background image

11

SVU-MCXA_GB-EX (R410A)

- The  air-conditioner  will  accelerate

capacity up totally 20 minutes or until
room temperature is lower than 18ºC.

- When  TURBO  mode  completely

operates or is cancelled, “TURBO” will
be  disappeared  from  the  display  and
return  to  the  former  settings  before
TURBO mode.

- To cancel TURBO mode, either press

MODE button or select TURBO mode
and press MENU button again.

Note:

The  LCD  display  will  not  show  fan

speed and set temperature.

Fan speed and set temperature cannot

be  changed  while  TURBO  mode  is
selected.

In case of power failure, TURBO mode

will be automatically cancelled.

SLEEP Mode

SLEEP mode automatically and gradually
adjusts room temperature to provide great
comfort during your rest.
- Press MENU button and select SLEEP

mode by pressing either   or  .

- Press  MENU  button  again  to  confirm

SLEEP mode.   will be shown on the
display.

- After  one  hour  operation  of  SLEEP

mode, the unit will automatically raise
set temperature by 0.5ºC.

- After  one  and  half  hour  operation  of

SLEEP mode, the unit will automatically
raise  set  temperature  by  0.5ºC  again
and   on the display will disappear.

- To  cancel  SLEEP  mode,  either  press

MODE  button  or  select  SLEEP  mode
and press MENU button again.

Temperature

COOL MODE

23.0

22.5

22.0

0

Hour

2

1

HEAT Mode

- Press MENU button and select SLEEP

mode by pressing either   or  .

- Press MENU  button  again  to  confirm

SLEEP mode.   will be shown on the
display.

- After  one  hour  operation  of  SLEEP

mode, the unit will automatically reduce
set temperature by 0.5ºC.

- After  one  and  half  hour  operation  of

SLEEP mode, the unit will automatically
reduce set temperature by 0.5ºC again
and   on the display will disappear.

- To  cancel  SLEEP  mode,  either  press

MODE  button  or  select  SLEEP  mode
and press MENU button again.

E

D

O

M

 

T

A

E

H

E

R

U

T

A

R

E

P

M

E

T

 

M

O

O

R

26.0

25.5

25.0

0

1

2

HOUR

Note:

Set temperature shown on the display

still  show  the  setting  without  1ºC
added/reduced  but  it  will  plus/minus
1ºC in the memory.

 will disappear from the LCD display

when  SLEEP  mode  completely
operates, after one and half hours, or
is cancelled.

In case of power failure, SLEEP mode

will be automatically cancelled.

ECONO Mode

ECONO  mode  drastically  saves  energy
with  high  efficient  cooling  capacity  in
COOL  mode  by  reducing  power
consumption. With this simply mode, the
user  can  easily  get  energy  saving  and
comfort.
- Press MENU button and select ECONO

mode by pressing either   or  .

- Press  MENU  button  again  to  confirm

ECONO mode. “ECONO” will be shown
on the display.

- The air-conditioner will operates at low

fan  speed  and  raise  temperature  by
1ºC from set temperature.

- To cancel ECONO mode, either press

MODE button or select ECONO mode
and press MENU button again.

0

1

2

3

4

5

6

7

8

9

10

11

12

START

Normal

Econo

HOUR

SET  POINT

ECONO MODE (COOLING)

The unit will operate at low fan speed and raise temperature by 1ºC 
from set temperature. It will automatically return to normal operation 
when the air-conditioner is switched off and on again.

+1ºC

+2ºC

–2ºC

–1ºC

Note:

ECONO mode operates only in COOL

mode and automatically operates when
air-conditioner is closed without exiting
or canceling ECONO mode.

Fan  speed  cannot  be  changed  while

ECONO mode is selected.

SWEEP Function

SWEEP function swiftly distributes air flow
and helps provide better air circulation in
the  room  with  comfortable  cooling  or
heating.
- Press MENU button and select SWEEP

function by pressing either   or  .

- Press  MENU  button  again  to  confirm

SWEEP function.   will be shown on
the display.

- The  air-conditioner  will  automatically

sweep  the  supply  air  grille  back  and
forth.

- To  cancel  SWEEP  function,  select

SWEEP  function  and  press  MENU
button again.

Note:

The supply air grille will be fully closed

when the unit is off.

The supply air grille will be fully opened

when the unit is on.

The supply air grille will automatically

stop sweeping when compressor stops
operating  and  reactivate  SWEEP
function  once  compressor  becomes
operating.

SWEEP function is available only from

MCX512-530GB5 and MCX512-536 for
standard models and residential series.

ºC/ºF Toggle

The optional feature offers you to change
the temperature display from ºC to ºF or
from ºF to ºC.
- Press and hold both   and   button

for 5 seconds to change temperature
display.

Digital Wired Control

SVU-MCXA_GB-EX (R410A).indd

21/11/2017, 11:27 AM

11

Содержание NEW STYLUS MCX Series

Страница 1: ...MCXB 60 GB 60 Hz Models Cooling Only MCXA 12 G1 MCXA 18 G1 MCXA 24 G1 MCXA 30 G1 MCXA 36 G1 MCXB 42 G1 MCXB 48 G1 MCXB 60 G1 60 Hz Models Cooling Heating MCXA 12 G1E MCXA 18 G1F MCXA 24 G1B MCXA 30 G...

Страница 2: ...it before signing the delivery note Specify any damage of the unit on the delivery note and send a registered letter of protest to the last carrier of the goods within 72 hours of delivery Notify the...

Страница 3: ...i t a r e p O l o r t n o C Wireless Remote Control 5 9 l o r t n o C d e r i W l a t i g i D 2 1 n o i t a r e p O m e t s y S 3 1 s n o i t u a c e r P y t e f a S 4 1 e c n a n e t n i a M 5 1 g n...

Страница 4: ...s when compressor is operated One Touch Control Switch A This button is used for adjusting operation without remote control unit Cooling Heating Four lamps on the unit show operating status 1 FAN Lamp...

Страница 5: ...was set 12 LIGHT Button Press this button to turn on the LCD light 13 POWERCOOL Button Press this button to accelerate capacity up 14 ECONO Button Press this button to save energy Wireless Remote Con...

Страница 6: ...espectively Note In AUTO mode the system will automatically switch between COOL mode and HEAT mode to maintain equally room temperature and set temperature CLOCK Setting Press CLOCK button to set cloc...

Страница 7: ...er or button to set the desired minute Press OFF TIMER button again to confirm minute setting Hour and minute number will stop blinking The unit is now standby for stopping air conditioner automatical...

Страница 8: ...conditioner will automatically sweep the supply air grille back and forth To cancel SWEEP function press SWEEP or LOUVER button again Note The supply air grille will be fully closed when the unit is...

Страница 9: ...elected Press either or button to set the desired temperature between 15 C to 30 C Press FAN SPEED button to select the desired fan speed level and the display will show Auto Low Medium High A Auto Lo...

Страница 10: ...and minute number will be blinking Press either or button to set the desired minute Press MENU button again to confirm minute setting Hour and minute number will stop blinking The unit is now standby...

Страница 11: ...lf hours or is cancelled In case of power failure SLEEP mode will be automatically cancelled ECONO Mode ECONO mode drastically saves energy with high efficient cooling capacity in COOL mode by reducin...

Страница 12: ...iscomfort and make the room temperature uneven Adjust Air Flow Direction with sweep option The sweep motor will sweep the supply air grille upward and downward For left and right air flow the supply a...

Страница 13: ...ce the fan revolves at high speed it is very dangerous Be especially careful with children Be sure to always have the air filter properly installed when the unit is operated Otherwise dirt can get int...

Страница 14: ...cleaning the front panel or paint may peel off or it may become deformed or damaged 3 Maintenance before prolonged idle period Operate the fan for about half a day to dry the inside of the unit Stop...

Страница 15: ...the air conditioner Troubleshooting Cooling is insufficient Check whether the air filter is clogged Clean it Check whether the thermostat setting is too high Set the thermostat to lower temperature Ch...

Страница 16: ...ta improvement and reserves the right to change design and specifications without notice SVU MCXA_GB EX R410A indd 21 11 2017 11 27 AM 16 http www tranethailand com A Business of American Standard Com...

Отзывы: