycle pressure curve 
(400 cfm/ton) in the pressure curve chapter.

Updated the T/YSC090H subcooling charging chart 
(320, 400 and 480 cfm/ton) in the subcooling charging 
chart chapter

Содержание Precedent TSC090H

Страница 1: ...fic knowledge and training Improperly installed adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in...

Страница 2: ...that is used in these service procedures In addition some states or municipalities may have additional requirements that must also be adhered to for responsible management of refrigerants Know the app...

Страница 3: ...ht This document and the information in it are the property of Trane and may not be used or reproduced in whole or in part without written permission Trane reserves the right to revise this publicatio...

Страница 4: ...4 RT SVF55F EN Table of Contents General Data 5 Performance Data 6 Evaporator Fan Performance 7 Pressure Curves 13 Subcooling Charging Chart 14 Refrigerant Circuit 17...

Страница 5: ...No Speeds CFM Motor HP Motor RPM 1 26 Direct 1 6400 0 70 1 100 Indoor Fan Type FC Centrifugal No Used Diameter in Width in Drive Type No Speeds RPM Motor HP Standard Oversized Motor Frame Size Standa...

Страница 6: ...ons Unit Model Number Fan Sheave 6 Turns Open 5 Turns Open 4 Turns Open 3 Turns Open 2 Turns Open 1 Turn Open Closed 7 5 T YSC090H AK56x1 N A 958 1022 1086 1150 1214 1278 Notes Factory set at 3 turns...

Страница 7: ...ive Kit or 2 hp Oversized Motor Drive 2400 1011 1 20 1041 1 28 1070 1 36 1099 1 44 1127 1 52 1153 1 60 1178 1 68 1203 1 76 1229 1 84 1252 1 92 2700 1051 1 45 1082 1 54 1111 1 63 1139 1 72 1166 1 81 11...

Страница 8: ...e 2400 1083 1 42 1119 1 52 1153 1 63 1185 1 73 1218 1 84 1249 1 95 1278 2 06 1307 2 16 1337 2 28 1364 2 38 2700 1120 1 67 1154 1 79 1188 1 91 1220 2 02 1252 2 14 1283 2 26 1313 2 39 1342 2 51 1370 2 6...

Страница 9: ...2400 1060 1 30 1091 1 39 1120 1 48 1150 1 57 1178 1 65 1204 1 74 1231 1 83 1256 1 91 1281 2 00 1304 2 09 2700 1109 1 58 1139 1 68 1167 1 77 1195 1 86 1223 1 96 1249 2 06 1275 2 16 1301 2 26 1325 2 35...

Страница 10: ...m bhp rpm bhp rpm bhp rpm bhp rpm bhp 3 hp Oversized Motor Drive 2400 1110 1 46 1140 1 55 1169 1 64 1198 1 73 1225 1 82 1251 1 91 1277 2 01 1301 2 10 1326 2 19 1350 2 28 2700 1165 1 78 1195 1 88 1223...

Страница 11: ...r Drive 2400 1074 1 37 1105 1 46 1136 1 55 1165 1 64 1194 1 73 1222 1 83 1250 1 92 1275 2 00 1301 2 10 1326 2 18 2700 1121 1 66 1151 1 76 1181 1 86 1211 1 97 1238 2 06 1266 2 17 1292 2 27 1318 2 37 13...

Страница 12: ...p rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 3 hp Oversized Motor Drive 2400 1132 1 58 1161 1 68 1189 1 77 1216 1 86 1242 1 95 1268 2 04 1293 2 13 1318 2 23 1342 2 33 1364 2 42 27...

Страница 13: ...Ton 150 200 250 300 350 400 450 500 550 600 650 100 110 120 130 140 150 160 170 180 190 Discharge Pressure Psig Suction Pressure Psig 68 57 F ID WB DB 74 62 F ID WB DB 86 72 F ID WB DB 80 67 F ID WB D...

Страница 14: ...ging Chart Figure 2 T YSC090H subcooling charging chart 320 cfm ton 0 100 200 300 400 500 600 700 45 55 65 75 85 95 105 115 125 135 Liquid Pressure Leaving OD Coil psig Liquid Temperature Leaving OD C...

Страница 15: ...harging chart 400 cfm ton 0 100 200 300 400 500 600 700 45 55 65 75 85 95 105 115 125 135 Liquid Pressure Leaving OD Coil psig Liquid Temperature Leaving OD Coil F Add charge Remove charge Subcooling...

Страница 16: ...charging chart 480cfm ton 0 100 200 300 400 500 600 700 45 55 65 75 85 95 105 115 125 135 Liquid Pressure Leaving OD Coil psig Liquid Temperature Leaving OD Coil F Add charge Remove charge Subcooling...

Страница 17: ...rcuit Figure 5 T YSC090H refrigerant circuit Compressor Filter Drier Air Air TXV Refrigerant Flow Cooling System 1 Service Valve High Pressure Control DLTS Low Pressure Control Service Valve Service V...

Страница 18: ......

Страница 19: ......

Страница 20: ...ications without notice We are committed to using environmentally conscious print practices Trane and American Standard create comfortable energy efficient indoor environments for commercial and resid...

Отзывы: