Service & Maintenance
Monthly Maintenance
Before completing the following checks, turn all system control circuit
switches to the “Off” position.
“Open” the main power disconnect switches for the Condensing Unit and all
system support equipment. “lock” the disconnect switches in the “Off”
position before removing any access panels.
WARNING
Hazardous Voltage!
Disconnect all electric power, including remote disconnects before
servicing. Follow proper lockout/tagout procedures to ensure the
power can not be inadvertently energized. Failure to disconnect power
before servicing could result in death or serious injury.
Table 15 — Condenser Coil Data
Coil Cleaning
Regular coil maintenance, including annual cleaning, enhances the unit's
operating efficiency by minimizing:
• compressor head pressure and amperage draw; evaporator water
carryover; fan brake horsepower, due to increase static pressure
losses; airflow reduction.
At least once each year, or more often if the unit is located in a “dirty”
environment, clean the evaporator and condenser coils using the
instructions outlined below. Be sure to follow these instructions as closely as
possible to avoid damaging the coils.
To clean refrigerant coils, use a soft brush and a sprayer (either a garden
pump-up type or a high-pressure sprayer). A high-quality detergent is also
required; suggested brands include “SPREX A.C.”, “OAKITE 161", “OAKITE
166" and “COILOX”. If the detergent selected is strongly alkaline (ph value
exceeds 8.5), add an inhibitor.
1. Remove enough panels from the unit to gain access to the coil.
Unit
Size
Number
of
Coils
Coil Fin
Configuration
Tube
Diameter
Coil
Rows
Fins
per
Foot
Coil
Size
(Inches)
Subcooler
Size
(Inches)
Tube
Type
C25
2
Slit Fin
0.375”
3
144
45 x 71
35 x 71
14 x 71
Smooth
C40
2
Slit Fin
0.375”
3
144
56 x 70
9 x 70
Smooth
C60
2
Slit Fin
0.375”
4
144
57 x 96
9 x 96
Smooth
Содержание CSRA025FAF0
Страница 6: ...6 CSRA SVX02A EN General Information Figure 1a Model Number Description...
Страница 18: ...18 CSRA SVX02A EN Installation Figure 4a C25 Ton Unit Dimensional Data Recommended Clearances...
Страница 19: ...CSRA SVX02A EN 19 Installation Figure 4b C40 Ton Unit Dimensional Data Recommended Clearances...
Страница 20: ...20 CSRA SVX02A EN Installation Figure 4c C60 Ton Unit Dimensional Data Recommended Clearances...
Страница 47: ...CSRA SVX02A EN 47 Installation Figure 20A Typical Field Control Connections Diagram...
Страница 48: ...48 CSRA SVX02A EN Installation Figure 20B Typical GBAS 0 5 Volt Connections Diagram...
Страница 49: ...CSRA SVX02A EN 49 Installation Field Connection Diagram Notes for all System Control Options...
Страница 65: ...CSRA SVX02A EN 65 System Start Up Figure 22 Condenser Fan Locations...