2
Service Facts
X343070P08
PRODUCT SPECIFICATIONS
1
MODEL
TYPE
RATINGS
2
1st Stage Input BTUH
1st Stage Capacity BTUH (ICS)
3
2nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS)
3
AFUE
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGER
Type -Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz
4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
*DH2B060A9V3VA
Downflow / Horizontal
39,000
37,000
60,000
57,000
95
35 - 65
DIRECT
10 x 8
1
Variable
See Fan Performance Table
1/2
Variable
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Yes
High Velocity
2 - 14x20 - 1 in.
2 Round
Aluminized Steel - Type I
20
3 — 45
3 — 56
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
3
115/1/60
11.1
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
160/ 146
*UH2D120A9V5VA
Upflow / Horizontal
78,000
75,426
120,000
116,040
96.7
40 - 70
DIRECT
10 x 10
1
Variable
See Fan Performance Table
1
Variable
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Yes
High Velocity
1 - 24x25 - 1 in.
3 Round
Aluminized Steel - Type I
20
6 — 45
6 — 56
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
6
115/1/60
15.2
20
1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
206 / 193
1
Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3.
2
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3
Based on U.S. government standard tests.
4
The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
*UH2C100A9V5VA
Upflow / Horizontal
65,000
62,855
100,000
96,700
96.7
35 - 65
DIRECT
11 x 10
1
Variable
See Fan Performance Table
1
Variable
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Yes
High Velocity
1 - 20x25 - 1 in.
3 Round
Aluminized Steel - Type I
20
5 — 45
5 — 56
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
5
115/1/60
16.3
20
1/2
H x W x D
41-3/4 x 23 x 30-1/2
199 / 187
Содержание *DH2B060A9V3VA
Страница 8: ...8 Service Facts X343070P08 UH2 WIRING DIAGRAM From drawing D344303 ...
Страница 9: ...9 Service Facts X343070P08 UH2 SCHEMATIC DIAGRAM2 From drawing D344303 ...
Страница 10: ...10 Service Facts X343070P08 DH2 WIRING DIAGRAM From drawing D344304 ...
Страница 11: ...11 Service Facts X343070P08 DH2 SCHEMATIC DIAGRAM From drawing D344304 ...
Страница 41: ...41 Service Facts X343070P08 ...