MUA-SVX006B-EN
25
IIm
mp
po
orrtta
an
ntt:: Unit installation for use with propane (bottled) gas must be made by a qualified LP
gas dealer or installer. He will insure proper joint compounds are used for making
pipe connections; that air is purged from lines; that a thorough test is made for leaks
before operating the unit; and that it is properly connected to propane gas supply
system.
Modulating Gas Control (Optional)*
E
Elle
eccttrro
on
niicc:: On units equipped with electronic modulating control, follow control manufacturer’s
installation instructions for sensing of outlet air temperature.
N
No
otte
e:: *Also refer to the Separated Combustion Indoor Duct Furnace Installation Manual supplied
with your unit.
Electrical Connections
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e d
diisscco
on
nn
ne
eccttss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w
p
prro
op
pe
err llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y
e
en
ne
errg
giizze
ed
d.. V
Ve
erriiffy
y tth
ha
att n
no
o p
po
ow
we
err iiss p
prre
esse
en
ntt w
wiitth
h a
a v
vo
ollttm
me
ette
err..
•
All electrical connections must conform to: the latest edition of ANSI/NFPA No. 70, National
Electrical Code, and applicable local codes. In Canada, to the Canadian Electrical Code, Part I
CSA Standard C22.1.
W
WA
AR
RN
NIIN
NG
G
R
Riisskk o
off E
Elle
eccttrro
occu
uttiio
on
n!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w iin
nssttrru
uccttiio
on
nss b
be
ello
ow
w cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
DO
O N
NO
OT
T u
usse
e a
an
ny
y tto
oo
ollss ((ii..e
e.. ssccrre
ew
wd
drriiv
ve
err,, p
plliie
errss,, e
ettcc..)) a
accrro
ossss tth
he
e tte
errm
miin
na
allss tto
o cch
he
ecckk ffo
orr
p
po
ow
we
err.. Y
Yo
ou
u M
MU
US
ST
T u
usse
e a
a v
vo
ollttm
me
ette
err..
•
Single furnace make-up air packaged units are wired at the factory and are ready to be
connected. Multiple furnace make-up air units are shipped in two parts, the air handler
section and the furnace section. After mounting the two sections and installing the flexible
duct connector, connect the free end of the flexible conduits from the air handler section to
the junction box on the duct furnace. Each wire has a distinctive marking. Connect each wire
to its respectively marked terminal in the duct furnace junction box. See
.
Actual unit wiring will differ according to the options chosen. Each unit is shipped with its
own wiring diagram; refer to this wiring diagram for all electrical connections to the unit.
•
All line voltage and thermostat connections are made in the Electrical Cabinet (See
). Line voltage connections are made at the High Voltage Terminal Block. Thermostat
connections are made at the Main Connection Board (See
•
Locate the thermostat in accordance with the instructions supplied with the thermostat. All
field wiring must have a minimum temperature rating of 185°F (85°C). Control wiring shall be
a minimum of 18 gauge wire size. Control wiring must be sized for length of run.
•
Locate line voltage disconnect box per local codes. If mounting the disconnect box to the unit,
never mount it to a unit access panel. Possible locations include the front of the blower or
filter section (See
). Electrical conduit must be routed so as not to interfere
with removal of any access panel.
Содержание GXAA
Страница 16: ...16 MUA SVX006B EN Figure 7 Flexible Connector Kit Install I In ns st ta al ll la at ti io on n...
Страница 17: ...MUA SVX006B EN 17 Figure 8 Flexible Connector Kit Install I In ns st ta al ll la at ti io on n...
Страница 18: ...18 MUA SVX006B EN Figure 9 Flexible Connector Kit Install I In ns st ta al ll la at ti io on n...
Страница 19: ...MUA SVX006B EN 19 Figure 10 Flexible Connector Kit Install I In ns st ta al ll la at ti io on n...
Страница 48: ...48 MUA SVX006B EN Dimensional Data Arrangements Indoor Arrangement A Capacity 50 80...
Страница 55: ...MUA SVX006B EN 55 Motor Electric Data Table 4 Full Load Current in Amperes...
Страница 58: ...58 MUA SVX006B EN Coil Cabinet Dimensional Data Figure 25 Coil Cabinet Dimensional Data...
Страница 62: ...62 MUA SVX006B EN Gas Equipment Start Up...
Страница 63: ...MUA SVX006B EN 63 N No ot te es s...