General Information

This Installation Manual is given as a guide to good practice in the installation by the installer of 
MCX mini-split system. Installation procedures should be performed in the sequence that they 
appear in this manual.

For installing the unit to operate properly and reliably, it must be installed in accordance with 
these instructions. Also, the services of a qualified service technician should be employed, 
through the maintenance contract with a reputable service company.

Read these Installation Instructions completely before installing the air conditioning system.

About this Manual

Warnings and Cautions appear at appropriate places in this Instruction Manual. Your personal 
safety and the proper operation of this machine depend upon the strict observance of these 
precautions.

The Trane Company assumes no liability for installations or servicing performed by unqualified 
personnel. All phases of the installation of this air conditioning system must conform to all 
national, provincial, state and local codes.

 

WARNING

Grounding Required!

Follow proper local and state electrical code on requirements for grounding. Failure to 
follow code could result in death or serious injury.

About the Unit

These MCX/MWX units are assembled, pressure tested, dehydrated, charged and run tested 
before shipment. They are charged with nitrogen, and could be used in applications with R-22 
and R-410A refrigerant. For further information on refrigerant and piping connections refer to the 
outdoor unit manual or contact your Trane local office.

The information contained in this manual applies to MCX/MWX units are designed to operate in 
cooling mode only (MCX) and in cooling or heating modes (MWX).

Trane MCX/MWX series of mini-split systems offer three styles of installation: floor, low wall and 
under ceiling with both LCD wireless remote control or wired control. Trane MCX/MWX series 
provide flexibility and savings.

Note:

For model MCX/MWX 042, MCX/MWX 048 and MCX/MWX 060, there are only two styles 
of installation: under ceiling and low wall.

NOTICE:

 

Warnings and Cautions appear at appropriate sections throughout this 

literature. Read these carefully.

 

WARNING:

 Indicates a potentially hazardous situation which, if not avoided, could 

result in death or serious injury.

CAUTION:

 Indicates a potentially hazardous situation which, if not avoided, could 

result in minor or moderate injury. It may also be used to alert against unsafe practices.

NOTICE

:

 Indicates a situation that could result in equipment or property-damage only 

accidents.

Содержание MCX042 G1

Страница 1: ...2 G1 MCX512G1E MWX512 G1 MCX518 G1 MCX518G1F MWX518 G1 MCX524 G1 MCX524G1B MWX524 G1 MCX530 G1 MCX530G1H MWX530 G1 MCX536 G1 MCX536G1J MWX536 G1 MCX042 G1 MCX042G1J MWX042 G1 MCX048 G1 MCX048G1K MWX04...

Страница 2: ...ailure to follow code could result in death or serious injury About the Unit These MCX MWX units are assembled pressure tested dehydrated charged and run tested before shipment They are charged with n...

Страница 3: ...ating limits are exceeded or if the control system or the electrical wiring is modified Damage due to inappropriate installation lack of knowledge or failure to comply with the manufacturer s instruct...

Страница 4: ...Preparation of Units 6 Unit installation 8 Indoor Unit 8 Outdoor Unit 10 Connection of Refrigerant Tubing 11 Condensate Drain Piping 16 Electrical Installation 17 Remote Control Installation 18 Typic...

Страница 5: ...eiling and low wall Typical Installation Ceiling mounted Outdoor unit Indoor unit Floor mounted Return air grille contains air filter Refrigerant tubing wiring Drain Returnair grille contains air filt...

Страница 6: ...nsideration must be given to assure an unobstructed flow of supply and return air 4 Refrigerant tubes between indoor and outdoor units should be as short as possible 5 Length of the condensate drain h...

Страница 7: ...eat sources as this may affect performance Do not allow outside air to directly enter unit or condensate may form at the unit s discharge Note For MCX MWX 042 060 the unit should be installed over the...

Страница 8: ...t no pipes or studs are directly behind the place to be cut Avoid areas where electrical wiring or conduits are located 3 Place the unit on a solid and level foundation 4 Tubing wiring through and dra...

Страница 9: ...ont Figure 8 Then push down on the side panel front and pull up Figure 9 Note A 0 49 x 1 575 4 SLOT Mounting hole 12 5 mm 40 0 mm Figure 4 Figure 5 Figure 6 Unit Size B MCX MWX 512 518 36 2 920 MCX MW...

Страница 10: ...not level Failure to properly lift unit could result in death or serious injury or possible equipment or property only damage 8 Place or hang the unit at the selected position 9 Replace both right and...

Страница 11: ...erant line connections are flared Installation brazing leak testing and evacuation of refrigerant lines are covered in the Installer Manual packaged with the outdoor unit Read the instructions before...

Страница 12: ...not to crush it To prevent crushing of the tube bend it gently and do not bend the tube at a radius curvature of less than 100 mm 6 If the copper tube is bent or pulled too often it will become stiff...

Страница 13: ...orque with torque wrench and adjustable wrench Figure 18 11 Repeat the process above for the remaining line Figure 6 Figure 7 Table 1 Flare Nut Tightening Torque Flare Nut Piping Size Tightening Torqu...

Страница 14: ...rarily cap off tubes if the refrigerant line connections are to be made later WARNING Hazard of Explosion and Deadly Gases Never solder braze or weld on refrigerant lines or any unit components that a...

Страница 15: ...the copper tube before brazing a copper tube to a solder coupling or a copper tube to an expanded tube do not forget to keep them tight as shown in Figure 21 22 10 Use a dry nitrogen purge and brazin...

Страница 16: ...loor mounted position When the drain hose is placed in the room insulate the hose with foam polyethylene to avoid damage to the ceiling or furniture After completing installation of refrigerant lines...

Страница 17: ...ing compressor motors or moving parts The manufacturer will accept no responsibility for problems caused by unauthorized changes in the internal wiring Connect the wiring firmly Electrical Connections...

Страница 18: ...Do not place in a confined space 4 Attach the remote control holder as shown in Figure 25 Remote Control Installation Figure 1 Dimension Wired remote control MCX units only Mounting Bracket TEMP MENU...

Страница 19: ...1 FREEZE SENSOR LOCATED ON EVAPORATOR COIL 2 TEMPERATURE SENSOR LOCATED IN RETURN AIR STREAM SWEEP MOTOR OPTION ROOM STEPPER TOP STEPPER FRONT DISPLAY WIRELESS REMOTE CONTROLLER POWER SUPPLY 220 240V...

Страница 20: ...RED BLK BLU RED INFRARED RECEIVER P17 P16 BLK RED J2 J1 WHT GRN YL BLK BLU RED BLOWER MOTOR BRW WHT WIRELESS REMOTE CONTROLLER POWER SUPPLY 220 240VAC 1PH 60Hz WIRING TO GROUNDING SYSTEM 200 240 VAC C...

Страница 21: ...LOW MED HI NEUTRAL LINE P3 P7 P6 P5 P4 P2 P1 WHT RED RED BLK BLU RED YL P17 P16 BLK RED J2 J1 WIRE DISPLAY BLK BLU RED YL WHT BRW WHT BLOWER MOTOR N C1 C2 L POWER SUPPLY 220 240VAC 1PH 60Hz WIRING TO...

Страница 22: ...WIRE DISPLAY P3 P6 P5 P4 P2 P1 WHT RED RED BLK BLU RED P17 P16 BLK RED J1 WHT BRW WHT BLK BLU RED BLOWER MOTOR BLU BLUE BLK BLACK RED RED WHT WHITE GRN GREEN YL YELLOW BR BROWN COIL FIELD WIRING FACTO...

Страница 23: ...MS SVN15B EN 23 Typical Wiring Diagram Figure 5 MCX512 536G1 60 Hz Indoor Unit Cooling Heater with Wireless Controller Basic model 3 speed...

Страница 24: ...24 MS SVN15B EN Typical Wiring Diagram Figure 6 MCX042 060G1 60 Hz Indoor Unit Cooling Heater with Wireless Controller Basic model 3 speed...

Страница 25: ...MS SVN15B EN 25 Typical Wiring Diagram Figure 7 MWX 512 536 G1 60 Hz Indoor Unit Heat Pump Model with Wireless Controller Residential model 4 speed SWEEP MOTOR P20 P19 STEPPER TOP STEPPER FRONT...

Страница 26: ...26 MS SVN15B EN Typical Wiring Diagram Figure 8 MWX 042 060 G1 60 Hz Indoor Unit Heat Pump Model with Wireless Controller Basic model 3 speed...

Страница 27: ...Suction Connections IN mm IN mm Each MCX MWX 512G1 MCX MWX 518G1 1 4 6 4 1 2 12 7 Flared 42 28 1074 0 34 61 879 0 4 MCX MWX 524G1 3 8 9 5 5 8 15 9 Flared 51 13 1324 0 44 45 1129 0 4 MCX MWX 530G1 3 8...

Страница 28: ...Type A B C D Liquid Suction Connections IN mm IN mm Each IN mm MCX MWX 042G1 MCX MWX 048G1 3 8 9 5 3 8 9 5 7 8 22 2 1 1 8 28 6 Brazed Brazed 71 81 1824 0 64 13 1629 0 8 15 76 400 MCX MWX 060G1 3 8 9...

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ...r e mail us at comfort trane com Literature Order Number MS SVN15B EN Date April 2009 Supersedes MS SVN15B EN February 2009 Trane has a policy of continuous product and product data improvement and re...

Отзывы: