VI. PERIODIC PREVENTATIVE MAINTENANCE

NOTE: Periodic inspection and preventive maintenance of your total
heating system is important for efficient and safe operation. Your heating
dealer should perform humidifier service at the same time.

All models are equipped with an in-line water strainer and orifice as
shown below. These parts should be inspected and cleaned periodically to
assure continued proper humidifier performance.

*M

A

Y

B

E

“A

O

R

“T

M

O

D

E

LS

*H

U

M

D

20

0A

B

M

00

B

,

*H

U

M

D

30

0A

B

A

00

B

MAINTENANCE INSTRUCTIONS for HUMIDIFIER

MODELS *HUMD200ABM00B, *HUMD300ABA00B

- 8 -

- 9 -

WARNING

Disconnect Electrical Power and Shut Off Water

Supply Before Servicing. Failure to follow this warning may cause
property damage, personal injury or death.

CAUTION

Turn Humidifier Control to “OFF” or lowest

setting before servicing. Sudden operation may cause personal injury
or property damage.

CAUTION

Turn Humidifier Control to “OFF” or lowest setting before servicing.

Sudden operation may cause personal injury or property damage.

1. Disconnect electrical power to the furnace and

shut off water supply.

2. Disconnect the water line at the inlet

compression nut.

3. Remove the in-line strainer from inside the inlet

side of the valve by using a small nail or wire.

4. Flush the in-line strainer clean or replace with a

new strainer, Service Part No. SRA00859.

5. Reconnect the inlet water line.

Double Wrench

to Prevent Leaking.

6. Disconnect the water feed tube at the outlet

compression nut.

7. Inspect the water feed tube (plastic only) by

gently flexing it and looking for cracks or signs of
wear. Replace tube if it is cracked, brittle, or has
been damaged.

8. Remove the orifice from the copper or plastic

water feed tube and make sure this small
opening is unplugged.

9. Replace the orifice and reconnect the water feed tube.

Double Wrench to

Prevent Leaking.

10. Remove the drain line from the bottom of the humidifier. If applicable, flex it to

loosen any mineral deposits or blockages. Flush the drain line with water under
pressure to clear it of any debris, and slip it back onto the drain fitting. If drain
line does not clean properly, replace it. Inspect the drain line to make sure it
has a constant downward slope and is not flattened or blocked.

11. Turn on water supply and reconnect electrical power to the furnace.

WATER LINE INSPECTION AND SERVICE INSTRUCTIONS

INLET
COMPRESSION
NUT

INLET

SOLENOID 
VALVE 

ORIFICE

OUTLET
COMPRESSION 
NUT

IN-LINE
STRAINER

WATER
FEED TUBE

90-1053

9

6

3

7

8

5

2

1

4

1. Note Humidifier Control setting and turn dial to the “OFF” position.

2. Turn off water supply. Turn the integral bypass damper (3) to the SUMMER position.

3. Press the tabs in the latches on the top and bottom of front cover (1) and pull cover off base

with both hands. Set aside.

4. Carefully pull the plastic feed tube (2) out of the distribution tray (5) at the top of the

evaporative assembly (4). Pull this assembly out by grasping at top and tipping out.

5. Unsnap the distribution tray (5) from the scale control insert (8). Lightly scrape out or brush

off any mineral deposits, being careful not to stretch or loosen the synthetic fabric liner.
Soaking the tray in vinegar or a lime-removing agent is helpful when trying to remove
stubborn mineral deposits.

6. Slide the Humidifier Pad (7) out from the scale control insert (8). Clean the scale control

insert of mineral deposits. Replace the Humidifier Pad annually with a BAYPAD01A1010A
Humidifier Pad for Model *HUMD200ABM00B and BAYPAD02A1310A Humidifier Pad for
Model *HUMD300ABA00B. Slide the Humidifier Pad back into the scale control insert with
the colored spot up and snap the distribution tray (5) back into place.

7. Inspect the plastic feed tube (2) by gently flexing it and looking for cracks or signs of wear.

Replace tube if it is cracked, brittle, or has been damaged.

8. Reinstall the evaporative assembly (4) into the humidifier by fitting its drain into the round

receptacle at the base of the humidifier. Push the assembly in at the top until it snaps into
place. Push the end of the feed tube (2) back firmly into the distribution tray and replace the
front cover (1).

9. Remove the drain line (9) from the bottom of the humidifier. If applicable, flex it to loosen any

mineral deposits or blockage. Then flush it with water under pressure. If it does not properly
clear, replace it. Slip drain line back onto the drain fitting. Make sure the drain line has a
constant downward slope and is not flattened or blocked.

10. Turn on the water supply. Return integral bypass damper (3) to appropriate position.

11. Check system operation:

Manual Humidifier Control (*HUMD200ABM00B):

With the furnace blower operating and

the furnace calling for heat, turn up Control and check system operation.

Automatic Humidifier Control (*HUMD300ABA00B):

(Automatic or Manual mode) Check

system operation and reset Change Humidifier Pad indicator by setting the knob to
“Test/Reset”. With furnace blower operating and furnace calling for heat, humidifier will
operate for one minute. DO NOT LEAVE IN TEST MODE AS HUMIDIFIER WILL NOT OPERATE.

12. Set Humidifier Control to its original position.

1. Front Cover

2. Feed Tube

3. Integral Bypass

Damper

4. Evaporative

Assembly

5. Distribution Tray

6. “V” Notches

7. Humidifier Pad

8. Scale Control Insert

9. Drain Line

90-1169

Содержание HUMD200ABM00B

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS USE AND CARE MANUAL Includes Safety Operating Instructions and Warranty Information For Models HUMD200ABM00B HUMD300ABA00B HUMD500APA00B May be A or T ...

Страница 2: ...e winter your comfort relies on two things the perfect temperature and the perfect amount of moisture Your new humidifier will provide your home with the recommended indoor relative humidity to ensure your comfort all winter long INTRODUCTION TABLE OF CONTENTS WARNING ELECTRICAL SHOCK HAZARD Disconnect Electrical Power and Shut Off Water Supply Before Servicing Failure to follow this warning may c...

Страница 3: ... FIGURE A Your new humidifier has been installed to operate in conjunction with your furnace When the Humidifier Control calls for humidity and the furnace blower is operating water flows to the distribution tray located at the top of the humidifier The water is evenly distributed across the width of the tray and over the Humidifier Pad Dry hot air is moved through this moisture laden Humidifier P...

Страница 4: ...ome with the possibility of damage resulting Outside Temperature Recommended RH 40 F 45 30 F 40 20 F 35 10 F 30 0 F 25 10 F 20 20 F 15 The Humidifier Control is a precision instrument that can be used to determine the RH accurately in your home during the winter Turn the dial to the lower setting then reverse the dial direction slowly until a click is heard At this point read the RH on the dial Th...

Страница 5: ... outside temperature Additional Information Be sure to keep fireplace dampers closed when not in use They provide an excellent escape route for heat as well as humidity Humidity is lost at an even faster rate than heat because water vapor tends to seek its own level and your humidifier would not be able to replace it even when running at full capacity On occasion indoor moisture producing activiti...

Страница 6: ...l to the OFF position 2 Turn off water supply Turn the integral bypass damper 3 to the SUMMER position 3 Press the tabs in the latches on the top and bottom of front cover 1 and pull cover off base with both hands Set aside 4 Carefully pull the plastic feed tube 2 out of the distribution tray 5 at the top of the evaporative assembly 4 Pull this assembly out by grasping at top and tipping out 5 Uns...

Страница 7: ...ribution tray 6 Slide the Humidifier Pad 6 out from the scale control insert 7 Clean the scale control insert of mineral deposits Replace Humidifier Pad annually with a BAYPAD02A1310A Humidifier Pad Slide the Humidifier Pad back into the scale control insert with the colored spot up and snap the distribution tray 4 back into place 7 Inspect the plastic feed tube by gently flexing it and looking fo...

Страница 8: ...60 days after the Commencement Date to receive the registered limited warranty terms To register online go to http www trane com Residential Trane Owners Warranty Information or http www americanstandardair com sevicesupport pages warranty aspx and click Begin Online Registration If a Purchaser does not register within this stated time period the base limited warranty terms shall apply ELIGIBILITY...

Страница 9: ...RD ZDAMPSM ZDAMPBM ZDAMPRR Base Limited Warranty Period five 5 years Registered Limited Warranty Period ten 10 years HUMIDIFIERS HUMD200 HUMD300 HUMD500 Base Limited Warranty Period five 5 years Registered Limited Warranty Period ten 10 years ENERGY RECOVERY VENTILATOR ERV ERVR100 ERVR200 ERVR300 Base Limited Warranty Period five 5 years Registered Limited Warranty Period ten 10 years AIR CLEANERS...

Отзывы: